'11 • SRK-T-118
'09•SRK-DB-087D
(a)
Inspection of electronic expansion valve
(OHFWURQLFH[SDQVLRQYDOYHRSHUDWHVIRUDSSUR[VHFRQGVDIWHUWKHSRZHURQLQRUGHUWRGHWHUPLQHLWVDSHUWXUH&KHFNWKH
RSHUDWLQJVRXQGDQGYROWDJHGXULQJWKHSHULRGRIWLPH9ROWDJHFDQQRWEHFKHFNHGGXULQJRSHUDWLRQLQZKLFKRQO\WKHDSHUWXUH
FKDQJHRFFXUV
,ILWLVKHDUGWKHVRXQGRIRSHUDWLQJHOHFWURQLFH[SDQVLRQYDOYHLWLVDOPRVWQRUPDO
,IWKHRSHUDWLQJVRXQGLVQRWKHDUGFKHFNWKHRXWSXWYROWDJH
6
White
Ye
llow
Orange
Blue
Red
5 4 3 2 1
([SDQVLRQYDOYHFRQQHFWRU
3EODFN
$SSUR[9LVGHWHFWHGIRUVHFRQGVDIWHUWKHSRZHURQ
,IYROWDJHLVGHWHFWHGWKHRXWGRRU3&%LVQRUPDO
,IWKHH[SDQVLRQYDOYHGRHVQRWRSHUDWHQRRSHUDWLQJVRXQGZKLOHYROWDJHLVGHWHFWHGWKHH[SDQVLRQYDOYHLVGHIHFWLYH
• Inspection of electronic expansion valve as a separate unit
0HDVXUHWKHUHVLVWDQFHEHWZHHQWHUPLQDOVZLWKDQDQDORJWHVWHU
Measuring point
Resistance when normal
±
DW&
±
±
±
(b)
Outdoor unit fan motor check procedure
:KHQWKHRXWGRRUXQLWIDQPRWRUHUURULVGHWHFWHGGLDJQRVHZKLFKRIWKHRXWGRRUXQLWIDQPRWRURURXWGRRU3&%LVGHIHFWLYH
'LDJQRVHWKLVRQO\DIWHUFRQ¿UPLQJWKDWWKHLQGRRUXQLWLVQRUPDO
2XWGRRU3&%RXWSXWFKHFN
7XUQRIIWKHSRZHU
'LVFRQQHFWWKHRXWGRRUXQLWIDQPRWRUFRQQHFWRU&1)$1
:KHQWKHLQGRRUXQLWLVRSHUDWHGE\LQVHUWLQJWKHSRZHUVXSSO\SOXJDQGSUHVVLQJ21WKHEDFNXSVZLWFKIRUPRUHWKDQ
VHFRQGVLIWKHYROWDJHRISLQ1R
②
LQWKHIROORZLQJ¿JXUHLVRXWSXWIRUVHFRQGVDWVHFRQGVDIWHUWXUQLQJ³21´WKH
EDFNXSVZLWFKWKHRXWGRRU3&%LVQRUPDOEXWWKHIDQPRWRULVGHIHFWLYH
,IWKHYROWDJHLVQRWGHWHFWHGWKHRXWGRRU3&%LVGHIHFWLYHEXWWKHIDQPRWRULVQRUPDO
1RWH7KHYROWDJHLVRXWSXWWLPHVUHSHDWHGO\,ILWLVQRWGHWHFWHGWKHLQGRRUXQLWGLVSOD\VWKHHUURUPHVVDJH
2) Fan motor resistance check
1RWHV5HPRYHWKHIDQPRWRUDQGPHDVXUHLWZLWKRXWSRZHUFRQQHFWHGWRLW
1RWHV
,IWKHPHDVXUHGYDOXHLVEHORZWKHYDOXHZKHQWKHPRWRULVQRUPDOLWPHDQV
WKDWWKHIDQPRWRULVIDXOW\
Measuring point
Resistance when normal
⑥ − ④
5HG
−
%ODFN
0RUKLJKHU
③ − ④
:KLWH
−
%ODFN
0RUKLJKHU
Measuring
point
Resistance when
normal
⑥ − ④
'&a9
③ − ④
'&9
② − ④
'&VHYHUDO9a9
① − ④
'&VHYHUDO9a9
DC15V
DC several (4~7V)
Outdoor PCB
GND
(−)
DC308~336V
CNFAN
Red
Black
White
Yellow
Blue
①
②
③
④
⑤
⑥
①
②
③
④
⑤
⑥
FM
0
Summary of Contents for DXK09ZJ-S
Page 2: ......
Page 3: ...TECHNICAL MANUAL ...
Page 12: ... 11 SRK T 118 3 Remote controller a Wireless remote controller Unit mm 60 17 3 150 ...
Page 66: ... 63 11 SRK T 118 09 SRK DB 087D Service data record form 57 ...
Page 74: ... 71 11 SRK T 118 09 SRK DB 087D 11 Outdoor unit inspection points DXC09ZJ S 12ZJ S 73 73 64 ...
Page 87: ... 84 11 SRK T 118 11 3 Super link E board SC ADNA E F SL2NA E and SL3N AE BE to control ...
Page 88: ... 85 11 SRK T 118 ...
Page 89: ... 86 11 SRK T 118 ...
Page 103: ... 100 CRBE0323 6 13 11 18 12 15 16 3 17 14 2 4 9 8 7 5 1 8 19 8 10 PANEL FAN ASSY ...
Page 107: ... 104 CRBE0323 6 13 11 18 12 15 16 3 17 14 2 4 9 8 7 5 1 8 19 8 10 PANEL FAN ASSY ...
Page 111: ... 108 CRBE0324 9 13 15 16 14 17 7 6 4 19 1 8 3 11 5 18 10 10 10 2 12 PANEL FAN ASSY ...