16
PARAMETER LIST
519
S-pattern time at a
completion of
deceleration
0.1 to 2.5s
0.1s
522
Output stop frequency 0 to 590Hz, 9999 9999
539
MODBUS RTU
communication check
time interval
0 to 999.8s,
9999
9999
541
Frequency command
sign selection
0, 1
0
547
USB communication
station number
0 to 31
0
548
USB communication
check time interval
0 to 999.8s,
9999
9999
549
Protocol selection
0, 1
0
550
NET mode operation
command source
selection
0, 1, 9999
9999
551
PU mode operation
command source
selection
1 to 3, 9999
9999
552
Frequency jump range 0 to 30Hz, 9999 9999
553
PID deviation limit
0 to 100%, 9999 9999
554
PID signal operation
selection
0 to 3, 10 to 13
0
555
Current average time
0.1 to 1.0s
1s
556
Data output mask time 0 to 20s
0s
557
Current average value
monitor signal output
reference current
0 to 500A
Inverter
rated
current
0 to 3600A
560
Second frequency
search gain
0 to 32767,
9999
9999
561
PTC thermistor
protection level
0.5 to 30k
Ω
,
9999
9999
563
Energization time
carrying-over times
(0 to 65535)
0
564
Operating time
carrying-over times
(0 to 65535)
0
565
Second motor
excitation current break
point
0 to 400Hz,
9999
9999
566
Second motor
excitation current low-
speed scaling factor
0 to 300%, 9999 9999
569
Second motor speed
control gain
0 to 200%, 9999 9999
570
Multiple rating setting
0 to 3
2
571
Holding time at a start
0 to 10s, 9999
9999
573
4 mA input check
selection
1 to 4, 11 to 14,
21 to 24, 9999
9999
574
Second motor online
auto tuning
0 to 2
0
575
Output interruption
detection time
0 to 3600s,
9999
1s
576
Output interruption
detection level
0 to 590Hz
0Hz
577
Output interruption
cancel level
900 to 1100%
1000%
592
Traverse function
selection
0 to 2
0
593
Maximum amplitude
amount
0 to 25%
10%
594
Amplitude
compensation amount
during deceleration
0 to 50%
10%
595
Amplitude
compensation amount
during acceleration
0 to 50%
10%
596
Amplitude acceleration
time
0.1 to 3600s
5s
597
Amplitude deceleration
time
0.1 to 3600s
5s
598
Undervoltage level
175 to 215V/
350 to 430V
,
9999
9999
599
X10 terminal input
selection
0, 1
0
600
First free thermal
reduction frequency 1
0 to 590Hz,
9999
9999
601
First free thermal
reduction ratio 1
1 to 100%
100%
602
First free thermal
reduction frequency 2
0 to 590Hz,
9999
9999
603
First free thermal
reduction ratio 2
1 to 100%
100%
604
First free thermal
reduction frequency 3
0 to 590Hz,
9999
9999
606
Power failure stop
external signal input
selection
0, 1
1
607
Motor permissible load
level
110 to 250%
150%
608
Second motor
permissible load level
110 to 250%,
9999
9999
609
PID set point/deviation
input selection
1 to 5
2
610
PID measured value
input selection
1 to 5
3
Pr.
Name
Setting
range
Initial
value
611
Acceleration time at a
restart
0 to 3600s,
9999
9999
617
Reverse rotation
excitation current low-
speed scaling factor
0 to 300%, 9999 9999
635
Cumulative pulse clear
signal selection
0 to 3
0
636
Cumulative pulse
division scaling factor
1 to 16384
1
637
Control terminal option-
Cumulative pulse
division scaling factor
1 to 16384
1
638
Cumulative pulse
storage
0 to 3
0
639
Brake opening current
selection
0, 1
0
640
Brake operation
frequency selection
0, 1
0
641
Second brake
sequence operation
selection
0, 7, 8, 9999
0
642
Second brake opening
frequency
0 to 30Hz
3Hz
643
Second brake opening
current
0 to 400%
130%
644
Second brake opening
current detection time
0 to 2s
0.3s
645
Second brake operation
time at start
0 to 5s
0.3s
646
Second brake operation
frequency
0 to 30Hz
6Hz
647
Second brake operation
time at stop
0 to 5s
0.3s
648
Second deceleration
detection function
selection
0, 1
0
650
Second brake opening
current selection
0, 1
0
651
Second brake operation
frequency selection
0, 1
0
653
Speed smoothing
control
0 to 200%
0
654
Speed smoothing cutoff
frequency
0 to 120Hz
20Hz
655
Analog remote output
selection
0, 1, 10, 11
0
656
Analog remote output 1
800 to 1200%
1000%
657
Analog remote output 2
1000%
658
Analog remote output 3
1000%
659
Analog remote output 4
1000%
660
Increased magnetic
excitation deceleration
operation selection
0, 1
0
661
Magnetic excitation
increase rate
0 to 40%, 9999 9999
662
Increased magnetic
excitation current level 0 to 300%
100%
663
Control circuit
temperature signal
output level
0 to 100°C
0°C
665
Regeneration
avoidance frequency
gain
0 to 200%
100%
668
Power failure stop
frequency gain
0 to 200%
100%
673
SF-PR slip amount
adjustment operation
selection
2, 4, 6, 9999
9999
674
SF-PR slip amount
adjustment gain
0 to 500%
100%
675
User parameter auto
storage function
selection
1, 9999
9999
679
Second droop gain
0 to 100%, 9999 9999
680
Second droop filter time
constant
0 to 1s, 9999
9999
681
Second droop function
activation selection
0 to 2, 10, 11,
20 to 22, 9999
9999
682
Second droop break
point gain
0.1 to 100%,
9999
9999
683
Second droop break
point torque
0.1 to 100%,
9999
9999
684
Tuning data unit
switchover
0, 1
0
686
Maintenance timer 2
0(1 to 9998)
0
687
Maintenance timer 2
warning output set time 0 to 9998, 9999 9999
688
Maintenance timer 3
0(1 to 9998)
0
689
Maintenance timer 3
warning output set time 0 to 9998, 9999 9999
690
Deceleration check time 0 to 3600s,
9999
1s
692
Second free thermal
reduction frequency 1
0 to 590Hz,
9999
9999
693
Second free thermal
reduction ratio 1
1 to 100%
100%
694
Second free thermal
reduction frequency 2
0 to 590Hz,
9999
9999
Pr.
