background image

* NOTE: The deck space of MIRGA6042, MIRGA7242 and MIRWH7140 have only the width of the deck given, since 

there is no deck space available in the corners as it is depicted in the graphic above.

Additional Note: On the MIRED6032, MIRED6036, MIRED6636, MIRED7232, MIRED7236, inside corners are square.

NOTE: There is no deck space on the MIRB6640 & MIRB7242 models.

Illustration J

Faucet Deck Mount

Dimensions

Deck space where faucets can be mounted is given in a
diagonal dimension Y and a base line dimension Z, which
is the long side of the deck corner.

“L”

LENGTH

“W” 

WIDTH

“Y”

DIAGONAL

DECK

DIM

“Z” 

BASE LINE

DECK

DIM

DROP-IN MODEL 

SEE ILLUSTRATION J 

MIRBDA6032, MIRBDS6032, MIRBDT6032, MIRBDW6032 

60" 

32" 

6-1/2" 

14" 

MIRBRA6640V, MIRBRS6640V, MIRBRT6640V, MIRBRW6640V 

66" 

40" 

N/A

N/A

MIRBRA7242V, MIRBRS7242V, MIRBRT7242V, MIRBRS7242V

71-1/2" 

42" 

N/A

N/A

MIREDA6032, MIREDS6032, MIREDT6032, MIREDT6032 

59-3/4" 

31-7/8" 

2-3/4" 

8"  

MIREDA6036, MIREDS6036, MIREDT6036, MIREDW6036 

59-3/4" 

35-3/4" 

3-1/4" 

10-3/4" 

MIREDA6636, MIREDS6636, MIREDT6636, MIREDW6636

66" 

36"

3"*

11"* 

MIREDA7236, MIREDS7236, MIREDT7236, MIREDW7236 

71-1/2" 

35-3/4" 

3" 

10-3/4" 

MIRGAA6042, MIRGAS6042, MIRGAT6042, MIRGAW6042

60" 

42" 

3"* 

3"*  

MIRGAA7242, MIRGAS7242, MIRGAT7242, MIRGAW7242

72" 

42" 

3"* 

3"*  

MIRKWA6036, MIRKWS6036, MIRKWT6036, MIRKWW6036 

60" 

36" 

6-1/2" 

14" 

MIRKWA7236, MIRKWS7236, MIRKWT7236, MIRKWW7236

72" 

36" 

6-1/2" 

14"   

MIRPRA6032, MIRPRS6032, MIRPRT6032, MIRPRW6032 

60" 

32" 

7-1/2" 

15-1/2"

MIRSAA6042, MIRSAS6042, MIRSAT6042, MIRSAW6042

60" 

42" 

7-1/2" 

15"

MIRSAA6060, MIRSAS6060, MIRSAT6060, MIRSAW6060

60" 

60" 

9" 

18"

MIRSAA7242, MIRSAS7242, MIRSAT7242, MIRSAW7242

72" 

42" 

7-1/2"  

15"

MIRWHA7140, MIRWHS7140, MIRWHT7140, MIRWHW7140

71-1/2" 

40" 

5"*  

5"*

7

INSTALLATION PLANNING AND PREPARATION

1. 

NEVER LIFT THE TUB BY THE PLUMBING. Doing so can result in leaks.

2. Check if the floor is level and of good quality. An uneven floor may impede 

proper installation of the product. The floor structure must be capable of 

supporting at least 100 pounds per square foot.

a. Clean the area of any debris or trash.

b. Use setting compound if the floor is level. If it is not, calculate how much 

you have to use to level the tub. 

c. Insure that you place the drain 

rough at the proper location.

d. Check if the installer placed the 

proper electrical service near the 

pump location. See electrical 

requirements for specifications.

3. If this is a deck installation, measure 

from the floor to the bottom of the 

rim to ensure that the tub is not 

suspended by its rim.

You should always have the entire tub floor fully supported 

with setting compound.

