GUIDE TO INSTALLATION AND OPERATION 
 

12

  |  DDA-1113 

Mode AUTO 
A START will initiate an automatic sequence, indicated by PROCESS. When the input status becomes correct it will 
stop and SUCCESS will be displayed. FAIL will be displayed to indicate that no correction has been found that will 
yield a correct input status 
 

Input Load 

The

 Hi-Z 

selection is to be used along with a rear panel DDA-1113-DRP/L only to insure that the input signal is loaded 

only once at the end of the chain.  

3.3.3  Alarms Tab 

 

 

 

 

 

 

 

 

 

 

 

 

 

Selecting the Alarm config button opens a separate window for error status reporting. The alarm Configuration Panel 
shows a listing of the alarms reported by the card. 

The Card LED, Overall alarm and GSM contribution columns contain pull-down lists that allow the level of contribution 
of each individual alarm to the alarm named in the column heading to be set. 

Card LED 

This column allows configuration of the contribution of selected individual alarms to the status LED located on the 
front card edge. The Card LED status is shown at the bottom of the alarm tree in the Status/Name column. 

Overall Alarm 

This column allows configuration of the contribution of each individual alarm to the Overall Alarm associated with this 
card. The Overall Status is reflected by the color of the indicator attached to the card in iControl Navigator. It is also 
displayed in the upper left corner of the iControl Interface of the DDA-1113. 

GSM Contribution 

This column allows configuration of the contribution of each individual alarm to the GSM Alarm Status associated with 
this card. GSM is a dynamic register of all iControl system alarms, and is also an alarm provider for external 
applications. The possible values for this contribution are related to the Overall alarm contribution: 

• 

If the Overall alarm contribution is set to Disabled, the GSM alarm contribution can be set to any available value 

• 

If the Overall alarm contribution is selected as any level other than disabled, the GSM contribution is forced to 
follow the Overall Alarm. 

 

 

 

Figure 3.4 

Alarms Tab 

Summary of Contents for Densite series DDA-1113

Page 1: ......

Page 2: ...quipment has been tested and found to comply with the requirements of the EMC directive 2004 108 CE EN 55022 Class A radiated and conducted emissions EN 55024 Immunity of Information Technology Equipm...

Page 3: ...6 2 Installation 7 2 1 Unpacking 7 2 2 Installation in the Densit frame 7 2 3 Rear Connector Panel 7 3 Operation 8 3 1 Card Edge Controls and Indicators Status Led 8 3 2 Local control using the Densi...

Page 4: ...GUIDE TO INSTALLATION AND OPERATION DDA 1113...

Page 5: ...he content of the audio signal A multi colored LED visible with the door closed reports the card status The DDA 1113 requires a single or a double rear connector panel 1 2 Features Digital audio distr...

Page 6: ...terface The front card edge of the DDA 1113 incorporates two elements Status LED see section 3 1 Select Button see section 3 2 Figure 1 2 Card edge controls and indicators SDA 1101 SD DIGITAL VIDEO DI...

Page 7: ...st be mounted in a DENSIT 2 or DENSIT 3 frame It is not necessary to switch off the frame s power when installing or removing the card See the DENSIT Frame manual for detailed instructions for install...

Page 8: ...dition cannot cause the LED to assume that status If more than one LED status is possible for a particular error condition the status is configurable See Section 3 2 2 for details The factory default...

Page 9: ...pushbuttons located beneath the display The functionality of the pushbuttons is as follows Used for menu navigation and value modification SELECT Gives access to the next menu level When a parameter v...

Page 10: ...to a correct input status LENGTH This command allows a manual adjustment of the correction applied to the input signal The input status is displayed at the same time to ease the setting o Set the inpu...

Page 11: ...t of factory selected values that can be used to return your DDA 1113 to a standard operating condition The default values are shown as underlined in the DDA 1113 Menu on page 10 3 3 1 Status Tab This...

Page 12: ...f selected individual alarms to the status LED located on the front card edge The Card LED status is shown at the bottom of the alarm tree in the Status Name column Overall Alarm This column allows co...

Page 13: ...of alarm events for each individual alarm At the bottom of the window are several other controls Overall alarm and GSM contribution follow card LED Click in the checkbox to force the Overall alarm and...

Page 14: ...A 1113 The boxes titled Label Short Label Source ID and Comments are editable the user can enter their own information The Advanced button displays the name of the server within the iControl system th...

Page 15: ...tputs Signal AES3 id SMPTE 276M Level 1 Vpp Impedance 75 unbalanced Rise fall time 36 32 ns Overshoot 0 Return loss 15 dB 6 144MHz Jitter reduction 6 dB 20 kHz Specific jitter 0 005 UI pp 700 Hz to 10...

Reviews: