TOWER MAGNUS
Installation and user manual
Page 20 of 32
Introduction
The microwave device consists of two TX and RX units to be positioned at opposite ends of the
protected area. The TX unit emits electromagnetic waves in the direction of the RX unit that
receives them, processes them and translates them into an electrical signal that is analyzed.
The intruder who crosses the detection area (ZR) causes a change in the signal.
The intensity and type of signal depend on the following factors:
- size and mass of the intruder who crosses the ZR
- speed and time of crossing the ZR
- conformation and soil conditions
Features and consumption
Detection speed
From 0,1 to 10,0 m/s
Power supply
From 12 to 36 Vdc
Consumption
Module TX 70 mA - module RX 110 mA
Recovery time after alarm notification
10 s
Duration of the report
5 s
Operating frequency
From 24.000 to 24.250 GHz (K band)
Selectable frequencies
By dip-switch: 16
By software: 250
Maximum lobe height
2,5 m
Maximum lobe height and aperture
50 m range: 0,6 m at 25 m
100 m range: 1,2 m at 50 m
Installation height
From 80 to 90 cm from the ground
3,0 m
20
cm
2,0 m
50
cm
1,0 m
70
cm
90
cm
Non-detection zones