TYPICAL FLANGE MOUNTING DETAIL

1 x 4 (25 x 76mm) WOOD

STRINGER FULL LENGTH

TUB

STUD

WATERPROOF DRYWALL

OR CEMENT BOARD

TILE

SEALANT

ROOFING NAIL

SUGGESTED WHIRLPOOL/BATH

INSTALLATION METHOD

WOOD

STUDS

HEIGHT TO LIP

SETTING COMPOUND

* NOTE: The deck space of MIRGA6042, MIRGA7242 and MIRWH7140 have only the width of the deck given, since 

there is no deck space available in the corners as it is depicted in the graphic above.

Additional Note: On the MIRED6032, MIRED6036, MIRED6636, MIRED7232, MIRED7236, inside corners are square.

NOTE: There is no deck space on the MIRB6640 & MIRB7242 models.

Illustration J

Faucet Deck Mount

Dimensions

Deck space where faucets can be mounted is given in a
diagonal dimension Y and a base line dimension Z, which
is the long side of the deck corner.

“L”

LENGTH

“W” 

WIDTH

“Y”

DIAGONAL

DECK

DIM

“Z” 

BASE LINE

DECK

DIM

DROP-IN MODEL 

SEE ILLUSTRATION J 

MIRBDA6032, MIRBDS6032, MIRBDT6032, MIRBDW6032 

60" 

32" 

6-1/2" 

14" 

MIRBRA6640V, MIRBRS6640V, MIRBRT6640V, MIRBRW6640V 

66" 

40" 

N/A

N/A

MIRBRA7242V, MIRBRS7242V, MIRBRT7242V, MIRBRS7242V

71-1/2" 

42" 

N/A

N/A

MIREDA6032, MIREDS6032, MIREDT6032, MIREDT6032 

59-3/4" 

31-7/8" 

2-3/4" 

8"  

MIREDA6036, MIREDS6036, MIREDT6036, MIREDW6036 

59-3/4" 

35-3/4" 

3-1/4" 

10-3/4" 

MIREDA6636, MIREDS6636, MIREDT6636, MIREDW6636

66" 

36"

3"*

11"* 

MIREDA7236, MIREDS7236, MIREDT7236, MIREDW7236 

71-1/2" 

35-3/4" 

3" 

10-3/4" 

MIRGAA6042, MIRGAS6042, MIRGAT6042, MIRGAW6042

60" 

42" 

3"* 

3"*  

MIRGAA7242, MIRGAS7242, MIRGAT7242, MIRGAW7242

72" 

42" 

3"* 

3"*  

MIRKWA6036, MIRKWS6036, MIRKWT6036, MIRKWW6036 

60" 

36" 

6-1/2" 

14" 

MIRKWA7236, MIRKWS7236, MIRKWT7236, MIRKWW7236

72" 

36" 

6-1/2" 

14"   

MIRPRA6032, MIRPRS6032, MIRPRT6032, MIRPRW6032 

60" 

32" 

7-1/2" 

15-1/2"

MIRSAA6042, MIRSAS6042, MIRSAT6042, MIRSAW6042

60" 

42" 

7-1/2" 

15"

MIRSAA6060, MIRSAS6060, MIRSAT6060, MIRSAW6060

60" 

60" 

9" 

18"

MIRSAA7242, MIRSAS7242, MIRSAT7242, MIRSAW7242

72" 

42" 

7-1/2"  

15"

MIRWHA7140, MIRWHS7140, MIRWHT7140, MIRWHW7140

71-1/2" 

40" 

5"*  

5"*

7

INSTALLATION PLANNING AND PREPARATION

1. 

NEVER LIFT THE TUB BY THE PLUMBING. Doing so can result in leaks.

2. Check if the floor is level and of good quality. An uneven floor may impede 

proper installation of the product. The floor structure must be capable of 

supporting at least 100 pounds per square foot.

a. Clean the area of any debris or trash.

b. Use setting compound if the floor is level. If it is not, calculate how much 

you have to use to level the tub. 

c. Insure that you place the drain 

rough at the proper location.

d. Check if the installer placed the 

proper electrical service near the 

pump location. See electrical 

requirements for specifications.

3. If this is a deck installation, measure 

from the floor to the bottom of the 

rim to ensure that the tub is not 

suspended by its rim.

