Encoder input option selection
194
ROLL TO ROLL FUNCTION RELATED PARAMETERS
9.5
Encoder input option selection
Select the option (plug-in option / control terminal option) used for the motor (encoder) signal input and the option used for the
line speed command / actual line speed input.
• Select the option used for the motor (encoder) signal input and the option used for the line speed command / actual line
speed input. (Plug-in option / control terminal option)
• The options are selected according to the setting in
Pr.862 Encoder option selection
.
∗1
When two or more options among the FR-A8AP, FR-A8APR, FR-A8AL, and FR-A8APS are installed, the option with highest priority is enabled.
FR-A8AL > FR-A8APS > FR-A8APR > FR-A8AP
∗2
When the option is not installed, the pulse input value "0" is applied to the operation.
∗3
Line speed command / line speed input using the FR-A8APR is invalid.
NOTE
• When the same option is used for the signal input from the motor (encoder) and the line speed command input (
Pr.361
) or
actual line speed input (
Pr.362
), the signal input from the motor (encoder) is enabled.
Pr.
Name
Initial value
Setting
range
Description
862
C242
Encoder option selection
0
0
Signals from the motor (encoder) is input through the
plug-in option (FR-A8AP/FR-A8AL/FR-A8APR/FR-
A8APS).
1
Signals from the motor (encoder) is input through the
control terminal option (FR-A8TP).
Plug-in option
Control terminal
option
Pr.862 = "0"
Pr.862 = "1"
Motor (encoder)
signal
Line speed
command /
actual line speed
Motor (encoder)
signal
Line speed
command /
actual line speed
Installed
Installed
Plug-in option
Control terminal
option
Control terminal
option
Plug-in option
Not installed
Plug-in option
—
—
Plug-in option
Not installed
Installed
—
Control terminal
option
Control terminal
option
—
Not installed
—
—
—
—
Summary of Contents for A800 Plus Series
Page 240: ...239 MEMO ...