NV8256-Plus Digital Video Router • User’s Guide
27
3. Installation
Making Power Connections
isolated alarm signals that can be connected to an external alarm indicator. For information on con-
necting NV6257 alarms connections, see
on page 46.
Power Cords and Branch Circuits
For added protection in the event of a mains power failure, it is recommended that each power cord
connected to the NV6257 power supply be connected to a separate branch circuit. A wire bail can
be used to hold the power cable in place to reduce the possibility of an accidental disconnect.
The power cords are the only means of disconnecting AC power. Clearly mark the line side power
connection with its function so that in the event of an emergency, power can be disconnected
quickly.
Connecting Power to the NV6257 and the Router
The NV8256-Plus uses both power connections on the NV6257. To make this connection, Miranda
provides two power cables (WC0085-00).
How to Connect Power:
1 Locate the power cords, PS6000 power supply modules, and cables supplied by Miranda.
2 If not already removed, remove all PS6000 power supply modules.
3 Facing the rear of the
NV6257
, using one of the two power supply cables (WC0085-00), con-
nect to ‘Output Power 1’, as shown in Figure 3-1.
Caution
Make power connections between the router and NV6257
before
connecting the
NV6257 to an AC power source. Insert PS6000 power supply modules
after
con-
necting the NV6257 to an AC power source.
Connecting to AC power before the router is connected, or after PS6000 modules
are installed, may result in an electric shock.
Summary of Contents for NV8256-Plus
Page 10: ...x Rev 1 3 29 Mar 09 Table of Contents ...
Page 60: ...50 Rev 1 3 29 Mar 09 3 Installation Verification ...
Page 66: ...56 Rev 1 3 29 Mar 09 5 Configuration UniConfig ...
Page 72: ...62 Rev 1 3 29 Mar 09 6 Maintenance Obtaining Service ...
Page 82: ...72 Rev 1 3 29 Mar 09 9 Part Numbers Frame Expansion ...
Page 88: ...78 Rev 1 3 29 Mar 09 Index ...