You should always have the entire tub floor fully supported 

with setting compound.

TYPICAL FLANGE MOUNTING DETAIL

1 x 4 (25 x 76mm) WOOD

STRINGER FULL LENGTH

TUB

STUD

WATERPROOF DRYWALL

OR CEMENT BOARD

TILE

SEALANT

ROOFING NAIL

SUGGESTED WHIRLPOOL/BATH

INSTALLATION METHOD

WOOD

STUDS

HEIGHT TO LIP

SETTING COMPOUND

* NOTE: The deck space of MIRGA6042, MIRGA7242 and MIRWH7140 have only the width of the deck given, since 

there is no deck space available in the corners as it is depicted in the graphic above.

Additional Note: On the MIRED6032, MIRED6036, MIRED6636, MIRED7232, MIRED7236, inside corners are square.

NOTE: There is no deck space on the MIRB6640 & MIRB7242 models.

Illustration J

Faucet Deck Mount

Dimensions

Deck space where faucets can be mounted is given in a
diagonal dimension Y and a base line dimension Z, which
is the long side of the deck corner.

“L”

LENGTH

“W” 

WIDTH

“Y”

DIAGONAL

DECK

DIM

“Z” 

BASE LINE

DECK

DIM

DROP-IN MODEL 

SEE ILLUSTRATION J 

MIRBDA6032, MIRBDS6032, MIRBDT6032, MIRBDW6032 

60" 

32" 

6-1/2" 

14" 

MIRBRA6640V, MIRBRS6640V, MIRBRT6640V, MIRBRW6640V 

66" 

40" 

N/A

N/A

MIRBRA7242V, MIRBRS7242V, MIRBRT7242V, MIRBRS7242V

71-1/2" 

42" 

N/A

N/A

MIREDA6032, MIREDS6032, MIREDT6032, MIREDT6032 

59-3/4" 

31-7/8" 

2-3/4" 

8"  

MIREDA6036, MIREDS6036, MIREDT6036, MIREDW6036 

59-3/4" 

35-3/4" 

3-1/4" 

10-3/4" 

MIREDA6636, MIREDS6636, MIREDT6636, MIREDW6636

66" 

36"

3"*

11"* 

MIREDA7236, MIREDS7236, MIREDT7236, MIREDW7236 

71-1/2" 

35-3/4" 

3" 

10-3/4" 

MIRGAA6042, MIRGAS6042, MIRGAT6042, MIRGAW6042

60" 

42" 

3"* 

3"*  

MIRGAA7242, MIRGAS7242, MIRGAT7242, MIRGAW7242

72" 

42" 

3"* 

3"*  

MIRKWA6036, MIRKWS6036, MIRKWT6036, MIRKWW6036 

60" 

36" 

6-1/2" 

14" 

MIRKWA7236, MIRKWS7236, MIRKWT7236, MIRKWW7236

72" 

36" 

6-1/2" 

14"   

MIRPRA6032, MIRPRS6032, MIRPRT6032, MIRPRW6032 

60" 

32" 

7-1/2" 

15-1/2"

MIRSAA6042, MIRSAS6042, MIRSAT6042, MIRSAW6042

60" 

42" 

7-1/2" 

15"

MIRSAA6060, MIRSAS6060, MIRSAT6060, MIRSAW6060

60" 

60" 

9" 

18"

MIRSAA7242, MIRSAS7242, MIRSAT7242, MIRSAW7242

72" 

42" 

7-1/2"  

15"

MIRWHA7140, MIRWHS7140, MIRWHT7140, MIRWHW7140

71-1/2" 

40" 

5"*  

5"*

7

INSTALLATION PLANNING AND PREPARATION

1. 

NEVER LIFT THE TUB BY THE PLUMBING. Doing so can result in leaks.

2. Check if the floor is level and of good quality. An uneven floor may impede 

proper installation of the product. The floor structure must be capable of 

supporting at least 100 pounds per square foot.

a. Clean the area of any debris or trash.

b. Use setting compound if the floor is level. If it is not, calculate how much 

you have to use to level the tub. 

c. Insure that you place the drain 

rough at the proper location.

d. Check if the installer placed the 

proper electrical service near the 

pump location. See electrical 

requirements for specifications.

3. If this is a deck installation, measure 

from the floor to the bottom of the 

rim to ensure that the tub is not 

suspended by its rim.

You should always have the entire tub floor fully supported 

with setting compound.

TYPICAL FLANGE MOUNTING DETAIL

1 x 4 (25 x 76mm) WOOD

STRINGER FULL LENGTH

TUB

STUD

WATERPROOF DRYWALL

OR CEMENT BOARD

TILE

SEALANT

ROOFING NAIL

SUGGESTED WHIRLPOOL/BATH

INSTALLATION METHOD

WOOD

STUDS

HEIGHT TO LIP

SETTING COMPOUND

* NOTE: The deck space of MIRGA6042, MIRGA7242 and MIRWH7140 have only the width of the deck given, since 

there is no deck space available in the corners as it is depicted in the graphic above.

Additional Note: On the MIRED6032, MIRED6036, MIRED6636, MIRED7232, MIRED7236, inside corners are square.

NOTE: There is no deck space on the MIRB6640 & MIRB7242 models.

Illustration J

Faucet Deck Mount

Dimensions

Deck space where faucets can be mounted is given in a
diagonal dimension Y and a base line dimension Z, which
is the long side of the deck corner.

“L”

LENGTH

“W” 

WIDTH

“Y”

DIAGONAL

DECK

DIM

“Z” 

BASE LINE

DECK

DIM

DROP-IN MODEL 

SEE ILLUSTRATION J 

MIRBDA6032, MIRBDS6032, MIRBDT6032, MIRBDW6032 

60" 

32" 

6-1/2" 

14" 

MIRBRA6640V, MIRBRS6640V, MIRBRT6640V, MIRBRW6640V 

66" 

40" 

N/A

N/A

MIRBRA7242V, MIRBRS7242V, MIRBRT7242V, MIRBRS7242V

71-1/2" 

42" 

N/A

N/A

MIREDA6032, MIREDS6032, MIREDT6032, MIREDT6032 

59-3/4" 

31-7/8" 

2-3/4" 

8"  

MIREDA6036, MIREDS6036, MIREDT6036, MIREDW6036 

59-3/4" 

35-3/4" 

3-1/4" 

10-3/4" 

MIREDA6636, MIREDS6636, MIREDT6636, MIREDW6636

66" 

36"

3"*

11"* 

MIREDA7236, MIREDS7236, MIREDT7236, MIREDW7236 

71-1/2" 

35-3/4" 

3" 

10-3/4" 

MIRGAA6042, MIRGAS6042, MIRGAT6042, MIRGAW6042

60" 

42" 

3"* 

3"*  

MIRGAA7242, MIRGAS7242, MIRGAT7242, MIRGAW7242

72" 

42" 

3"* 

3"*  

MIRKWA6036, MIRKWS6036, MIRKWT6036, MIRKWW6036 

60" 

36" 

6-1/2" 

14" 

MIRKWA7236, MIRKWS7236, MIRKWT7236, MIRKWW7236

72" 

36" 

6-1/2" 

14"   

MIRPRA6032, MIRPRS6032, MIRPRT6032, MIRPRW6032 

60" 

32" 

7-1/2" 

15-1/2"

MIRSAA6042, MIRSAS6042, MIRSAT6042, MIRSAW6042

60" 

42" 

7-1/2" 

15"

MIRSAA6060, MIRSAS6060, MIRSAT6060, MIRSAW6060

60" 

60" 

9" 

18"

MIRSAA7242, MIRSAS7242, MIRSAT7242, MIRSAW7242

72" 

42" 

7-1/2"  

15"

MIRWHA7140, MIRWHS7140, MIRWHT7140, MIRWHW7140

71-1/2" 

40" 

5"*  

5"*

7

INSTALLATION PLANNING AND PREPARATION

1. 

NEVER LIFT THE TUB BY THE PLUMBING. Doing so can result in leaks.

