10
Ductless recirculation is intended for applications where an exhaust duct work is not possible to be installed.
When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust
IURPFRRNLQJDUHGUDZQDQG¿OWHUHGE\DVHWRIRSWLRQDOFKDUFRDO¿OWHUV7KHDLULVWKHQSXUL¿HGDQGUH
circulated back within the home.
We recommend to ALWAYS exhaust air outside of the home by employing existing or installing new duct
ZRUNLISRVVLEOH7KHKRRGLVPRVWHIIHFWLYHDQGHI¿FLHQWDVDQH[KDXVWKRRG2QO\ZKHQWKHH[KDXVWRSWLRQ
is not possible should you recourse to converting the hood into a recirculating hood.
:KHQFRQYHUWHGWREHDUHFLUFXODWLQJKRRGDVHWRIFKDUFRDO¿OWHUVDUHUHTXLUHGRQWRSRILWVVWDQGDUG
Aluminum Mesh Filter set. Order according to its part number below. The standard Aluminum Mesh Filters are
LQWHQGHGWRFDSWXUHUHVLGXHIURPFRRNLQJDQGWKHRSWLRQDOFKDUFRDO¿OWHUVKHOSWRSXULI\IXPHVH[KDXVWHGIURP
cooking for re-circulation.
RECIRCULATING KIT (REQUIRED IF NO DUCTING IS USED)
.LWLQFOXGHVFKDUFRDO¿OWHUVFKDUFRDO¿OWHUEUDFNHWVDQGDLUGLYHUWHUSODWH
Hood Models
Part No.
Filters & Brackets in pkg.
MH008
RHRK008S
2
1. Purchase recirculating kit per the part number above
6HFXUHDLUGLYHUWHUSODWHWRZDOOEHORZGXFWFRYHUEUDFNHW),*&5XQ
6” ducting from top of hood and secure to air diverter plate.
5HPRYHDOXPLQXPPHVK¿OWHUVIURPKRRG,QVWDOOFKDUFRDO¿OWHU
EUDFNHWVLQVLGH¿OWHURSHQLQJ1RWHVFUHZVWRVHFXUHFKDUFRDO¿OWHU
EUDFNHWVDUHDOUHDG\SUHLQVWDOOHGLQWKHKRRGDQGPXVW¿UVWEH
UHPRYHG&OLSFKDUFRDO¿OWHUVRQWRFKDUFRDO¿OWHUEUDFNHWV),*&
5H,QVWDOODOXPLQXPPHVK¿OWHUV
For more details refer to manual
included with recirculating kit.
&KDUFRDO¿OWHUVPXVWEHUHSODFHGDIWHUHYHU\KRXUVRIXVHRU
approximately every 3 to 4 months based on an average of 1 - 2 hrs. of
GDLO\FRRNLQJWLPH
Charcoal Filter Replacements
Hood Model
Part No.
Qty to Order
MH008
RHCF001
2
'2127:$6+&+$5&2$/),/7(56&KDUFRDO¿OWHUVPD\QHHG
to be changed more often depending on cooking habits.
Installation –
Ductless Recirculating
FIG. C
Summary of Contents for MH00830AS