Description of barriers and parameters modification
barrier ID
Displays the 485 serial addresses that can be controlled from a single COM.
The values entered in this barrier cannot be changed.
TX AND RX FREQ barrier
Displaying the frequency of the TX antenna and the RX antenna (range from 0 to 249 Hz) for each
connected module, 16 frequencies are set as standard.
For correct operation, the two TX and RX antennas must have the same frequency.
The program updates the values even if one of the two frequencies is changed. For example, by
changing only the freq. TX, the program also changes the freq. RX and vice versa.
To change the frequency place the mouse on the cell of the address you want to change (TX or RX)
and click once (figure 1).
Wait for the control window to open (figure 2) and enter a value between 0 and 249 and click OK
(figure 3).
In this phase the new value set on the TX Freq and RX Freq cells will be displayed.
To save the modification, click with the mouse on the red cell of the address you are configuring
(figure 4).
TX LEVEL barrier
Displays the 4dB attenuation of the transmission signal for each address.
To activate or deactivate this parameter, position the mouse on the TX Level cell that you want to
modify and click once (figure 1). Wait for the activation of the curtain control (figure 2), click a second
time and select one of the two values 0 db or + 4db (figure 3).
With the value 0 db the signal is attenuated by 4 dB.
To save the modification, click with the mouse on the red cell of the address you are configuring
(figure 4).