12
REFRIGERANT SYSTEM DIAGRAM
7
MS-C18TV -
E1
MU-C18TV -
E1
INDOOR UNIT
OUTDOOR UNIT
Indoor
heat
exchanger
Room temperature
thermistor
RT11
Refrigerant pipe
[
15.88
(Option)
(with heat insulator)
Flared
connection
Indoor coil
thermistor
RT12
Refrigerant pipe
[
6.35
(Option)
(with heat insulator)
Stop valve
Capillary tube
[
3.0 X
[
2.0 X 850
Compressor
Stop valve
(with service port)
Outdoor
heat
exchanger
Refrigerant flow in cooling
Strainer
Unit:mm
Distributor
Unit:mm
MS-C24TV -
E1
MU-C24TV -
E1
INDOOR UNIT
OUTDOOR UNIT
Indoor
heat
exchanger
Room temperature
thermistor
RT11
Refrigerant pipe
[
15.88 (Option)
(with heat insulator)
Flared
connection
Indoor coil
thermistor
RT12
Refrigerant pipe
[
9.52
(Option)
(with heat insulator)
Stop valve
Capillary tube
[
3.0 X
[
2.0 X 550
Compressor
Stop valve
(with service port)
Outdoor
heat
exchanger
Refrigerant flow in cooling
Strainer
Distributor
OB273--1.qxp 12/25/00 1:41 PM Page 12