3.  How to operate

3.1.  Turning ON/OFF

ON

Press the [ON/OFF] button.

The ON/OFF lamp will light up in green, and 

the operation will start.

 

*

The unit will operate with the previously-

set operation mode, set temperature, and 

fan speed.

OFF

Press the [ON/OFF] button again.

The ON/OFF lamp will come off, and the 

operation will stop.

3.2.  Operation mode

F1

F2

F3

F4

Cool

Room

Auto

Set temp.

Mode

Temp.

Fan

Fri

Press the [F1] button to go through the 

operation modes in the order of "Cool, Dry, 

Fan, Auto, and Heat."

 

Select the desired operation mode.

 

* Operation modes that are not available for 

the connected indoor unit will not appear on 

the display.

 

* Depending on the indoor unit model, either 

one or two set temperatures (single or dual 

set point(s)) can be set for Auto mode.

What the blinking mode icon means

The mode icon will blink when other indoor units in the same 

refrigerant system (connected to the same outdoor unit) are already 

operated in a different mode. In this case, the rest of the units in the 

same group can only be operated in the same mode.

Dry mode (Excluding PEFY-P-VMHS-E-F series)

• 

The indoor fan turns to the low-speed operation, disabling the change of fan 

speed.

•  Dry operation cannot be carried out at room temperature of less than 18°C.

•  The dry is a microcomputer-controlled dehumidifying operation which controls 

excessive air-cooling according to the room temperature of your choice. (Not 

usable for heating.)

1. 

Until reaching room temperature of your choice

The compressor and indoor fan function is linked motion according to the 

change of the room temperature and automatically repeat ON/OFF.

2. 

When reaching room temperature of your choice

Both the compressor and indoor fan stop.

When stop continues for 10 minutes, the compressor and indoor fan are 

operated for 3 minutes to keep the humidity low.

Heat mode

“DEFROST” display

Displayed only during the defrosting operation.

“STAND BY” display

Displayed from the start of heating operation until the moment warm air blows out.

 Caution:

• 

Never expose your body directly to cool air for a long time. Excessive 

exposure to cool air is bad for your health, and should therefore be 

avoided.

• 

When the air-conditioner is used together with burners, thoroughly 

ventilate the area. Insufficient ventilation can result in accidents due to 

oxygen deficiency.

• 

Never place a burner at a place where it is exposed to the airflow from the 

air-conditioner. Doing so can result in imperfect combustion of the burner.

• 

The microcomputer functions in the following cases:

 - Air does not blow out when heating starts.

•  To prevent any cool air from escaping, the indoor fan is gradually switched 

in sequence from faint airflow/weak airflow/set airflow according to the 

temperature rise of the blown out air. Wait a moment until the airflow comes 

out naturally.

 - The fan is not moving at the set speed.

•  In some models, the system switches over to faint airflow when the 

temperature of the room reaches the set temperature. In other cases, it 

stops to prevent any cool air from escaping during the defrosting operation.

 - Air flows out even if operation is stopped.

•  Approximately 1 minute after the stop of operation, the indoor fan 

sometimes rotates to eliminate extra heat generated by the electric heater, 

etc. The fan speed comes to low or high.

Auto (dual set point) mode (Excluding PEFY-P-VMHS-E-F 

series)

When the operation mode is set to the Auto (dual set point) mode, two set 

temperatures (one each for cooling and heating) can be set. Depending on the 

room temperature, indoor unit will automatically operate in either the cooling or 

heating mode and keep the room temperature within the preset range.

The set temperatures that are specified for the Cool/Dry mode and the Heat mode 

will be used to automatically control the room temperature to stay within the set 

temperatures. This mode is especially effective during the in-between seasons, 

when the temperature difference between the highest and the lowest is large and 

both heating and cooling modes are used within the same day.

Auto (Single set point) mode (PEFY-P-VMHS-E-F series)

In the single set point mode, the set temperatures for cooling and heating are 

used in common. Cooling operation starts when the outdoor temperature is higher 

than the set temperature, and heating operation starts when the outdoor 

temperature is lower than the set temperature. 

During Auto operation, the unit operation switches to the cooling operation when 

the outdoor temperature keeps higher than the set temperature by 1.5ºC or more 

for consecutive periods of three minutes. 

In the same way, the unit operation switches to the heating operation when the 

outdoor temperature keeps lower than the set temperature by 1.5ºC or more for 

consecutive periods of three minutes. 

Dry

Auto

Fan

Heat

Cool

Room 

temperature

Cool

The room temperature 

changes corresponding 

to the change in the 

outside temperature.

Heat

Cool

Operation pattern during Auto (dual set point) mode

Set temp. 

(Cool)

Heat

Set temp. 

(Heat)

Cooling operation

3 minutes (Switches from heating to cooling) 

Set tempe 1.5ºC 

3 minutes (Switches from cooling to heating) 

Set temperature - 1.5ºC 

Set temperature

Summary of Contents for CITY MULTI PEFY-P-VMA(L)-E Series

Page 1: ...ию кондиционера IŞLETME ELKİTABI Emniyetli ve doğru biçimde nasıl kullanılacağını öğrenmek için lütfen klima cihazını işletmeden önce bu elkitabını dikkatle okuyunuz 操作手冊 運轉本空調機之前 請仔細閱讀本操作手冊 以便安全正確地使用 操作手册 为了确保安全和正确使用 请在使用空调器之前仔细阅读本操作手册 NÁVOD K OBSLUZE Přečtěte si důkladně tento návod k obsluze před použitím klimatizační jednotky Budete ji pak moci využívat bezpečně a správně NÁVOD NA POUŽITIE Skô...

Page 2: ...ς αέρα από κάτω Φίλτρο Ροή αέρα Воздухозаборник сзади Воздухозаборник внизу Фильтр Воздушный поток Arkadaki hava girişi Alttaki hava girişi Filtre Hava akışı 后部进气口 底部进气口 滤网 气流 後側進氣口 底部進氣口 濾網 氣流 Přívod vzduchu v zadní části Přívod vzduchu ve spodní části Filtr Průtok vzduchu Prívod vzduchu na zadnej strane Prívod vzduchu na spodnej strane Filter Prúdenie vzduchu Légbeömlő nyílás a hátoldalon Légbeö...

Page 3: ...een Refer to the button function guide that appears at the bottom of the LCD for the functions they serve on a given screen When the system is centrally controlled the button function guide that corresponds to the locked button will not appear Main display Main menu Fri Room Set temp Mode Temp Fan Cool Auto Main Main display Cursor Page Main menu Vane Louver Vent Lossnay High power Timer Weekly ti...

Page 4: ... controlled Appears when the filter reset function is centrally controlled Indicates when filter needs maintenance Room temperature Current room temperature appears here Appears when the buttons are locked Appears when the On Off timer Night setback or Auto off timer function is enabled appears when the timer is disabled by the centralized control system Appears when the Weekly timer is enabled Ap...

Page 5: ...rning use of the appliance by a person responsible for their safety This appliance is intended to be used by expert or trained users in shops in light industry and on farms or for commercial use by lay persons Do not use a leak detection additive Do not use refrigerant other than the type indicated in the manuals provided with the unit and on the nameplate Doing so may cause the unit or pipes to b...

Page 6: ...he outdoor unit will reduce the unit s efficiency Do not direct the airflow at plants or caged pets Ventilate the room frequently If the unit is operated continuously in a closed room for a long period of time the air will become stale In case of failure Warning Never remodel the air conditioner Consult your dealer for any repair or service Improper repair work can result in water leakage electric...

Page 7: ...e microcomputer functions in the following cases Air does not blow out when heating starts To prevent any cool air from escaping the indoor fan is gradually switched in sequence from faint airflow weak airflow set airflow according to the temperature rise of the blown out air Wait a moment until the airflow comes out naturally The fan is not moving at the set speed In some models the system switch...