Name
Setting
range
Initial
value
695
Second free thermal
reduction ratio 2
1 to 100%
100%
696
Second free thermal
reduction frequency 3
0 to 590Hz,
9999
9999
699
Input terminal filter
5 to 50ms, 9999 9999
702
Maximum motor
frequency
0 to 400Hz,
9999
9999
706
Induced voltage
constant (phi f)
0 to 5000mV/
(rad/s), 9999
9999
707
Motor inertia (integer)
10 to 999, 9999 9999
711
Motor Ld decay ratio
0 to 100%, 9999 9999
712
Motor Lq decay ratio
0 to 100%, 9999 9999
717
Starting resistance
tuning compensation
0 to 200%, 9999 9999
721
Starting magnetic pole
position detection pulse
width
0 to 6000
μ
s,
10000 to
16000
μ
s, 9999
9999
724
Motor inertia (exponent) 0 to 7, 9999
9999
725
Motor protection current
level
100 to 500%,
9999
9999
738
Second motor induced
voltage constant (phi f)
0 to 5000mV/
(rad/s), 9999
9999
739
Second motor Ld decay
ratio
0 to 100%, 9999 9999
740
Second motor Lq decay
ratio
0 to 100%, 9999 9999
741
Second starting
resistance tuning
compensation
0 to 200%, 9999 9999
742
Second motor magnetic
pole detection pulse
width
0 to 6000
μ
s,
10000 to
16000
μ
s, 9999
9999
743
Second motor
maximum frequency
0 to 400Hz,
9999
9999
744
Second motor inertia
(integer)
10 to 999, 9999 9999
745
Second motor inertia
(exponent)
0 to 7, 9999
9999
746
Second motor
protection current level 100 to 500%, 9999 9999
747
Second motor low-
speed range torque
characteristic selection
0, 9999
9999
753
Second PID action
selection
0, 10, 11, 20, 21,
50, 51, 60, 61,
70, 71, 80, 81,
90, 91, 100,
101, 1000,
1001, 1010,
1011, 2000,
2001, 2010,
2011
0
754
Second PID control
automatic switchover
frequency
0 to 590Hz,
9999
9999
755
Second PID action set
point
0 to 100%, 9999 9999
756
Second PID
proportional band
0.1 to 1000%,
9999
100%
757
Second PID integral
time
0.1 to 3600s,
9999
1s
758
Second PID differential
time
0.01 to 10.00s,
9999
9999
759
PID unit selection
0 to 43, 9999
9999
760
Pre-charge fault
selection
0, 1
0
761
Pre-charge ending level 0 to 100%, 9999 9999
762
Pre-charge ending time 0 to 3600s,
9999
9999
763
Pre-charge upper
detection level
0 to 100%, 9999 9999
764
Pre-charge time limit
0 to 3600s,
9999
9999
765
Second pre-charge
fault selection
0, 1
0
766
Second pre-charge
ending level
0 to 100%, 9999 9999
767
Second pre-charge
ending time
0 to 3600s,
9999
9999
768
Second pre-charge
upper detection level
0 to 100%, 9999 9999
769
Second pre-charge
time limit
0 to 3600s, 9999
9999
774
Operation panel
monitor selection 1
1 to 3, 5 to 14,
17 to 20, 22 to 36,
38 to 46, 50 to 57,
61, 62, 64, 67,
71 to 75, 87 to 98,
100, 9999
9999
775
Operation panel
monitor selection 2
9999
776
Operation panel
monitor selection 3
9999
777
4 mA input check
operation frequency
0 to 590Hz, 9999
9999
778
4 mA input check filter
0 to 10s
0s
779
Operation frequency
during communication
error
0 to 590Hz, 9999
9999
788
Low speed range
torque characteristic
selection
0, 9999
9999
Pr.
Name
Setting
range
Initial
value
Downloaded from