2. Check if the floor is level and of good quality. An uneven floor may impede 

proper installation of the product. The floor structure must be capable of 

supporting at least 100 pounds per square foot.

a. Clean the area of any debris or trash.

b. Use setting compound if the floor is level. If it is not, calculate how much 

you have to use to level the tub. 

c. Insure that you place the drain 

rough at the proper location.

d. Check if the installer placed the 

proper electrical service near the 

pump location. See electrical 

requirements for specifications.

3. If this is a deck installation, measure 

from the floor to the bottom of the 

rim to ensure that the tub is not 

suspended by its rim.

You should always have the entire tub floor fully supported 

with setting compound.

TYPICAL FLANGE MOUNTING DETAIL

1 x 4 (25 x 76mm) WOOD

STRINGER FULL LENGTH

TUB

STUD

WATERPROOF DRYWALL

OR CEMENT BOARD

TILE

SEALANT

ROOFING NAIL

SUGGESTED WHIRLPOOL/BATH

INSTALLATION METHOD

WOOD

STUDS

HEIGHT TO LIP

SETTING COMPOUND

INSTALLATION PLANNING AND PREPARATION

1. NEVER LIFT THE TUB BY THE PLUMBING. Doing so can result in leaks.
2. Check if the floor is level and of good quality. An uneven floor may impede proper installation of the 

product. The floor structure must be capable of supporting at least 100 pounds per square foot.

  a. Clean the area of any debris or trash.
  b. Use setting compound if the floor is level. If it is not, calculate how much 
      you have to use to level the tub.
  c. Insure that you place the drain rough at the proper location.
  d. Check if the installer placed the proper electrical service near the pump 
      location. See electrical requirements 
      for specifications.
3. If this is a deck installation, measure from 

the floor to the bottom of the rim to 
ensure that the tub is not suspended by 
its rim. 

You should always have the entire tub floor 

fully supported with setting compound.

Faucet Deck Mount

Dimensions

Deck space where faucets can be mounted is given in a
diagonal dimension Y and a base line dimension Z, which
is the long side of the deck corner.

*NOTE: The deck space of MIRGA6042, MIRGA7242 and MIRWH7140 have only the width of the deck given, since there 
is no deck space available in the corners as it is depicted in the graphic above. Additional Note: On the MIRED6032, 
MIRED6036, MIRED6636, MIRED7232, MIRED7236, inside corners are square. 
†NOTE: There is no deck space on the MIRB6640 & MIRB7242 models.

WHIRLPOOL CONTROL CENTER FEATURES

The whirlpool is controlled by a three button control.
1. The first button switches the water-pump on or off. The 

other features will not operate unless the pump is turned on.

2. The second button sets the power level of the pump. Holding 

the button depressed will cycle the pump power from low to 
high in a continuous cycle. When the desired level is reached, 
remove your finger quickly from the button to maintain that 
power setting.

3. The third button is a three step wave action button. Once 

activated, the jets expel water in a slow pulsating flow called 
wave action. There are 3 steps or positions for wave strength.
a. Position #1 operates the pump at a steady flow.
b. Position #2 operates the pump at a quick wave action.
c. Position #3 operates the pump at a slower wave action.

AIR BATH CONTROL CENTER FEATURES

The air bath is controlled by a three button control.
1. The first button switches the blower on or off. The other 

features will not operate unless the blower is turned on.

2. The second button sets the power level of the blower. Holding 

the button depressed will cycle the blower power from low to 
high in a continuous cycle. When the desired level is reached, 
remove your finger quickly from the button to maintain that 
power setting.

3. The third button is a three step wave action button. Once 

activated, the air holes expel air in a slow pulsating flow called 
wave action. There are 3 steps or positions for wave strength.

a. Position #1 operates the blower at a steady flow.
b. Position #2 operates the blower at a quick wave action.
c. Position #3 operates the blower at a slower wave action.

TOTAL MASSAGE BATHS

Total Massage units are a combination of whirlpool and air
massages. The top three controls on the “Therapy Control Center”
operate the whirlpool and the bottom three controls operate the air
system. The whirlpool and air massage systems may be used at
the same time if desired. The air bath control center is explained in
the section above.
The whirlpool is controlled by a three button control.
1. The first button switches the pump on or off. The other features 
will not operate unless the pump is turned on.
2. The second button sets the power level of the pump. Holding 

the button depressed will cycle the pump power from low to 
high in a continuous cycle. When the desired level is reached, 
remove your finger quickly from the button to maintain that 
power setting.

3. The third button is a three step wave action button:

a. Position #1 operates the pump at a steady flow.
b. Position #2 operates the pump at a quick wave action.
c. Position #3 operates the pump with a slower wave action.

10

Illustration K

Illustration N

Illustration M

Illustration L

JET OPERATION AND ADJUSTMENT

The jets can be easily adjusted by pointing the jet-nozzle in the desired direction. The 
strength of the water flow and air induction can be regulated through twisting the jet- nozzle. 
Twisting the nozzle clockwise will decrease the water flow and finally completely turn off the 
water flow of that particular jet. If the nozzle is twisted counter clockwise then the water flow 
will increase up to its maximum flow. Only a 1/4 turn or 90

o

turn is required from the OFF 

position to the fully OPEN position.

JET OPERATION AND ADJUSTMENT

The jets can be easily adjusted by pointing the jet-nozzle in the desired direction. The strength 
of the water flow and air induction can be regulated through twisting the jet- nozzle. Twisting 
the nozzle clockwise will decrease the water flow and finally completely turn off the water 
flow of that particular jet. If the nozzle is twisted counter clockwise then the water flow will 
increase up to its maximum flow. Only a 1/4 turn or 90° turn is required from the OFF position 
to the fully OPEN position.

WHIRLPOOL CONTROL CENTER FEATURES

The whirlpool is controlled by a three button control.
1.  The first button switches the water-pump on or off. The other 
 

features will not operate unless the pump is turned on.

2.  The second button sets the power level of the pump. Holding
 

the button depressed will cycle the pump power from low to

 

high in a continuous cycle. When the desired level is reached,

 

remove your finger quickly from the button to maintain that

 

power setting.

3.  The third button is a three step wave action button. Once
 

activated, the jets expel water in a slow pulsating flow called

 

wave action. There are 3 steps or positions for wave strength.

 

a. Position #1 operates the pump at a steady flow.

 

b. Position #2 operates the pump at a quick wave action.

 

c. Position #3 operates the pump at a slower wave action.

AIR BATH CONTROL CENTER FEATURES

The air bath is controlled by a three button control.
1.  The first button switches the blower on or off. The other
 

features will not operate unless the blower is turned on.

2.  The second button sets the power level of the blower. Holding
 

the button depressed will cycle the blower power from low to

 

high in a continuous cycle. When the desired level is reached,

 

remove your finger quickly from the button to maintain that

 

power setting.

3.  The third button is a three step wave action button. Once
 

activated, the air holes expel air in a slow pulsating flow called

 

wave action. There are 3 steps or positions for wave strength.

 

a. Position #1 operates the blower at a steady flow.

 

b. Position #2 operates the blower at a quick wave action.

 

c. Position #3 operates the blower at a slower wave action.

TOTAL MASSAGE BATHS

Total Massage units are a combination of whirlpool and air massages. 
The top three controls on the “Therapy Control Center” operate the 
whirlpool and the bottom three controls operate the air system. The 
whirlpool and air massage systems may be used at the same time 
if desired. The air bath control center is explained in the section 
above.
The whirlpool is controlled by a three button control.
1.  The first button switches the pump on or off. The other features 
 

will not operate unless the pump is turned on.

2.  The second button sets the power level of the pump. Holding
 

the button depressed will cycle the pump power from low to

 

high in a continuous cycle. When the desired level is reached,

 

remove your finger quickly from the button to maintain that

 

power setting.

3.  The third button is a three step wave action button:
 

a. Position #1 operates the pump at a steady flow.

 

b. Position #2 operates the pump at a quick wave action.

 

 

 

 

 

 

 

c. Position #3 operates the pump with a slower wave action.

WHIRLPOOL CONTROL CENTER FEATURES

The whirlpool is controlled by a three button control.
1. The first button switches the water-pump on or off. The 

other features will not operate unless the pump is turned on.

