Note
1.
At servicing for outdoor unit, always follow the wiring diagram
of outdoor unit.
2. In case of using MA-Remote controller
, please connect to
TB15. (Remote controller wire is non-polar
.)
3. In case of using M-NET
, please connect to
TB5.
(T
ransmission line is non-polar
.)
4. Symbol [S] of
TB5 is the shield wire connection.
5. Symbols used in wiring diagram above are, : terminal
block, :connector
.
6.
The setting of the SW2, SW3 dip switches dif
fers in the capacity
.
For the detail, refer to fig.
1.
7. Please set the switch SW5 according to the power supply
voltage.
CN51
CN52
SW2
SW3
SW4
SWE
A.B
Address board
SW1
SW5
SW1
1
SW12
Mode selection
V
oltage selection
Address setting 1s digit
Address setting 10ths digit
SW14
Branch No.
Centrally control
Remote Indication
Switch
Switch
Capacity code
Mode selection
Model selection
DRAIN UP
MACHINE(TEST
MODE)
ZNR
V
aristor
X1
Aux.relay
Drain pump
FUSE
Fuse
(T6.3AL
250V
)
LED1
Power supply
(I.B
)
LED2
Power supply
(I.B
)
TH21
MF
MV
Thermistor
Room temp. detection
(32°F/15k
Ω
, 77°F/5.4k
Ω
)
Pipe temp. detection / Liquid
(32°F/15k
Ω
, 77°F/5.4k
Ω
)
Pipe temp. detection / Gas
(32°F/15k
Ω
, 77°F/5.4k
Ω
)
LEV
Linear expansion valve
TH22
TH23
Fan motor
Vane motor
TB15
MA-Remote Controller
[Legend]
Symbol
Name
I.B
Indoor controller board
CN25
CN27
CN32
Connector
Humidifier
Damper
Remote switch
Symbol
Name
DS
DP
Drain sensor
Drain pump
TB2
TB5
Transmission
Terminal
block
Power supply
Models
P06
P08
P12
P15
SW2
123456
ON OFF
123456
ON OFF
123456
ON OFF
123456
ON OFF
SW3
123456
7
ON OFF
123456
7
ON OFF
123456
ON OFF
123456
7
7
8
8
8
8
9
9
9
9
10
10
10
10
ON OFF
<fig.
1>
Mark
Meaning
Function
Power supply for MA-Remote controller
Main power supply (Indoor unit:208-230V) Power on
→
Iamp is lit
LED on indoor board for service
LED1
Main power supply
Power supply for MA-Remote controller on
→
Iamp is lit
LED2
<
2> Use Copper Supply Wire.
SWE
ON OFF
GR
CN2M (
BLU
)
M-NET
CN3A (BLU
)
REMOCON
TB5
(SHIELD)
M1
M2
TB2
TB15
1
S
TH23
TH22
CN20 (
RED
)
INTAKE
CN60 (WHT
)
LEV
CN52 (GRN
)
REMOTE
INDICATION
CN6V1
(GRN
)
VANE
TH21
CNMF2
(WHT
)
CNMF1
(WHT
)
CN31 (WHT
)
DRAIN
CN44 (WHT
)
LIQUID/GAS
CN25 (WHT
)
CN27 (
RED
)
ADDRESS
CN81
(RED
)
CN42 (RED
)
ADDRESS
CN32
(WHT
)
REMOTE SWITCH
X1
CNP (YLW
)
D.U.M
CND
(BLK
)
FUSE
DSA
ZNR01
DC311 ~339V
ZNR02
U
CN51
(WHT
)
CENTRALLY CONTROL
CN41 (WHT
)
HA
4
8
5
5
LEV
M
DS
DP
t°
t°
t°
t°
2
L1
L2
123456789
1
0
SW3
123456
SW2
12345
SW4
8
1
5
1
5
13
6
1
6
1
5
1
4
1
2
1
2
1
2
1
4
1
1
3
3
1
3
1
3
1
2
1
2
1
1
4
1
3
5
7
86
4
2
I.B
M 1~
M
U
MS 3~
PULL BOX
FUSE (15A
)
BREAKER
(15A
)
POWER SUPPLY ~ / N 208-230V 60Hz
TO NEXT INDOOR UNIT
BLU
BRN
ORN
YLW
RED
WHT
SW14
SWC
BRANCH
No.
SW11
1s
DIGIT
SW12
10ths
DIGIT
123456789
1
0
SW1
SW5
230V
208V
(RED)
ADDRESS
CN82
(RED)
ADDRESS
CN43
A.B
8
1
4
1
0
1
23
45
67
8
9
A
BC
D
EF
0
1
2 3 4
5
6
7
89
0
1
2 3 4
5
6
78
9
TO MA-
REMOTE
CONTROLLER DC8.7-13V
TO OUTDOOR UNIT BC CONTROLLER REMOTE CONTROLLER DC24-30V
RED
BLU
GRN/YLW
MF
MV
ORN
*See fig.
1
ORN
BLU
BLU
BLU
BLU
LED2
LED1
GRN
YLW
ORN
RED
BRN
BLK
PMFY-P06NBMU-E#2 PMFY-P08NBMU-E#2 PMFY-P12NBMU-E#2 PMFY-P15NBMU-E#2
PMFY-P06NBMU-ER3 PMFY-P08NBMU-ER3 PMFY-P12NBMU-ER3 PMFY-P15NBMU-ER3
PMFY-P06NBMU-ER4 PMFY-P08NBMU-ER4 PMFY-P12NBMU-ER4 PMFY-P15NBMU-ER4
OC341F
Summary of Contents for CITY MULTI PMFY-P06NBMU-E
Page 41: ...41 OC341F ...