Appendix D
Manual Operations
•
STOP
- Pressing Red MENU/STOP button will immediately stop
any current operation of the unit, but will not change the System
Mode from AUTO to OFF. (To change the System Mode to
OFF, use the Green
►
Auto/On/OFF button to cycle through
each of four System Modes. The
▲
at the top of the display
points to the active System Mode.
•
MANUAL MIST
- Pressing the
▲
and
▼
arrows simultaneously
(2 seconds) will activate a mist cycle for the duration
programmed in the SET-UP menu.
•
INSPECT
- Unit will mist for 5 minutes or until stopped.
Navigate to INS in the MAINTENANCE Menu. Press the Green
►
button for 5 seconds.
There are a number of operations that can be performed while
standing at the unit:
AGT
Unit is agitating contents of drum.
EMP
Empty. Unit has calculated zero remaining volume in tank.
HOLD
Anti-siphon or agitation valve is being held open at end of
mist cycle to allow pressure in nozzle circuit to decay and
close nozzles quickly.
INS
Unit is in Inspection Mode and will mist for 5 minutes or until
stopped.
MST
Unit is misting.
NOZ00
Unit stopped operating because the number of nozzles is set
to 0. Clear by pressing Red STOP button for 5 seconds.
ERR2**
No fluid pumped out of tank when tank level calculated as
above Empty. Potential problems: pump intake or nozzle
circuit clog, pump or motor failure. Clear by pressing Red
STOP button for 5 seconds..
ERR3**
Probable leak in nozzle circuit. Volume of fluid pumped out
of tank during previous mist was greater than expected.
Clear by pressing Red STOP button for 5 seconds.
SKIP
Unit will skip next programmed mist, having received signal
from remote transmitter to SKIP NEXT MIST. Clear by
holding down the
▲
arrow button for 3 seconds.
SUS
Wind sensor reading higher than user-set max and is
suspending programmed mist.
The previous mist was skipped because SKIP NEXT MIST
was triggered by the remote or the wind sensor blocked an
Auto Mist.
** Visible only on units equipped with optional leak detection
capability. Refer to Section 7 of this manual for more information.
Appendix C
Operating Displays
Controller Displays