L’installation doit être effectuée par une personne qualifiée. 

The installation must be done by a qualified person. 

1.  Remove the packaging of the cold unit (box and protective plastic). 
2.  Remove the protective film from the body 

(fig. 1)

 

3.  Place the cooler, provide a clearance of at least 10 cm 

(fig. 2)

 

4. 

Connect the water supply

. The water pressure must be between 3 and 4 bar. 

5.  Remove the cover by unscrewing the screw on the cover 

(fig. 5)

 

6.  Lift the lid of the refrigeration tank 
7.  Fill the cooling tank with water until the immersion of the stainless steel coils 

(fig. 6)

 

8.  Replace the insulating cover on the refrigeration tank 
9.  Connect the water inlet, CO2 (for the G80 EF/ET/EG), and the outlets to your equipment 
10. Open water inlet 
11. Dispense water through the distribution device

Installation is completed for the cold version. For the sparkling version continue on next page

.

 

1.  Oter l’emballage du groupe froid (carton et plastique de protection). 
2.  Enlever le film protecteur de la carrosserie 

(fig. 1)

 

3.  Placer le refroidisseur, prévoir un espace libre pour la ventilation d'au moins 10 cm 

(fig. 2)

 

4. 

Raccorder l'arrivée d'eau. 

La pression de l'eau doit être comprise entre 3 et 4 bars. 

5.  Retirer le couvercle en dévissant la vis située sur le couvercle 

(fig. 5)

 

6.  Soulever le couvercle de la cuve de réfrigération 
7.  Remplir la cuve de réfrigération en eau jusqu’à l’immersion totale des serpentins inox 

(fig. 6)

 

8.  Remettre le couvercle isolant sur la cuve de réfrigération 
9.  Connecter les tuyaux d’arrivée d’eau, de CO2 (pour les G80 EF/ET/EG), et les sorties à votre équipement 
10. Ouvrir l’arrivée d’eau
11. Faire couler de l’eau par les moyens de distribution 

L’installation est terminée pour la version non gazeuse. Pour la version gazeuse continuer page suivante. 

Nous recommandons vivement l’installation d’un kit réducteur de pression réglé à 3 bars et 
d’un water block préréglé en position 2 pour se bloquer après une utilisation de 10 L d’eau en 
continu (fig. 3) ou d’un Watersafe pour les versions électriques (fig. 4)  

We strongly recommend the installation of a pressure reducer set at 3 bar and a water block 
preset in position 2 to lock after using 10 L of water continuously (fig.3) or a Watersafe for 
electrical versions (fig.4) 

INSTALLATION

 

INSTALLATION

 

Lors de l’installation des fontaines, Mistral préconise de remplacer le flexible d’alimentation par un 

tube neuf ou de réaliser une désinfection avec un produit bactéricide comme le SANIPURE® qui 

réduit les risques de prolifération bactérienne.

Une opération de désinfection des conduits internes doit être effectuée à l’installation du 

refroidisseur, ou si une intervention est effectuée sur le sytème hydraulique ou au moins tous les ans.

During water coolers installation, Mistral recommend to replace the water alimentation hosepipe with 

a new pipe or to disinfect it with an antibacterial product like SANIPURE® which reduces the risks of 

bacterial proliferation. A disinfection of internal pipes is required before the installation, or if an 

intervention is done on the hydraulic system (ex: changing filter) or at least every year.

Summary of Contents for Horeca G80

Page 1: ...el d installation Manual Syst mes professionnels HORECA G80 Rev 8 ZI Bois de l Epine 2 avenue Ambroise Croizat 91130 Ris Orangis FRANCE tel 33 0 1 60 79 37 61 fax 33 0 1 60 79 18 26 www mistralcoolers...

Page 2: ...aine ne sont pas pratiquer par des enfants Si le cordon d alimentation est endommag il doit tre imm diatement remplac par un cordon appropri disponible aupr s du fabricant ou de son prestataire de ser...

Page 3: ...appliance is intended to be used in household and similar applications such as staff kitchen areas in shops offices and other working environments farm houses and by clients in hotels motels and othe...

Page 4: ...D bit Eau Gazeuse L min Sparkling water flow seulement sur la version gazeuse only on sparkling version 3 Alimentation V Hz Power supply 230V 50Hz Poids net kg Net weight non gazeux gazeux 29 37 Charg...

Page 5: ...3 L min or 1 liter in 20 seconds Pression d eau 3 Bars Water pressure 3 Bars Pression CO2 5 Bars CO2 Pressure 5 Bars Entr e d eau Water inlet CO2 CO2 Eau froide Cold water Eau ambiante Ambient water E...

Page 6: ...ge d brancher le refroidisseur La qualit de la gaz ification d pend de la temp rature de l eau Au moment de l installation il est n cessaire d attendre que le refroidisseur ait refroidi l eau et form...

Page 7: ...d only be carried out by qualified technicians Before each maintenance or cleaning operation disconnect the cooler The quality of the gasification depends on the temperature of the water At the time o...

Page 8: ...sur la cuve de r frig ration 9 Connecter les tuyaux d arriv e d eau de CO2 pour les G80 EF ET EG et les sorties votre quipement 10 Ouvrir l arriv e d eau 11 Faire couler de l eau par les moyens de di...

Page 9: ...page 9 Figure 2 Figure 1 Figure 5 Figure 6 Figure 4 Figure 3...

Page 10: ...vided fig 9 15 Turn the adjusting screw until the needle on the manometer reaches 5 bar fig 10 16 Check that there are no leaks and that all connections and adjustments are correct 17 Connect the main...

Page 11: ...page 11 Figure 7 Figure 11 Figure 12 Figure 8 Figure 10 Figure 9...

Page 12: ...d sinfectant 1 Change the filter after 5000 liters or every 6 months fig 13 2 Before installing the filter and after each filter replacement you need to rinse it fig 14 Connect the filter input and do...

Page 13: ...page 13 Figure 17 Figure 13 Figure 14 Figure 16 Figure 15...

Page 14: ...ra R gler la position des tuyaux La pression de l eau est trop faible en entr e et la pompe fait Faire augmenter la pression d eau L eau froide sort doucement Le filtre eau bouch V rifier remplacer L...

Page 15: ...use vibrations Adjust the position of the pipes The pressure of water is too low and pump makes noise Increase the water pressure Cold water comes out gently The water filter is blocked Check replace...

Page 16: ...PRESSEUR COMPRESSOR RELAY 17 5727008 RACCORD 6x8 FITTING 6x8 TAIL 6 5216009 CONDENSATEUR DE DEMARRAGE STARTING CAPACITOR 18 5727085 RACCORD SONDE PROBE CONNECTOR 7 5210107 COMPRESSEUR COMPRESSOR 19 57...

Page 17: ...page 17 SCHEMA ELECTRIQUE ELECTRICAL DRAWING NOTES...

Page 18: ...page 18 IMPLANTATION...

Page 19: ...fontaines Connect you to Mistral reseller area and find all technical informations about coolers http www mistralcoolers com fr portail distributeur Retrouvez toute l actualit de Mistral sur All news...

Page 20: ...e l Epine 2 avenue Ambroise Croizat 91130 Ris Orangis FRANCE tel 33 0 1 60 79 37 61 fax 33 0 1 60 79 18 26 www mistralcoolers com Mistral Constructeur Toute reproduction est interdite Document non con...

Reviews: