8

2.2   Rear Panel

2.2.1   Quartet

The Quartet rear panel is composed of an AC receptacle, a fan assembly, a DC
power connector for power redundancy, and 32 BNC connectors. The BNC
connectors are combined to form groups of 8. Each group belongs to one of the
housing frame's internal modules. Refer to Figure 2.2 for module and BNC
referencing.

                                                                                                  

Figure 2.2

   Quartet rear panel

AC power connector

Fan assembly

DC power
connector

Module #1 connectors

Module #2 connectors

Module #4 connectors

Module #3 connectors

                                                                                                  

2.2.2   Quartet-C

The Quartet-C rear panel is very much similar to that of Quartet's. It is composed of
an AC receptacle, a fan assembly, an ICP-S (RS-422) interface port with loop-
through, a rotary switch required for ICP-S serial ID assignments in a daisy chain
installation, and 32 BNC connectors. The BNC connectors are combined to form
groups of 8. Each group belongs to one of the housing frame's internal modules.
Refer to Figure 2.3 for module and BNC referencing.

                                                                                                  

Figure 2.3

   Quartet-C rear panel

Module #1 connectors

Module #2 connectors

Module #4 connectors

Module #3 connectors

RS-422 interface port
with loop-through

RS-422

RS-422 serial ID assignment

rotary switch

AC power connector

Fan assembly

                                                                                                  

Summary of Contents for Quartet

Page 1: ...rtet imaging HousingFrame Guide to Installation and Operation M028 9900 300 Copyright 1999 MirandaTechnologies Inc Specifications may be subject to change Printed in Canada June 1999 Quartet imaging Series ...

Page 2: ...y within 36 hours of factory notification If the equipment to be repaired is essential and the customer so requests Miranda will at its option provide a service replacement or loaner part or product usually within 36 hours of factory notification weekends and holidays excluded All warranty exchange or loaner parts or products shall be shipped to the Buyer with a packing list clearly describing the...

Page 3: ... CSA C22 2 No 1 94 Standard for audio video and similar electronic equipment UL No 1419 Standard for professional video and audio equipment An appropriately listed mains supply power cord with following characteristics must be used for the connection of the equipment Listed 3 pin grounding type 18 3 AWG type SVT or SJT EN60065 1993 EN60065 1 1985 A2 1989 A3 1992 Part 1 European Standard Safety req...

Page 4: ...stallation 13 3 2 DC Power Redundancy 13 3 3 Power Supply Removal and Installation 14 3 4 RS 422 Serial Connection 16 3 5 RS 422 Serial ID Assignment 17 3 6 RS 422 Cable Construction 19 3 7 Installing an imaging Series Module 20 3 8 Removing an imaging Series Module 20 3 9 Rear Panel Label 21 3 10 Air Filter Removal and Cleaning 22 3 11 imaging Extender Module 23 4 Power Supply 25 4 1 Powering Up ...

Page 5: ...4 ...

Page 6: ...fer to section 3 2 DC Power Redundancy for more details Some Quartet housing frames are equipped with an RS 422 serial interface providing remote configuration of imaging modules using Miranda s ICP S application An RS 422 loop through allows Quartet housing frames to be daisy chained together and controlled by a host computer Audio modules can now be installed in Quartet housing frame supporting ...

Page 7: ... ü ü Quartet A 110 ü ü ü ü ü ü Quartet M A 75 ü ü ü ü ü Quartet M A 110 ü ü ü ü ü ü In this table and in section 2 2 1 the name Quartet designates a basic frame Frames with more features are designated by their suffixes such as C M etc In this manual the term Quartet generally refers to all models when installation power supply module installation and similar subjects are concerned ...

Page 8: ...crews counter clockwise and pull on the handles Referring to Figure 2 1 Quartet houses up to 4 imaging series modules and a power supply Each module includes a module ejector for easy module removal For proper cooling do not leave the front panel removed for a long period of time when power is on Figure 2 1 imaging Quartet front panel Front Panel Exterior Handle Thumb screw Mounting hole Air vents...

