![Mitel Base Station Installation Manual Download Page 27](http://html.mh-extra.com/html/mitel/base-station/base-station_installation-manual_1807626027.webp)
32/1531-ANF 901 43 Uen B2 2016-04-01
Installation Guide
Base Station
25
Appendix A: RFP Power Consumption
The table below show power consumption for a base station connected to and powered
from the PBX.
The maximum cable length for base stations connected to the PBX must
not
exceed
1700 meters.
A.1
IPBS4x0, BS3x2 and BS3x0 R4H and later
Table 1
Power consumption (watts) of base stations and cabling when powered from the PBX
Cable
length
(metres)
0.4 mm wire size
(
)
0.5 mm wire size
(
)
0.6 mm wire size
(
)
Without
EPP
With
EPP
Without
EPP
With
EPP
Without
EPP
With
EPP
0
2.0
2.0
2.0
2.0
2.0
2.0
100
2.0
2.0
2.0
2.0
2.0
2.0
200
2.1
2.0
2.0
2.0
2.0
2.0
300
2.1
2.1
2.1
2.0
2.0
2.0
400
2.1
2.1
2.1
2.1
2.1
2.0
500
2.2
2.1
2.1
2.1
2.1
2.0
600
2.2
2.1
2.1
2.1
2.1
2.1
700
2.3
2.2
2.2
2.1
2.1
2.1
800
2.3
2.2
2.2
2.1
2.1
2.1
900
2.4
2.2
2.2
2.1
2.1
2.1
1000
2.5
2.3
2.3
2.2
2.2
2.1
1100
2.6
2.3
2.3
2.2
2.2
2.1
1200
2.7
2.3
2.3
2.2
2.2
2.1
1300
2.8
2.4
2.4
2.2
2.2
2.1
1400
2.9
2.4
2.4
2.2
2.2
2.1
1500
3.2
2.5
2.4
2.3
2.3
2.2
1600
3.7
2.5
2.5
2.3
2.3
2.2
1700
-
2.6
2.5
2.3
2.3
2.2