2.2 Applicable System
This section explains the applicable system.
(1) Applicable master modules
For available master modules, visit the CC-Link Partner Association (CLPA)
website at:
http://www.cc-link.org/
REMARK
Check the specifications of the master module before use.
(2) Applicable combinations
The following table indicates usability according to the combinations of the
master modules, the mode setting and station information (station type) of the GX
Developer network parameters, and the mode select switch setting of the
module.
: Usable, : Unusable
GX Developer
Network Parameter Setting
Model Select Switch Setting
1
of AJ65VBTCU-
68DAN
Master Module
Mode setting
Station
information
(station type)
Ver. 1 remote device
station (Ver. 1 compatible
slave station)
Ver. 2 remote device
station (Ver. 2 compatible
slave station)
Remote net
ver. 1 mode
Remote device
station
Ver. 1 remote
device station
Remote net
ver. 2 mode
Ver. 2 remote
device station
Ver. 1 remote
device station
QJ61BT11
AJ61BT11
A1SJ61BT11
AJ61QBT11
A1SJ61QBT11
Remote net
additional mode
Ver. 2 remote
device station
Remote net
ver. 1 mode
Remote device
station
Ver. 1 remote
device station
Remote net
ver. 2 mode
Ver. 2 remote
device station
Ver. 1 remote
device station
2
QJ61BT11N
L26CPU-BT
LJ61BT11
Remote net
additional mode
Ver. 2 remote
device station
3
1 For details, refer to Section 4.3 and Section 4.4.
2 When there is a station number used as the ver. 2 remote device station in the existing system, set the
station number of the ver. 1 remote device station to be added before that station.
3 Set the station number of the ver. 2 remote device station to be added after the station numbers used in
the existing system.
Summary of Contents for AJ65VBTCU-68DAVN
Page 1: ...Digital Analog Converter Module type AJ65VBTCU 68DAVN User s Manual ...
Page 2: ......
Page 6: ...A 4 A 4 CONDITIONS OF USE FOR THE PRODUCT ...
Page 13: ...A 11 A 11 MEMO ...
Page 18: ...2 2 2 2 MELSEC A 2 SYSTEM CONFIGURATION 2 Remote net ver 2 mode remote net additional mode 2 ...
Page 41: ...3 19 3 19 MELSEC A 3 SPECIFICATION MEMO ...
Page 77: ...5 11 5 11 MELSEC A 5 PROGRAMMING 2 Program example ...
Page 79: ...5 13 5 13 MELSEC A 5 PROGRAMMING ...
Page 82: ...5 16 5 16 MELSEC A 5 PROGRAMMING ...
Page 84: ...5 18 5 18 MELSEC A 5 PROGRAMMING Remote registers RWw RWr ...
Page 92: ...5 26 5 26 MELSEC A 5 PROGRAMMING Remote registers RWw RWr ...
Page 99: ...5 33 5 33 MELSEC A 5 PROGRAMMING MEMO ...
Page 111: ......