3.3.7
Reflector test
After a reflector foil is measured (AL QU 16.5, AL QU 33, AL RE 30x50,
AL RE 30x60, AL RE 30x70 and AL RE 30x100), the results menu
optionally offers the “Reflector test” (s. Fig. 31, p. 35). The reflector
test helps to:
Determine reflector foil/plate size
Assess the condition of the reflector
To perform a reflector test, a second run over reflector is necessary:
This run must be conducted along the long side of reflector (change
measurement direction by 90 degrees). Press search button to
determine reflector position. Once the edge of the foil/plate is
determined, measurement can be started and the probe has to be
moved slowly over reflector.
Directly after completing the measurement the following parameters
are displayed (s. Fig. 32):
“Coefficient” (material quality): Repeated calculation of material
quality (s. sec. 3.3.6, p. 35) from the data of a run along the
long and short side of the reflector
“Calc. size” (calculated size):
Calculated width and length of the reflector
Reflector test
1.
Change measurement
direction by 90 degrees
2.
Press search button to
find edge of reflector
3.
Start measurement and
move probe slowly over
the reflector
Fig. 32 Reflector test result