Foreword

Mitsubishi Electric, MA00854

Installation manual for the E1000 series operator panels

Foreword

The E1000 operator panel is developed to satisfy the demands of 
human-machine communication. Built-in functions such as displaying and control-
ling text, dynamic indication, time channels, alarm and recipe handling are included.

The operator panel work, for the most part, in an object-oriented way, making it easy 
to understand and use. The configuration operation of the panel is made in a person-
al computer, using the configuration tool E-Designer. The project is then transferred 
and stored in the operator panel.

The operator panel can be connected to many types of automation equipment, such 
as PLCs, servos or drives. In this manual the expression “the controller“ is used as a 
general term for the connected equipment.

This manual explains how to install the operator panel. Please refer to the reference 
manual for further information.

© 

 Mitsubishi Electric, MA00854, 2007-09

The information in this document is subject to change without notice and is provided as available at the time 
of printing. The manufacturer reserves the right to change any information without updating this publication. 
The manufacturer assumes no responsibility for any errors that may appear in this document.
Read the entire installation manual prior to installing and using this equipment.
Only qualified personnel may install, operate or repair this equipment. The manufacturer is not responsible 
for modified, altered or renovated equipment.
Because the equipment has a wide range of applications, users must acquire the appropriate knowledge to use 
the equipment properly in their specific applications.
Persons responsible for the application and the equipment must themselves ensure that each application is in 
compliance with all relevant requirements, standards and legislation in respect to configuration and safety.
Only parts and accessories manufactured according to specifications set by The manufacturer may be used.
THE MANUFACTURER SHALL NOT BE LIABLE TO ANYONE FOR ANY DIRECT, INDIRECT, 
SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE 
INSTALLATION, USE OR REPAIR OF THIS EQUIPMENT, WHETHER ARISING IN TORT, 
CONTRACT, OR OTHERWISE. BUYER'S SOLE REMEDY SHALL BE THE REPAIR, 
REPLACEMENT, OR REFUND OF PURCHASE PRICE, AND THE CHOICE OF THE APPLICABLE 
REMEDY SHALL BE AT THE SOLE DISCRETION OF THE MANUFACTURER.

Summary of Contents for E1000 series

Page 1: ...MITSUBISHI ELECTRIC E1022 Installation manual MA00854 2007 09 English ...

Page 2: ... manufacturer reserves the right to change any information without updating this publication The manufacturer assumes no responsibility for any errors that may appear in this document Read the entire installation manual prior to installing and using this equipment Only qualified personnel may install operate or repair this equipment The manufacturer is not responsible for modified altered or renov...

Page 3: ... Scrapping 6 2 Installation 7 2 1 Space Requirements 7 2 2 Installation Process 7 2 2 1 Mode Switches 9 2 2 2 Connections to the Controller 9 2 2 3 Other Connections and Peripherals 9 3 Technical Data 11 4 Chemical Resistance 13 4 1 Metal Casing 13 4 2 Keyboard and Display 13 4 2 1 Autotex F157 13 4 2 2 Display Surface 14 5 Operator Panel Drawings 17 5 1 Communication Ports 17 5 2 E1022 Outline 18...

Page 4: ...Table of Contents Mitsubishi Electric MA00854 ...

Page 5: ...ly UL approved expansion units are allowed to be connected to the port designated EXPANSION WARNING EXPLOSION HAZARD Do not replace expansion unit unless power has been switched off or the area is known to be non hazardous This product contains battery this must only be changed in an area known to be non hazardous Permitted types are shown in the section Technical Data 1 2 General Read the safety ...

Page 6: ...ed personnel may install the operator terminal Separate the high voltage signal and supply cables Make sure that the voltage and polarity of the power source is correct before connecting the product to the power outlet Peripheral equipment must be appropriate for the application and location 1 4 During Use Keep the operator terminal clean Emergency stop and other safety functions may not be contro...

Page 7: ...y If damage is found notify the supplier Note Place the operator panel on a stable surface during installation Dropping it or letting it fall may cause damage 2 Place the panel cut out where the operator panel is to be situated draw along the outer sides of the holes and cut according to the markings 100 mm 4 0 inch 50 mm 2 0 inch 155 mm 50 mm 2 0 inch 6 10 inch 100 mm 4 0 inch 155 mm 6 10 inch 44...

Page 8: ...panel x 6 0 5 1 0 Nm B C D A Caution Ensure that the operator panel and the controller system have the same electrical grounding reference voltage level otherwise errors in communication may occur Caution Use only shielded communication cables Separate high voltage cables from signal and supply cables Caution The operator panel must be brought to ambient temperature before it is started up If cond...

Page 9: ... Connections to the Controller For information about the cables to be used when connecting the operator panel to the controller please refer to the help file for the driver in question 2 2 3 Other Connections and Peripherals Cables peripheral equipment and accessories must be suitable for the application and its environment For further details or recommendations please refer to the supplier 1 2 3 ...

Page 10: ...Installation 10 Mitsubishi Electric MA00854 ...

Page 11: ...D Power consumption at rated voltage Normal 0 1 A Maximum 0 3 A Display FFSTN LCD 240 x 64 pixels monocrome transmissive negative LED backlight lifetime at the ambient temperature of 25 C 50 000 h Active area of display W x H 90 2 x 24 0 mm Fuse Internal DC fuse 1 0 AT 5x20 mm Power supply 24V DC 20 30V DC 3 pin jack connection block CE The power supply must conform with the requirements for SELV ...

Page 12: ...Technical Data 12 Mitsubishi Electric MA00854 ...

Page 13: ... acid 10 Urea saturated FAM Normal petrol Sodium di chromate saturated Hydroperoxide 3 Alcohol 95 Caustic soda 5 Acetic acid 10 Phosphoric acid 43 Sodium hypochlorite solution Alu cleaner Glycol Sodium carbonate 10 Industrial petrol Sodium chloride 20 Potassium ferrocyanide ferricyanide Sodium hypchlorite 20 bleach 1 1 1 Trichloroethane Genklene Cyclohexanol Acetaldehyde Ethylacetate Diacetone alc...

Page 14: ...le change Ammonia 40 Linseed oil Dioctyl Phthalate Caustic soda 40 Paraffin oil Sodium carbonate Hydrogen peroxide 25 Blown castor oil Petrol Alkalicarbonate Silicone oil Teepol Bichromate Turpentine substitute Water Diesel oil Univeral brake fluid Sea water Acetonitrile Decon Sodium bisulphate Aviation fuel Concentrated mineral acids Benzyl alcohol Concentrated caustic solution Mehylene chloride ...

Page 15: ... Electric MA00854 15 Carbon tetrachloride Hydrogen peroxide 28 Sodium hypochlorite 10 Caustic soda 48 Isopropyl alcohol Sulfuric acid specific gravity 1 84 Citric acid Kerosene Sulfuric acid 30 Cotton seed oil Methy alcohol Toluene ...

Page 16: ...Chemical Resistance 16 Mitsubishi Electric MA00854 ...

Page 17: ...Operator Panel Drawings Mitsubishi Electric MA00854 17 5 Operator Panel Drawings 5 1 Communication Ports Drawing No S 05005 RS 232 RS 422 RS 422 485 RS 485 ...

Page 18: ...Operator Panel Drawings 18 Mitsubishi Electric MA00854 5 2 E1022 Outline Drawing No S 06840 unit mm ...

Page 19: ...Operator Panel Drawings Mitsubishi Electric MA00854 19 5 3 E1022 Text Strip Drawing No S 06816 9 0 unit mm R1 4x Text max 15 5x7 5 Text max 18 5x7 5 4 5 11 25 19 0 138 0 20 5 20 5 20 5 19 0 ...

Page 20: ...Mitsubishi Electric Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 USA Mitsubishi Electric Europe B V Gothaer Strasse 8 D 40880 Ratingen Germany MITSUBISHI ELECTRIC ...

Reviews: