23
Electrical Installation
(continued)
SW1
SW1-1
Boiler
WITHOUT Boiler
WITH Boiler
OFF
OFF
SW1-2
Maximum HP water temperature
55ºC
60ºC
ON
ON
SW1-3
DHW tank
WITHOUT DHW tank
WITH DHW tank
ON
ON
SW1-4
Immersion heater
WITHOUT Immersion WITH Immersion
ON
ON
heater
heater
SW1-5
Booster heater
WITHOUT Boost
WITH Boost
OFF
OFF
heater
heater
SW1-6
Booster heater function
For heating only
For heating and DHW
ON
ON
SW1-7
Outdoor unit type
Split type
Packaged type
ON
ON
SW1-8
Wireless controller
WITHOUT Wireless
WITH Wireless
OFF
OFF
controller
controller
SW2
SW2-1
Room thermostat 1 (IN1)
Zone 1 operation stop Zone 1 operation stop OFF
OFF
logic change
at thermostat close
at thermostat open
SW2-2
Flow switch 1 (IN2) logic change
Failure detection
Failure detection
OFF
OFF
at close
at open
SW2-3
Booster heater capacity restriction Inactive
Active
OFF
OFF
SW2-4
Cooling mode function
Inactive
Active
OFF
OFF
SW2-5
Automatic switch to backup
Inactive
Active *
1
OFF
OFF
heat source (O/U error)
SW2-6
Mixing tank (2 zone)
WITHOUT Mixing
WITH Mixing
OFF
ON*
4
SW2-7
2 zone control
Inactive
Active
OFF
ON*
4
SW2-8
-
-
-
OFF
OFF
SW3
SW3-1
Room thermostat 2 input (IN6)
Zone 2 operation stop Zone 2 operation stop OFF
OFF
logic change
at thermostat close
at thermostat open
SW3-2
Flow switch 2 (IN3) logic change
Failure detection
Failure detection
OFF
OFF
at close
at open
SW3-3
Flow switch 3 (IN7) logic change
Failure detection
Failure detection
OFF
OFF
at close
at open
SW3-4
Cooling operation in zone 2
Not in use
In use
OFF
OFF
SW3-5
Heating mode function
Inactive
Active
OFF
OFF
SW3-6
-
-
-
OFF
OFF
SW3-7
-
-
-
OFF
OFF
SW3-8
-
-
-
OFF
OFF
SW4
SW4-1
Multiple outdoor unit control
Inactive
Active
OFF
OFF
SW4-2
Position of multiple outdoor
Slave
Master
OFF
OFF
unit control *
2
SW4-3
-
-
-
OFF
OFF
SW4-4
-
-
-
OFF
OFF
SW4-5
Emergency mode
Normal
Emergency mode
OFF*
3
OFF*
3
(heater only operation)
(activated)
SW4-6
Emergency mode
Normal
Emergency mode
OFF*
3
OFF*
3
(boiler operation)
(activated)
Default
Two
Zone
Default
Single
Zone
ON
OFF
Function
DIP Switch
43
Pre-Plumbed Slimline Cylinder Installation Manual
Summary of Contents for Ecodan PUHZ-HW140VHA-BS