Page 9: ...s 2 2 2 Quartet C The Quartet C rear panel is very much similar to that of Quartet s It is composed of an AC receptacle a fan assembly an ICP S RS 422 interface port with loop through a rotary switch required for ICP S serial ID assignments in a daisy chain installation and 32 BNC connectors The BNC connectors are combined to form groups of 8 Each group belongs to one of the housing frame s intern...

Page 10: ...nterface port with loop through and 4 groups of 5 BNC 1 HD 15 1 RJ 45 connectors Each group belongs to one of the housing frame s internal modules Refer to Figure 2 5 for module and BNC referencing For a pin out of the RJ 45 and HD 15 connectors refer to the module s user manual Figure 2 5 Quartet A 75 rear panel Module 1 connectors Module 2 connectors Module 4 connectors Module 3 connectors AC po...

Page 11: ...th loop through 2 groups of 5 BNC 1 HD 15 1 RJ 45 connectors as in the Quartet A 75 and 2 groups of 7 BNC 1 RJ 45 connectors as in the Quartet M Each group belongs to one of the housing frame s internal modules Refer to Figure 2 7 for module and BNC referencing For a pin out of the RJ 45 and HD 15 connectors refer to the module s user manual Figure 2 7 Quartet M A 75 rear panel Module 1 connectors...

Page 12: ...tors as in the Quartet M Each group belongs to one of the housing frame s internal modules Refer to Figure 2 8 for module and BNC referencing For a pin out of the RJ 45 HD 15 and HD 26 connectors refer to the module s user manual Figure 2 8 Quartet M A 110 rear panel Module 1 connectors Module 2 connectors Module 4 connectors Module 3 connectors AC power connector Fan assembly DC power connector R...

Page 13: ...12 ...

Page 14: ...not surpass the current capacity of one power supply To find out how much current is required for the installed modules refer to the Specifications section of the module s Guide to Installation and Operation If the total consumption surpasses the current capacity a dedicated redundant power supply may be installed in a Quartet RPS frame which may hold up to three power suplies for redundancy purpo...

Page 15: ...of a Quartet frame Figure 3 2 DC cable construction Terminal strip top view Terminal strip top view 18 AWG Figure 3 3 DC connector pinout 8V 6V GND GND 15V 15V External DC connector Quartet and Quartet RPS rear panels 3 3 Power Supply Removal and Installation Follow these steps in order to remove the Quartet power supply 1 Remove the front panel by rotating the thumb screws counter clockwise Pull ...

Page 16: ...tall a power supply within a Quartet housing frame 1 Remove the front panel by rotating the thumb screws counter clockwise Pull on the handles 2 Insert the power supply in its assigned slot and gently push the power supply towards the rear of the housing frame Firmly push the power supply in order to attach it to the back plane 3 Using a flat edge screwdriver secure the power supply to the housing...

Page 17: ...serial identification assignment required for the housing frame Refer to section 3 5 RS 422 Serial ID Assignment Multi Quartet Installation 1 Connect the RS 422 cable of Figure 3 7 between the PC RS 422 converter and one of the RS 422 ports situated on the first housing frame in the daisy chain 2 Connect the Windows NT workstation and the PC RS 422 converter with a proper cable Refer to the conver...

Page 18: ...switch on Quartet C s rear panel Refer to Figure 3 5 2 Using a small flat edge screwdriver identify each housing frame by setting a unique address to each The available addresses are 0 1 2 3 4 5 6 7 8 9 A B C D E and F producing a total of 16 ID assignments Two Quartet housing frames cannot have the same address However a Quartet housing frame a Symphonie housing frame and a Solo housing frame can...

Page 19: ...each The available addresses are 0 1 2 3 4 5 6 7 8 9 A B C D E and F producing a total of 16 ID assignments Two Quartet housing frames cannot have the same address However a Quartet frame a Symphonie housing frame and a Solo frame can have the same address 4 Reinstall the power supply To do so refer to section 3 3 Power Supply Removal and Installation 5 Configure the workstation software to reflec...

Page 20: ... mini DIN8 connectors Use Figure 3 9 to construct a cable for connection between Quartet and Symphonie housing frames Figure 3 7 Cable between Quartet C and PC RS 422 converter Figure 3 8 Cable between Quartet C Solo housing frames Male Mini DIN8 viewed from back Male Mini DIN8 viewed from front 8 7 6 5 4 3 2 1 0 Figure 3 9 Cable between Quartet C Solo and Symphonie housing frames Male Mini DIN8 v...

Page 21: ...eplace the front panel Make sure to rotate the thumb screws clockwise in order to secure the front panel to the chassis Figure 3 10 Module guide location Module guides 1 0 Place module here Place module here 3 8 Removing an imaging Series Module It is not necessary to switch off the power when removing a module from a housing frame To remove a module follow these steps 1 Remove the front panel by ...

Page 22: ...he label follow these steps 1 On the housing frame s rear panel locate the appropriate connectors for the front slot where the imaging module has been installed as specified in section 3 7 2 Remove the screws as shown in Figure 3 11 3 Carefully apply the label to the connectors 4 Replace the screws making sure not to damage the label Figure 3 11 Rear panel label installation imaging Quartet top vi...

Page 23: ...s 2 Carefully remove the lexan membrane and the air filter behind the front panel 3 Use running water to clean the air filter Make sure to dry off the air filter before attempting to replace it back into its original location 4 When replacing the air filter make sure to tuck it back into place behind the metal rails Reinstall the lexan membrane to block 2 3 of the air filter as shown on figure 3 1...

Page 24: ...he Figure 3 13 To remove the module under test simply push on the ejectors situated at the front of the extender module and pull out the module under test To remove the extender module carefully pull on it in order to detach it from the housing frame s rear motherboard For complete instructions on module installation and module removal refer to sections 3 7 and 3 8 respectively Figure 3 13 imaging...

Page 25: ...24 ...

Page 26: ... at least one power supply voltage level has failed This may also occur after a thermal shutdown by the power supply A thermal shutdown occurs at a temperature of 70 C 158 F setting all output voltage levels to 0 The power supply will restart only when its temperature has dropped to at least 50 C 122 F O L This LED lights up to indicate a current overload has been detected on one of the DC power l...

Page 27: ... is viewed from the back where the actual wire connections are to be made The mini Din 8 rear panel connector provides a normally closed contact and a normally open contact During normal operation there is a closed contact between pins 1 and 7 and an open contact between pins 2 and 7 If the power supply fails or experiences a current overload contact between pins 1 and 7 opens and contact between ...

Page 28: ...20 HD 15 4 RJ 45 4 DC power Terminal strip 6 8V 6V GND GND 15V 15V Serial port RS 422 on mini DIN 8 2 Power failure alarm NC contacts on mini Din 8 2 Quartet A 110 I O connectors 75 ohm BNC 8 HD 15 4 HD 26 4 RJ 45 4 DC power Terminal strip 6 8V 6V GND GND 15V 15V Serial port RS 422 on mini DIN 8 2 Power failure alarm NC contacts on mini Din 8 2 Quartet M A 75 I O connectors 75 ohm BNC 24 HD 15 2 R...

Page 29: ... contacts on mini Din 8 2 All Quartets Power input 100 264 VAC 50 60 Hz 225 W Maximum DC power capacity 130 W 5V 10 A 8V 5A 15V 1A Re section 3 2 when calculating total module load it should never exceed 80 of the maximum value specified Dimensions 1 RU x 327 mm deep 12 9 Weight 3 6 Kg 7 9 lbs Temperature 0 C to 40 C ...