
27
SERVICE FUNCTIONS
10
10-2. P.C. BOARD MODIFICATION FOR INDIVIDUAL OPERATION
A maximum of 4 indoor units with wireless remote controllers can be used in a room.
In this case, to operate each indoor unit individually by each remote controller, P.C. boards of remote controller must
be modified according to the number of the indoor unit.
10-1. TIMER SHORT MODE
For service, set time can be shortened by short circuit of JPG and JPS the electronic control P.C. board.
The time will be shortened as follows. (Refer to page 36.)
Set time : 1 minute
➔
1-second
Set time : 3 minute
➔
3-second (It takes 3 minutes for the compressor to start operation. However, the starting time is
shortened by short circuit of JPG and JPS.)
How to modify the remote controller P.C. board
Remove batteries before modification.
The board has a print as shown below :
NOTE :
At power supply failure or installation, indoor unit deletes the memory about remote controller. When the power supply
is turned on and indoor unit receives the first signals from the remote controller, the remote controller number is desig-
nated as the indoor unit number. Therefore at and after the second time indoor unit accepts the remote controller of the
initial setting number.
At setting-error, turn the power supply off to cancel the individual operation and then turn the power supply on to restart
the setting.
MS-C18TV -
MS-C24TV -
E1
E1
The P.C. board has the print “J1” and “J2”. Solder “J1” and “J2” according to the number of indoor unit as shown in Table 1.
After modification, push the RESET button.
NOTE : For remodelling, take out the bat-
teries and push the
OPERATE/STOP(ON/OFF) button
twice or 3 times at first.
After finish remodelling, put back
the batteries then push the RESET
button.
Table 1
No. 1 unit
No. 2 unit
No. 3 unit
No. 4 unit
1 unit operation
No modification
–
–
–
2 units operation
Same as at left
Solder J1
–
–
3 units operation
Same as at left
Same as at left
Solder J2
–
4 units operation
Same as at left
Same as at left
Same as at left
Solder both J1 and J2
OB273--1.qxp 12/25/00 1:42 PM Page 27