Cleaning and Maintenance 

In principle, all cleaning and maintenance works must be performed after the stunner has 
been switched off. Dirty and consumed electrodes lead to poor skin contact and do not 
ensure optimum stunning. 
 
 

5.1 Safety Information 
DANGER! 
Live Machine Parts. 

Danger to Life. 

 Disconnect the Electro Sheep Stunner from the mains supply before each operation and 

protect against unintended reactivating. 
 

WARNING! 
Risk of accident caused by insufficiently qualified personnel 

Danger to Life and most severe injuries are possible. 

 The Electro Sheep Stunner may only be operated, maintained and repaired by instructed 

and authorized service personnel. 
 
 

5.2 Daily Cleaning 

 Only use the cleaning detergents especially designed for use in the food industry. 

1. Disconnect the Electro Sheep Stunner from the mains supply. 
2. Clean the Electro Sheep Stunner only manually by using customary detergents and 
disinfectants. 
3.. Clean the dirty electrodes with a steel brush. 
4. Keep the electrodes bare. 
5. Store the Electro-Stun-Tong in a warm and dry place for its next application. 
 

5.3 Periodic Inspection of Electrical Equipment 

In accordance with the accident prevention regulation “Electrical installations and equipment” 
and the operational safety rules the operator is obliged to ensure that all electrical machinery 
and installations are regularly checked for electrical safety. Periodic inspections of non-
stationary electrical machinery and equipment that is used in slaughtering and cutting plants 
must be carried out at intervals of six months in accordance with DIN VDE 0701-0702/EN 
60204-1. The electrical test must be carried out by an electrically skilled person in 
the sense of the accident prevention regulation “Electrical installations and equipment” or by 
an electrically instructed person. We recommend that you should document the inspections 
and test results in a test logbook. This will enable you at any time to further proof that you 
have inspected your machinery and equipment in accordance with requirements. Service at 
MEFE would like to give you the option to arrange for the next periodic inspection of your 
machinery or equipment to be carried out at our warehouse. Our service includes a complete 
inspection of the electrical system with inspection report and test sticker. If you are interested 
in arranging for a periodic inspection at our warehouse or by a service technician on-site, 
contact our sales staff. Please refer to the company information for address and telephone 
numbers. 
 

Summary of Contents for CAT 44SHP

Page 1: ...1800 66900 6 www mefe com au Unauthorized reproduction or use of information herein is strictly forbidden SHEEP STUNNER 1 CAT 44SHP ...

Page 2: ... Explanation of Signal Words and Symbols in Use 20 2 4 1 Operational Instructions for Safety Precautions 20 2 4 2 Used Danger Signs 20 2 5 Remaining Rest Risk 20 3 Technical Description 22 3 1 Technical Features 22 3 2 Overview 23 4 Operating and Stunning 24 4 1 Safety Information 24 4 2 Operating with the Electro Stun Tong 24 4 3 Performing the stunning 24 5 Cleaning and Maintenance 25 5 1 Safety...

Page 3: ...available at an extra charge and can be obtained from our sales department the address and telephone number of which is indicated further ahead in the imprint 1 3 Liability and Warranty All specifications and instructions for operation and maintenance of this Electro Sheep Stunner are made to the best of our knowledge taking into account our expertise and experiences so far For any legal claims wh...

Page 4: ...1 All our electrical machinery and equipment is tested for electrical safety prior to commissioning and following modification or repair in our factory in accordance with the electrical engineering rules as per DIN VDE 0701 0702 EN 60204 1 A test sticker is attached This test sticker indicates when the next periodic inspection must be carried out The inspection interval for machinery and equipment...

Page 5: ... each operation and protect against unintended reactivating 3 Technical Description The stunning unit consists of a stunner and the CAT 44SH HANDPIECE The stunning unit has been manufactured in compliance with DIN EN 60335 2 87 German Industry Standard and the Animal Protection Slaughter Decree 1099 2004 German TierSchlV of 25 November 1999 The Electro Stun Tong complies with the quality standards...

Page 6: ... itis used together with a stunner for stunning of sheep lambs and goats Details of the operation and implementation of electrical stunning refer to the operating instructions of the stunner 4 3 Performing the stunning The Electro Sheep Stunner is for head stunning application Connect the Electro Sheep Stunner with the stunner Place the electrodes of the Electro Sheep Stunner on both sides of the ...

Page 7: ...f Electrical Equipment In accordance with the accident prevention regulation Electrical installations and equipment and the operational safety rules the operator is obliged to ensure that all electrical machinery and installations are regularly checked for electrical safety Periodic inspections of non stationary electrical machinery and equipment that is used in slaughtering and cutting plants mus...

Page 8: ...unner must be performed in accordance with applicable legal regulations of each country Dismantle the Electro Sheep Stunner Refuse all material separately to deposit and recycling Please follow the instructions below for the sake of pollution control and your own safety Observe the local provisions on pollution control Dispose of all materials in a safe and environmentally friendly manner Separate...

Page 9: ...www mefe com au Unauthorized reproduction or use of information herein is strictly forbidden 9 PLUG 100 017 047 SPIRAL CABLE 164 101 004 CABLE GLAND CAT 44SH 3 ELECTRODE NUT WASHER CAT 44SHP 1 HANDLE ONLY CAT 44SHP2 ...

Reviews: