Mitsubishi Electric City Multi PMFY-P100VBM-E Installation Manual Download Page 9

9

6. Test run (Fig. 6-1)

TIMER SET

PAR-20MAA

ON/OFF 

CENTRALLY CONTROLLED

ERROR CODE

CLOCK

ON

OFF

˚C

CHECK

CHECK MODE

FILTER

TEST RUN

FUNCTION

˚C

1Hr.

NOT AVAILABLE

STAND BY 
DEFROST

FILTER

CHECK TEST

TEMP.

2

BC

3

4

5

1

A

E

D

1

Press [TEST RUN] button twice 

 displaying [TEST RUN] on the screen.

2

Press [Selecting operation] button. 

 Check that wind is blowing out.

3

Press [Fan speed adjustment] button. 

 Check that the wind speed is changed.

4

Press [Up/down airflow selection] button to change wind direction.

5

Press [ON/OFF] button to clear test run

. →

 Test run stops.

A

Lighting in operation

B

Displaying inspection code

C

Displaying remaining test run time

D

Displaying indoor unit’s liquid pipe temperature

E

Displaying test run

Note:
• The 2-hour-set timer is activated to automatically stop test run after two hours.
• The remote controller displays the temperature of the indoor unit’s liquid

pipe on the temperature display section during test run.

Fig. 6-1

Summary of Contents for City Multi PMFY-P100VBM-E

Page 1: ... ÛË Ú Î ÏÂ ÛÙÂ È ÛÂÙÂ ÚÔÛÂ ÙÈÎ Ùfi ÙÔ ÂÁ ÂÈÚ ÈÔ ÂÁÎ Ù ÛÙ ÛË ÚÈÓ Ú ÛÂÙÂ ÙËÓ ÂÁÎ Ù ÛÙ ÛË ÙË ÌÔÓ ÎÏÈÌ ÙÈÛÌÔ MANUAL DE INSTALAÇÃO Para segurança e utilização correctas leia atentamente este manual de instalação antes de instalar a unidade de ar condicionado MONTAJ ELK TABI Emniyetli ve do ru biçimde nas l kullan laca n ö renmek için lütfen klima cihaz n monte etmeden önce bu elkitab n dikkatle okuyunuz...

Page 2: ...s etc 1 Safety precautions 2 2 Installing the indoor unit 2 3 Refrigerant pipe and drain pipe 4 4 Electrical work 6 5 Installing the grille 7 6 Test run Fig 6 1 9 1 Safety precautions Indicates an action that must be avoided Indicates that important instructions must be followed Indicates a part which must be grounded Indicates that caution should be taken with rotating parts Indicates that the ma...

Page 3: ... been fixed and the direction of the pipes has been determined place the refrigerant and drainage pipes the wiring for the remote controller and the wiring that connects the indoor and outdoor units in their desired locations before suspending the indoor unit This is especially important in cases where the ceiling is already in existence 1 Wooden structures Fig 2 4 Use tie beams single storied hou...

Page 4: ...ter in it Fig 2 8 Make sure that any slant in the unit after installation is less than 0 5 degrees approx 6 mm on the long dimension of the unit 5 Tighten all the nuts Fig 2 9 A Suspension bolt 3 8 or M10 B Clear plastic tubing C Underside of bracket D Secure front panel here E Make these surfaces are flush with each other 0 3 mm 2 5 Fresh air intake hole Fig 2 10 At the time of installation use t...

Page 5: ...Fig 3 4 Use O D ø26 mm PVC TUBE for drain piping and provide 1 100 or more down ward slope Be sure to connect the piping joints using adhesive of polyvinyl chloride family Observe the figure for piping work Use attached drain hose to change the pipe extraction direction 1 Correct piping 2 Wrong piping A Insulation 9 mm or more B Downward slope 1 100 or more C Support metal K Air bleeder L Raised M...

Page 6: ...er Connect the remote controller s transmission cable within 10 m using a 0 75 mm2 core cable If the distance is more than 10 m use a 1 25 mm2 junction cable 1 MA Remote controller Connect the 1 and 2 on indoor unit TB15 to a MA remote controller Non polar ized 2 wire DC 9 to 13 V between 1 and 2 MA remote controller 2 M NET Remote controller Connect the M1 and M2 on indoor unit TB5 to a M NET rem...

Page 7: ...mm2 2 M NET Remote control cables Kind of remote control cable Shielding wire MVVS Cable diameter More than 0 5 to 1 25 mm2 Remarks When 10 m is exceeded use cable with the same specifications as transmission line wiring 3 MA Remote control cables Kind of remote control cable 2 core cable unshielded Cable diameter 0 3 to 1 25 mm2 Fig 4 3 SW14 0 SW11 0 SW12 0 1 2 3 4 5 6 7 8 9 10 ON OFF SW1 SW5 220...

Page 8: ...ng bolts 2 and securing screws 3 in the center three places Finally tighten the securing bolts 2 in the four places at left and right At this point make sure there are no gaps between the indoor unit and the front panel and between the front panel and the ceiling surface If there are gaps the wind may come in and it may cause water to drip Fig 5 6 Tighten the securing bolts 2 and securing screws 3...

Page 9: ... adjustment button Check that the wind speed is changed 4 Press Up down airflow selection button to change wind direction 5 Press ON OFF button to clear test run Test run stops A Lighting in operation B Displaying inspection code C Displaying remaining test run time D Displaying indoor unit s liquid pipe temperature E Displaying test run Note The 2 hour set timer is activated to automatically stop...

Page 10: ... EEC Electromagnetic Compatibility Directive 89 336 EEC This product is designed and intended for use in the residential commercial and light industrial environment HEAD OFFICE MITSUBISHI DENKI BLDG 2 2 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN Printed in Japan BG79U328H02 The product at hand is based on the following EU regulations ...

Reviews: