background image

MIO-6706 Quick Start Guide

9

Chapter 3

Wi-SUN Module Specifications

3.1  Wi-SUN Module PCB Size

The Wi-SUN PCB size is 18 x 32 mm.

3.2  Specifications

Table 3   

Wi-SUN Module Specifications

Frequency Band

FCC: 902~928 MHz, NCC: 920~925MHz

Maximum Power 
Consumption

400 mW 

Link Rate

Maximum is 300 kbps

Also support 50 kbps, 100 kbps, 150 kbps

TX

FCC maximum peak conducted output power: 

18.95 dBm at 50 kbps

18.96 dBm at 100 kbps

19.02 dBm at 150 kbps

18.99 dBm at 300 kbps

NCC maximum peak conducted output power:

18.98 dBm at 50 kbps

18.92 dBm at 100 kbps

11.28 dBm at 150 kbps

8.37 dBm at 300 kbps

RX

Sensitivity in Wi-SUN mode:

  -98 dBm at 50 kbps

  -96 dBm at 100 kbps

  -94 dBm at 150 kbps

  -91 dBm at 300 kbps

Antenna

Defined by customer

Summary of Contents for MIO-6706

Page 1: ...Copyright 2021 MitraStar Technology Corp Edition 1 5 2021 MIO 6706 Development Kit Quick Start Guide ...

Page 2: ...e Dimensions 4 2 2 Connecting the Boards and Powering Up 4 2 3 Connecting to a Computer and Starting Up 4 2 4 Other Information 7 2 5 Regulations Certifications 8 Chapter 3 Wi SUN Module Specifications 9 3 1 Wi SUN Module PCB Size 9 3 2 Specifications 9 3 3 Other Information 10 3 4 Power Tree 10 3 5 GPIO for Sub 1G TX RX Switching 10 3 6 Regulation Certifications 10 ...

Page 3: ...ed to be integrated with IoT sensors and gateways for data transfer The Wi SUN network technology follows IEEE 802 15 4g e and supports most available sub GHz frequencies The Wi SUN solution provides the advantages of long range applications low power higher speed hybrid mesh and cost effectiveness It provides open standards based secure interoperable communications for large scale IoT Smart Utili...

Page 4: ...ower source to power up the Development Kit 2 3 Connecting to a Computer and Starting Up Follow the steps below to connect the Development Kit to a computer and start it up 1 Power up the Development Kit by following the steps in Section 2 2 on page 4 2 Connect the 4 pin UART port of the Development Kit to your computer s USB port with an RS232 cable Make sure the computer is powered on 3 You can ...

Page 5: ...Chapter 2 The Development Kit MIO 6706 Quick Start Guide 5 Figure 1 New COM Port 5 Open Tera Term and click Setup Serial port Figure 2 Tera Term Setup Serial port ...

Page 6: ...de 6 6 Select the new COM port in the Port field Figure 3 Select Port 7 Set the baud rate in the Speed field to 115200 Click OK to save the settings Figure 4 Set Speed 8 The following screen appears You can now start using commands for the Development Kit ...

Page 7: ...ete 2 4 Other Information Table 1 Other Information 1 Environmental Requirements Operating Temp 20 C 70 C Storage Temp 30 C 85 C Operating Humidity 10 to 90 Non Condensing Storage Humidity 10 to 95 Non Condensing 2 Other Requirements Timer function Heat resistance and fireproofing ...

Page 8: ...2 5 Regulations Certifications Regulations draft report only Table 2 Regulations Certifications COUNTRY REGION CERTIFICATION STANDARD FREQUENCY BAND BOM U S A FCC FCC Part 15C 15 247 902 928 MHz 902 928 MHz Taiwan NCC LP0002 5 8 Taiwan Asia Regions 920 925 MHz ...

Page 9: ... mW Link Rate Maximum is 300 kbps Also support 50 kbps 100 kbps 150 kbps TX FCC maximum peak conducted output power 18 95 dBm at 50 kbps 18 96 dBm at 100 kbps 19 02 dBm at 150 kbps 18 99 dBm at 300 kbps NCC maximum peak conducted output power 18 98 dBm at 50 kbps 18 92 dBm at 100 kbps 11 28 dBm at 150 kbps 8 37 dBm at 300 kbps RX Sensitivity in Wi SUN mode 98 dBm at 50 kbps 96 dBm at 100 kbps 94 d...

Page 10: ...e 3 6 Regulation Certifications Regulations EVT Test only no certificate Table 4 Other Information 1 Environmental Requirements Operating Temp 20 C 70 C Storage Temp 30 C 85 C Operating Humidity 10 to 90 Non Condensing Storage Humidity 10 to 95 Non Condensing 2 Other Requirements Timer function Heat resistance and fireproofing Table 5 Regulations CERTIFICATION STANDARD FCC FCC Part 15C 15 247 NCC ...

Page 11: ...for compliance could void the user s authority to operate this equipment This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation FCC Radiation Exposure Statem ent This equipment complies wi...

Page 12: ...安全及干擾合法通信 經發現有干擾現象時 應立即停用 並 改善至無干擾時方得繼續使用 前述合法通信 指依電信管理法規定作業之無線電通信 低功率射頻器材須忍受合 法通信或工業 科學及醫療用電波輻射性電機設備之干擾 本模組於取得認證後將依規定於模組本體標示審驗合格標籤 並要求平台廠商於平台上標示 本產品內含射頻模 組 Antenna information Antenna 1 No Manufacturer Model No Antenna Type Antenna Gain 1 HongBo 290 10540 PCB Antenna 2 05 dBi Antenna 2 No Manufacturer Model No Antenna Type Antenna Gain 1 HongBo 56 001 000023Z PCB Antenna 1 01 dBi ...

Reviews: