2

1

[Set Temperature] Button

2

[TIMER MENU] Button

3

[Mode] Button

[MONITOR/SET] Button

[BACK] Button

4

[TIMER ON/OFF] Button

5

[Louver] Button

[SET DAY] Button

[OPERATION] Button

6

[Fan Speed] Button

7

[Vane Control] Button

8

[Ventilation] Button

[OPERATION] Button

9

[CHECK/CLEAR] Button

0

[TEST RUN] Button

A

[FILTER] Button

B

[ON/OFF] Button

[ ] Button

C

Position of built-in room temperature sensor

D

[Set Time] Button

Never expose the remote controller to direct sunlight. Doing so can result in
the erroneous measurement of room temperature.

Never place any obstacle around the lower right-hand section of the remote
controller. Doing so can result in the erroneous measurement of room tem-
perature.

ON/OFF 

FILTER

CHECK

CLEAR

MENU

ON/OFF

TEST

TEMP.

CLOCK

OPERATION

BACK

DAY

MONITOR/SET

1

2

3

4

D

5 6 8

9

C

0

A

B
7

Remote controller-Button

Touche Commande à distance

GB

F

1

Touche [Réglage de la température]

2

Touche [TIMER MENU]

3

Touche [Mode]

Touche [MONITOR/SET]

Touche [BACK]

4

Touche [TIMER ON/OFF]

5

Touche [Louvre]

Touche [SET DAY]

Touche [OPERATION]

6

Touche [Vitesse du ventilateur]

7

Touche [Commande des ailettes]

8

Touche [Ventilation]

Touche [OPERATION]

9

Touche [CHECK/CLEAR]

0

Touche [TEST RUN]

A

Touche [FILTER]

B

Touche [ON/OFF]

Touche [ ]

C

Position du capteur de température de la pièce intégré

D

Touche de [réglage de l’heure]

Ne jamais laisser la commande à distance en plein soleil sinon les données de
température ambiante risquent d’être erronées.

Ne jamais placer d’obstacle devant la partie inférieure droite de la commande
à distance sinon la lecture des températures ne sera pas correcte.

KB79P490H01_p02_gb_e.p65

6/18/09, 7:20 PM

2

Summary of Contents for CITY MULTI PEFY-P06NMAU-E

Page 1: ...ERATION MANUAL For safe and correct use please read this operation manual thoroughly before operating the air conditioner unit MANUEL D UTILISATION Pour une utilisation correcte sans risques veuillez lire le manuel d utilisation en entier avant de vous servir du climatiseur F GB ...

Page 2: ...F FILTER CHECK CLEAR MENU ON OFF TEST TEMP CLOCK OPERATION BACK DAY MONITOR SET 1 2 3 4 D 5 6 8 9 C 0 A B 7 Remote controller Button Touche Commande à distance GB F 1 Touche Réglage de la température 2 Touche TIMER MENU 3 Touche Mode Touche MONITOR SET Touche BACK 4 Touche TIMER ON OFF 5 Touche Louvre Touche SET DAY Touche OPERATION 6 Touche Vitesse du ventilateur 7 Touche Commande des ailettes 8 ...

Page 3: ...pièce N Réglage des ailettes O Vitesse du ventilateur P Témoin de fonctionnement Remote controller Display Affichage Commande à distance GB F A Current time Timer time B Centralized control indicator C Timer OFF indicator D Timer mode indicator E Operation mode display COOL DRY AUTO FAN HEAT F Function mode indicator G Preset temperature H Power indicator I Louver J Ventilation K Filter sign L Sen...

Page 4: ...4 4 2 In case of bottom inlet En cas d entrée sur le dessous 1 In case of rear inlet En cas d entrée arrière A Filter Filtre Air Flow Flux d air A 1 A 2 Fig A ...

Page 5: ...it should be installed in a location where air and noise emit ted by the unit will not disturb the neighbours 2 Indoor unit Warning The indoor unit should be securely installed If the unit is loosely mounted it may fall causing injury 3 Remote controller Warning The remote controller should be installed in such a way that children cannot play with it 4 Drain hose Caution Make sure that the drain h...

Page 6: ...refrigerant into the atmosphere also damages the environment 2 Names and functions of various parts Attachment and detachment of filter Fig A P 4 3 How to operate Before starting operation Start running after the PLEASE WAIT display has disappeared The PLEASE WAIT display briefly appears on the room temperature display max 3 min utes when the power is turned on and after a power failure This does ...

