154VZ1 : 190111
28 / 33
E65
General ETCS system command fault detected by MIREL STB – channel M
§
ETCS system requests DA mode for more than one STM module
§
ETCS system request FA mode for all STM modules
E70
General fault of MIREL STB gateway – channel C
§
faults detected by WD-type watchdog circuits
§
FLASH, EEPROM, RAM memory faults
§
faults in decoding and processor execution of instructions
E71
Integrity fault involving the requested working regime of the MIREL STB gateway
– channel C and the actual MIREL VZ1 working regime
E72
Integrity fault involving the requested working regime between MIREL STB
channels M and C detected by channel C
E73
General communication fault of MIREL STB gateway – channel C
§
communication fault between MIREL STB and MIREL VZ1
§
communication fault between channels M and C
E74
Communication fault between MIREL STB – channel C with the ETCS system
E75
General ETCS system command fault detected by MIREL STB – channel C
§
ETCS system requests DA mode for more than one STM module
§
ETCS system request FA mode for all STM modules
E80
Communication fault with MIREL STB – channel M detected by the MIREL VZ1
system
E81
Communication fault with MIREL STB – channel C detected by the MIREL VZ1
system
E82
Integrity fault involving the digital inputs used to control stand-by regime
E83
General fault of the recording equipment
E84
Integrity fault involving the interface with the SHP system
E85
Error of communication with MIREL SHPE generator – M-channel, detected by
MIREL VZ1 system
E86
Error of communication with MIREL SHPE generator – C-channel, detected by
MIREL VZ1 system
E90
Combined error of MIREL SHPE generator – channel M
§
Errors detected by watchdog circuits
§
Errors of decoding and of processor instruction execution
§
Errors of internal communication with peripherals circuits
§
Errors of FLASH, EEPROM, RAM memories
Power supply errors
E91
Integrity error between M and C channels of MIREL SHPE generator – M-
channel
E92
Error of communication of MIREL SHPE generator – M-channel
E93
Antenna error of MIREL SHPE generator – M-channel
E95
Combined error of MIREL SHPE generator – channel C
extent of combined error identical like with
E90
E96
Integrity error between M and C channels of MIREL SHPE generator - C-channel
E97
Communication error of MIREL SHPE generator – C-channel
E98
Antenna error of MIREL SHPE generator – C-channel
The EPV does not open and the emergency brake does not activate in the event of a fault
that restricts subsequent use of the system. No fault is indicated on the front panel of the
central unit or on the signal repeater. In this case, the fault involves the signal repeater in the
inactive cab. These faults only restrict the operation of the train protection system to the cab
in which the signal repeater that is operating normally is installed.
All faults detected during operations in ZAV working regime while in motion are classified as
faults restricting subsequent use of the system. These faults are then reclassified depending
Summary of Contents for VZ1