– 19 –
4.3.6
Extension to operate the IP alarm notification function correctly in an NAPT configuration
When recorders are networked in an NAPT configuration, it is necessary to extend the setting of the registered
recorders data in order to receive IP alarm notification from the recorders and then access those recorders (
see section 5 on page 40).
To extend the setting, put a checkmark in the box next to [Use more than one port forward] on the Recorder Regist
(or Recorder Edit) dialog box. Then, the Recorder Regist (or Recorder Edit) dialog box is extended and the
following setting item is additionally displayed.
When you enter the local IP address of the recorder networked in an NAPT configuration in the [Local IP Address]
box, it becomes possible to access the recorder that issued an IP alarm notification only by clicking the [Connect]
button of the pop-up message that is displayed at the time of receipt of the IP alarm notification.
4.4
Accessing for communication/canceling communication
4.4.1
Accessing a recorder for communication
To access a recorder, select the recorder from the recorder list on the main window and click the [Connect]
checkbox (
see 3.3 on page 9).
The recorder login dialog box appears. Enter the user ID and password that have been registered in the recorder
and click [OK]. By default, “root” and “admin000” are displayed as the user ID and password on the recorder login
dialog box.
Following two default users have been registered in the recorder.
User ID
Password
Authority
root
admin000
This user has authority to control almost all the communication functions of the
recorder.
guest
guest
This user has authority only to view live images.
For addition, change, deletion, and authority of registered users,
see 4.13 on page 30.
When this software accesses the recorder successfully, the camera windows of all the registered cameras are
displayed and those windows start refreshing their live images. The recorder status indicators on the main window
(
see 3.3 on page 9) illuminate according to the recorder’s operation status.
4.4.2
Canceling communication with a recorder
To cancel communication with a recorder, select the recorder you want to disconnect from the recorder list on the
main window and click the [Connect] checkbox (
see 3.3 on page 9). The following confirmation dialog box
appears. Click [Yes] to cancel the communication with the recorder.
[Connect] checkbox
Name of the recorder
to be disconnected