Page 7: ...ture and automatically repeat ON OFF 2 When reaching room temperature of your choice Both the compressor and indoor fan stop When stop continues for 10 minutes the compressor and indoor fan are oper ated for 3 minutes to keep the humidity low For heating Press the 3 Mode BACK Button to bring up the HEAT display Regarding displays during heating operation DEFROST Displayed only during the defrostin...

Page 8: ...ower failure The power supply is turned OFF The fuse in the power supply is gone The earth leakage breaker is gone Improper temperature adjustment The filter is filled with dust and dirt There are some obstacles at the air inlet and outlet of the indoor and outdoor units Windows and doors are open The restart preventing circuit is in operation for 3 min utes Indoor unit operation was restarted dur...

Page 9: ... of the professional engineering work required for transferring the installa tion Caution When moving or reinstalling the air conditioner consult with your dealer Defective installation can result in electric shock fire etc Regarding noise In installing work choose a place that can fully bear the weight of the air con ditioner and where noise and vibration can be reduced Choose a place where cool ...

Page 10: ... 9 13 16 732 28 13 16 0 14 0 20 0 28 0 40 0 60 35 50 70 100 150 42 93 Standard filter Notes 1 Cooling Heating capacity indicates the maximum value at operation under the following condition Cooling Indoor 80 F 26 7 C D B 67 F 19 4 C W B Outdoor 95 F 35 C D B Heating Indoor 70 F 21 1 C D B Outdoor 47 F 8 3 C D B 43 F 6 1 C W B Pipe length 7 5 m 24 9 16 ft Height difference 0 m 0 ft 2 The external s...

Page 11: ... de cet appareil à des enfants en bas âge ou à des handicapés sans supervision Toujours prendre toutes les précautions nécessaires pour éviter que des enfants en bas âge jouent avec cet appareil N utilisez pas d additif de détection des fuites 1 Appareil extérieur Avertissement L appareil extérieur doit être installé sur une surface plane et stable dans un endroit non sujet à l accumulation de nei...

Page 12: ...t arrêter le fonctionnement du climatiseur aé rer convenablement la pièce et prendre contact avec le revendeur S il n est pas remédié à la situation des accidents risquent de se produire suite à un manque d oxygène Lorsque le climatiseur ne doit pas être utilisé pendant une certaine période Si le climatiseur ne doit pas être utilisé pendant une certaine période à cause d un changement de climat et...

Page 13: ...ans les cas suivants L air ne souffle pas lorsque le chauffage démarre Pour éviter le souffle d air froid le ventilateur interne est progressivement allumé par étapes entre un très léger souffle un léger souffle la soufflerie programmée en fonction de l augmentation de la température de l air pro pulsé Il faut attendre un moment avant que le ventilateur ne tourne comme indiqué Le ventilateur ne to...

Page 14: ...utilisation d appareils au gaz pendant le fonctionnement du climatiseur Si vous utilisez l appareil de ventilation LOSSNAY conçu par notre société vous pouvez aérer la pièce en perdant moins d énergie Pour plus de détails sur cet appareil veuillez contac ter votre revendeur 5 Entretien de l appareil Toujours demander à la personne responsable de la maintenance d effec tuer l entretien du filtre Av...

Page 15: ... pareil est en cours de fonctionnement Le code et la mention de vérification CONTROLE clignotent sur l affichage à cristaux liquides Tous les témoins sont éteints sauf le témoin de mise sous tension Tous les témoins sont éteints sauf le témoin de mise sous tension L affichage à cristaux li quides indique que l ap pareil est en cours de fonctionnement 6 Guide de dépannage Avant de faire appel au se...

Page 16: ...e habitation veuillez prendre contact au préalable avec le revendeur pour une estimation du coût des travaux requis pour le déménage ment de l installation Précaution Lors du déménagement et de la réinstallation du climatiseur veuillez pren dre contact avec votre revendeur car une installation défectueuse peut être la cause d électrocution d incendie etc Faire également attention au bruit Lors des...

Page 17: ...e d usine 3 Le bruit entendu durant le fonctionnement est dû aux informations obtenues dans une chambre sourde Elément Modèle Alimentation Btu h Capacité de refroidissement 1 Capacité de chauffage 1 kW Hauteur mm in Dimensions Largeur mm in Profondeur mm in Poids net kg lb Débit d air Faible Moyenne Grande CFM Ventilateur in WG Pression statique externe 2 Pa Niveau sonore Faible Moyenne Grande 2 3...

Page 18: ......

Page 19: ......

Page 20: ...HI CHIYODA KU TOKYO 100 8310 JAPAN Please be sure to put the contact address telephone number on this manual before handing it to the customer This product is designed and intended for use in the residential commercial and light industrial environment ...

Reviews: