Basic operation procedure (PU operation)
82
4.2
Basic operation procedure (PU operation)
POINT
POINT
• Where is the frequency command source?
- The frequency set in the frequency setting mode of the operation panel
→
Refer to 4.2.1. (Refer to
- The ON/OFF switches connected to terminals
→
Refer to 4.2.2. (Refer to
.)
- Voltage input signals
→
Refer to 4.2.3. (Refer to
- Current input signals
→
Refer to 4.2.4. (Refer to
4.2.1
Operating at a set frequency (example:
operating at 30 Hz)
POINT
POINT
• Use the operation panel to give a start command and a frequency command. (PU operation)
Parameters referred to
Pr.7 Acceleration time, Pr.8 Deceleration time
Pr.79 Operation mode selection
Operation example
Operate at 30 Hz.
Operation
1.
Screen at power-ON
The monitor display appears.
2.
Changing the operation mode
Press
to choose the PU operation mode. [PU] indicator is on.
3.
Setting the frequency
Turn
until the target frequency, "30.00 Hz", appears.
Press [SET] to enter the frequency. "Completed" flickers. After about 3 s of flickering, the indication goes back to "0.00 Hz"
(monitor display).
4.
Start
→
acceleration
→
constant speed
Press
or
to start running. The frequency value on the indication increases in
Pr.7 Acceleration time,
and
"30.00 Hz" appears.
(To change the set frequency, perform the operation in above step 3. The previously set frequency appears.)
5.
Deceleration
→
stop
Press
to stop. The frequency value on the indication decreases in
Pr.8 Deceleration time,
and the motor stops
rotating with "0.00 Hz" displayed.