Page 8: ...for the set temperature for Heat mode and the heating set temperature for Auto mode dual set points 4 The cooling and heating set temperatures can be set under the following conditions The cooling set temperature is greater than the heating set temperature The difference between the cooling and heating set temperatures is equal or greater than the minimum temperature difference that varies with th...

Page 9: ...on about 10 electric power can be saved Excessive cooling is bad for health It also results in the waste of electric power Clean the filter thoroughly If the screen of the air filter becomes clogged the airflow and air conditioning effect can be significantly reduced Further if the condition is left unattended failure can result It is particularly important to clean the filter at the beginning of ...

Page 10: ... unit operation was restarted during the heating and defrosting operation Wait for a while Heating operation starts after ending defrosting operation It runs briefly but soon stops The CHECK and check code flash on the liquid crystal display There are some obstacles at the air inlet and outlet of the indoor and outdoor units Rerun after removal The filter is filled with dust and dirt Rerun after c...

Page 11: ...unication related businesses If the air conditioner is used in any of the above mentioned environments frequent operational failure can be expected It is advisable to avoid these types of installation sites For further details consult with your dealer Regarding electrical work Caution The electrical work must be undertaken by a person who is qualified as an electrical engineer according to the tec...

Page 12: ...38 34 39 41 Filter Long life filter P80VLMD E P100VLMD E P125VLMD E Power source 220 240 V 50 Hz 220 230 V 60 Hz Cooling capacity 1 Heating capacity 1 kW 9 0 10 0 11 2 12 5 14 0 16 0 Dimension 2 Height mm 290 20 290 20 290 20 Width mm 1446 1750 1446 1750 1708 2010 Depth mm 634 710 634 710 606 710 Net weight kg 44 12 5 47 12 5 56 13 Fan Airflow rate Low Middle High m3 min 15 5 18 5 22 0 17 5 21 0 2...

Page 13: ...200VMH E P250VMH E Power source 3 N 380 415 V 50 60 Hz Cooling capacity 1 Heating capacity 1 kW 22 4 25 0 28 0 31 5 Dimension Height Width Depth mm 470 1250 1120 470 1250 1120 Net weight kg 100 100 Fan Airflow rate m3 min 58 0 72 0 External static pressure 3 Pa 380 V 110 220 110 220 400 415 V 130 260 130 260 Sound pressure level 5 dB A 380 V 42 50 400 415 V 44 52 Filter Long life filter option PEF...

Page 14: ...60 220 130 210 Sound pressure level dB A 380 V 39 42 40 44 400 V 40 43 40 45 415 V 40 44 41 46 Filter Long life filter option 1 Cooling Heating capacity indicates the maximum value at operation under the following condition Cooling Indoor 33 CDB 28 CWB Outdoor 33 CDB Heating Indoor 0 CDB 2 9 CWB Outdoor 0 CDB 2 9 CWB 2 The operating noise is the data that was obtained in an anechoic room PEFY P VM...

Page 15: ... V 50 Hz 60 Hz Cooling capacity 1 Heating capacity 1 kW 2 2 2 5 2 8 3 2 3 6 4 0 4 5 5 0 5 6 6 3 7 1 8 0 Dimension Height Width Depth mm 639 886 220 639 886 220 639 1006 220 639 1006 220 639 1246 220 639 1246 220 Net weight kg 21 21 24 25 29 29 Fan Airflow rate Low Middle High m3 min 4 5 5 5 6 5 4 5 5 5 6 5 6 5 7 5 9 0 8 0 9 5 10 0 10 0 12 0 14 0 11 0 13 0 15 5 External static pressure 2 Pa 20 40 6...

Page 16: ...y 1 Heating capacity 1 kW 7 1 8 0 8 0 9 0 9 0 10 0 Dimension Height Width Depth mm 250 1100 732 250 1100 732 250 1100 732 Net weight kg 32 32 32 Fan Airflow rate Low Middle High m3 min 13 5 16 0 19 0 14 5 18 0 21 0 14 5 18 0 21 0 External static pressure 2 Pa 35 50 70 100 150 35 50 70 100 150 35 50 70 100 150 Sound pressure level Low Middle High 3 measurement condition 1 dB A 25 29 33 26 29 34 26 ...

Page 17: ...ображается в нижней части ЖК экрана для функций которые работают в данном окне При централизованном управлении системой подсказка по функциям для заблокированных кнопок отображаться не будет Главное окно Главное меню Пт Комн Уст темп Режим Темп Вент Охлажд Авт Главн Основной экран Стрелка Страница Главное меню Угол㺃жалюзи㺃вент Lossnay Макс мощность Таймер Таймер на неделю Тих реж нaр Ⓖ Ⓗ Ⓘ Ⓙ Ⓖ Ⓗ Ⓘ...

Page 18: ...трализованном управлении заданной температурой Отображается при централизованном управлении функцией сброса фильтра Отображается при необходимости в обслуживании фильтра Комнатная температура Здесь отображается текущая комнатная температура Отображается когда кнопки заблокированы Отображается когда включена функция Таймер ВКЛ ВЫКЛ Ночной режим или Автоотключение таймера появляется когда таймер отк...

Page 19: ...ачено для использования лицами включая детей со сниженными физическими сенсорными и умственными способностями а также лицами без достаточных знаний и опыта за исключением случаев когда устройство используется под присмотром или руководством человека ответственного за безопасность таких лиц Данное действие должны выполнять эксперты или персонал прошедший специальное обучение а цехах помещениях легк...

Page 20: ...ва протрите это место сухой тканью Никогда не блокируйте и не закрывайте отверстия входа и выхода внутреннего или внешнего приборов Высокие предметы мебели находящиеся под внутренним прибором или крупногабаритные предметы например большие коробки помещенные вблизи внешнего прибора будут снижать эффективность его работы Не направляйте поток воздуха на растения или на животных или птиц в клетках Час...

Page 21: ...ти к неудовлетворительному процессу сгорания в горелке Микроэлектронное устройство функционирует в следующих случаях В начале режима отопления не происходит выдувание воздуха Чтобы предотвратить выдувание холодного воздуха внутренний вентилятор постепенно переключается последовательно от слабого потока воздуха к менее слабому и затем к выбранному уровню потока воздуха в соответствии с повышением т...

Page 22: ...ратур используются для режима обогрева и обогрева в режиме Авто две заданные точки 4 Заданные температуры охлаждения и обогрева должны соответствовать следующим условиям заданная температура охлаждения должна превышать заданную температуру обогрева разница между заданными температурами охлаждения и обогрева должна быть равна или больше минимальной разницы температуры которая зависит от модели внут...

Page 23: ... настройки вентиляции в следующем порядке Выкл Низ и Выс Настройка возможно только когда подключен блок Lossnay Выкл Низ Выс Вентилятор на некоторых моделях внутренних блоков может блокироваться при использовании с некоторыми моделями блоков вентиляции 4 Полезные советы Даже небольшие меры по уходу за кондиционером воздуха могут способствовать более эффективной работе прибора с точки зрения качест...

Page 24: ...срока службы в начале каждого прибора Срок службы фильтра зависит от места установки прибора и условий его эксплуатации Методы прочистки Смахните пыль легкими движениями или прочистите фильтр пылесосом Если фильтр сильно загрязнен промойте его в чуть теплой воде с растворенным в ней нейтральным детергентом а затем прополощите его в чистой воде После мытья фильтр необходимо просушить а затем устано...

Page 25: ...зм задержки возобновления работы прибора Подождите некоторое время Для защиты компрессора во внутренний прибор встроен механизм трехминутной задержки возобновления работы Поэтому иногда компрессор не приступает немедленно к работе Иногда он не приступает к работе в течение 3 минут Работа внутреннего прибора возобновилась во время операции обогрева и размораживания Подождите некоторое время Функция...

Page 26: ...е часто используются специальные распылители устанавливайте внутренний прибор строго горизонтально В противном случае может произойти утечка воды Предпринимайте достаточные меры по сокращению шума при установке кондиционеров в больницах или в помещениях связанных с телекоммуникацией Если кондицинер используется в любом из вышеуказанных местоположений возможны частые неполадки в функционировании пр...

Page 27: ...питания 220 240 B 50 Гц 220 230 B 60 Гц Охлаждающая мощность 1 Отопительная мощность 1 кВт 9 0 10 0 11 2 12 5 14 0 16 0 Габариты 2 Высота мм 290 20 290 20 290 20 Ширина мм 1446 1750 1446 1750 1708 2010 Глубина мм 634 710 634 710 606 710 Масса нетто кг 44 12 5 47 12 5 56 13 Вентилятор Скорость потока воздуха Низкая Средняя Высокая м3 мин 15 5 18 5 22 0 17 5 21 0 25 0 24 0 27 0 30 0 33 0 Низкая Сред...

Page 28: ...аждающая мощность 1 Отопительная мощность 1 кВт 22 4 25 0 28 0 31 5 Габариты Высота Ширина Глубина мм 470 1250 1120 470 1250 1120 Масса нетто кг 100 100 Вентилятор Скорость потока воздуха м3 мин 58 0 72 0 Внешнее статическое давление 3 Па 380 B 110 220 110 220 400 415 B 130 260 130 260 Уровень звукового давления 5 дБ A 380 B 42 50 400 415 B 44 52 Фильтр Долговечный фильтр опция Серия PEFY P VMHS E...

Page 29: ...B 40 44 41 46 Фильтр Долговечный фильтр опция 1 Охлаждающая Отопительная мощность указывает максимальное значение при эксплуатации прибора в следующих условиях Охлаждение Внутри 33 сухой термометр 28 влажный термометр Снаружи 33 сухой термометр Отопление Внутри 0 сухой термометр 2 9 влажный термометр Снаружи 0 сухой термометр 2 9 влажный термометр 2 Данные уровня шума при работе были получены в бе...

Page 30: ...Вт 2 2 2 5 2 8 3 2 3 6 4 0 4 5 5 0 5 6 6 3 7 1 8 0 Габариты Высота Ширина Глубина мм 639 886 220 639 886 220 639 1006 220 639 1006 220 639 1246 220 639 1246 220 Масса нетто кг 21 21 24 25 29 29 Вентилятор Скорость потока воздуха Низкая Средняя Высокая м3 мин 4 5 5 5 6 5 4 5 5 5 6 5 6 5 7 5 9 0 8 0 9 5 10 0 10 0 12 0 14 0 11 0 13 0 15 5 Внешнее статическое давление 2 Па 20 40 60 20 40 60 20 40 60 2...

Page 31: ...Глубина мм 250 1100 732 250 1100 732 250 1100 732 Масса нетто кг 32 32 32 Вентилятор Скорость потока воздуха Низкая Средняя Высокая м3 мин 13 5 16 0 19 0 14 5 18 0 21 0 14 5 18 0 21 0 Внешнее статическое давление 2 Па 35 50 70 100 150 35 50 70 100 150 35 50 70 100 150 Уровень звукового давления Низкая Средняя Высокая 3 условия измерения 1 дБ A 25 29 33 26 29 34 26 29 34 условия измерения 2 дБ A 29...

Page 32: ...onunu yerine getirebilmesi için gerekli yedek parça bulundurma süresidir Ürünün montajı için Mitsubishi Electric Turkey Elektrik Ürünleri A Ş yetkili servisine bayisine başvurunuz Servis İstasyonları ve Yedek Parça Temini Cihazınızın bakım onarım ve yedek parça ihtiyaçları için klimanızı satın aldığınız yetkili satıcıya başvurunuz Yetkili Servislerimizin listesine URL http klima mitsubishielectric...

Page 33: ......

Page 34: ... on the following EU regulations Low Voltage Directive 2014 35 EU Electromagnetic Compatibility Directive 2014 30 EU Machinery Directive 2006 42 EC Please be sure to put the contact address telephone number on this manual before handing it to the customer HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN WT07349X04 ...

Reviews: