Page 1: ...7 USER S RECORD Purchase Date Serial No Rear Panel of the Machine Dealer s Name Dealer s Address Dealer s Tel Fax Notes Please attach the proof of purchase USER S MANUAL MODEL SUPER200 200P MITEC WELDING EQUIPMENT SHENZHEN CO LTD ...

Page 2: ... burnt badly 9 Welding spot becoming black It means the welding spot is oxygenated without good protection and please check the followings 9 1 Make sure the argon cylinder is open and has enough pressure which should be above 0 5 MPa 9 2 Make sure the pressure valve is open and has enough flow In order to save gas you can choose different flow according to the different welding current but it may ...

Page 3: ...t preventive measures 2 4 Assure the ground screw is well connected There is a ground screw with the symbol at the rear panel of the unit Choose section of inducting cable over 6mm 2 and reliably grounding to prevent from static electricity and leaking SUPER Series User s Manual 2 SECURITY CAUTION Please make good protection as there will be possibility of harm during arc welding process For more ...

Page 4: ... Earth clamp 2 Torch 3 Air Pressure Meter 4 Gas Hose SUPER Series User s Manual 4 PANEL DESCRIPTION SUPER200P No Name 1 Current 2 Pre flow Time 3 Pulse Width 4 Pulse Frequency 5 Current Display Meter 6 Electrode holder connector 7 Torch Connector 8 Torch Switch Connector 9 Peak current regulation 10 Down slope Time 11 Clear Width 12 Post gas time regulation 13 MMA TIG CUT Selection 14 AC DC Select...

Page 5: ...er to reduce the voltage drop cable of bigger section is suggested If cable is too long it may affect the performance of the power system as well as other properties so we recommend you to use the configured length 1 Be sure the vents are not blocked lest cooling system will not work 2 Well connect the protection gas source Gas supply includes gas cylinder argon regulator and gas hose Connecting p...