Parameter
Position control by vector control
FR-A700 EC
6 - 131
6.5.2
Conditional position feed function by contact input
(Pr. 419, Pr. 464 to Pr. 494)
Inputting the number of pulses (positions) in the parameters and setting multi-speed (refer to
page 6-132) and forward (reverse) commands enable position control. The motor does not
return to the home position with this conditional position feed function.
Pr.
No.
Name
Initial
Value
Setting Range
Description
Parameters referred to
Refer to
Section
419
Position command
source selection
0
0
Conditional position control func-
tion by contact input. (position
command by parameter settings)
20
29
Acceleration/decel-
eration reference
frequency
Acceleration/decel-
eration pattern
selection
2
Conditional pulse train position
command by inverter pulse train
input
464
Digital position
control sudden stop
deceleration time
0 s
0–360,0 s
Set the time until the inverter stops
when the forward rotation (reverse
rotation) command is turned off
with the position feed forward func-
tion.
Vector
Vector
Vector
Summary of Contents for FR-A700 EC
Page 2: ......
Page 4: ......
Page 24: ...Description of the Case Product Checking and Part Identification 1 4 ...
Page 38: ...Enclosure design Installation 2 14 ...
Page 774: ...Specifications FR A 740 01800 to 12120 Appendix A 4 ...
Page 820: ...Parameter list with instruction codes Appendix A 50 ...
Page 825: ......