2. The second button sets the power level of the pump. Holding 

the button depressed will cycle the pump power from low to 
high in a continuous cycle. When the desired level is reached, 
remove your finger quickly from the button to maintain that 
power setting.

3. The third button is a three step wave action button. Once 

activated, the jets expel water in a slow pulsating flow called 
wave action. There are 3 steps or positions for wave strength.
a. Position #1 operates the pump at a steady flow.
b. Position #2 operates the pump at a quick wave action.
c. Position #3 operates the pump at a slower wave action.

AIR BATH CONTROL CENTER FEATURES

The air bath is controlled by a three button control.
1. The first button switches the blower on or off. The other 

features will not operate unless the blower is turned on.

2. The second button sets the power level of the blower. Holding 

the button depressed will cycle the blower power from low to 
high in a continuous cycle. When the desired level is reached, 
remove your finger quickly from the button to maintain that 
power setting.

3. The third button is a three step wave action button. Once 

activated, the air holes expel air in a slow pulsating flow called 
wave action. There are 3 steps or positions for wave strength.

a. Position #1 operates the blower at a steady flow.
b. Position #2 operates the blower at a quick wave action.
c. Position #3 operates the blower at a slower wave action.

TOTAL MASSAGE BATHS

Total Massage units are a combination of whirlpool and air
massages. The top three controls on the “Therapy Control Center”
operate the whirlpool and the bottom three controls operate the air
system. The whirlpool and air massage systems may be used at
the same time if desired. The air bath control center is explained in
the section above.
The whirlpool is controlled by a three button control.
1. The first button switches the pump on or off. The other features 
will not operate unless the pump is turned on.
2. The second button sets the power level of the pump. Holding 

the button depressed will cycle the pump power from low to 
high in a continuous cycle. When the desired level is reached, 
remove your finger quickly from the button to maintain that 
power setting.

3. The third button is a three step wave action button:

a. Position #1 operates the pump at a steady flow.
b. Position #2 operates the pump at a quick wave action.
c. Position #3 operates the pump with a slower wave action.

10

Illustration K

Illustration N

Illustration M

Illustration L

JET OPERATION AND ADJUSTMENT

The jets can be easily adjusted by pointing the jet-nozzle in the desired direction. The 
strength of the water flow and air induction can be regulated through twisting the jet- nozzle. 
Twisting the nozzle clockwise will decrease the water flow and finally completely turn off the 
water flow of that particular jet. If the nozzle is twisted counter clockwise then the water flow 
will increase up to its maximum flow. Only a 1/4 turn or 90

o

turn is required from the OFF 

position to the fully OPEN position.

WHIRLPOOL CONTROL CENTER FEATURES

The whirlpool is controlled by a three button control.
1. The first button switches the water-pump on or off. The 

other features will not operate unless the pump is turned on.

2. The second button sets the power level of the pump. Holding 

the button depressed will cycle the pump power from low to 
high in a continuous cycle. When the desired level is reached, 
remove your finger quickly from the button to maintain that 
power setting.

3. The third button is a three step wave action button. Once 

activated, the jets expel water in a slow pulsating flow called 
wave action. There are 3 steps or positions for wave strength.
a. Position #1 operates the pump at a steady flow.
b. Position #2 operates the pump at a quick wave action.
c. Position #3 operates the pump at a slower wave action.

AIR BATH CONTROL CENTER FEATURES

The air bath is controlled by a three button control.
1. The first button switches the blower on or off. The other 

features will not operate unless the blower is turned on.

2. The second button sets the power level of the blower. Holding 

the button depressed will cycle the blower power from low to 
high in a continuous cycle. When the desired level is reached, 
remove your finger quickly from the button to maintain that 
power setting.

3. The third button is a three step wave action button. Once 

activated, the air holes expel air in a slow pulsating flow called 
wave action. There are 3 steps or positions for wave strength.

a. Position #1 operates the blower at a steady flow.
b. Position #2 operates the blower at a quick wave action.
c. Position #3 operates the blower at a slower wave action.

TOTAL MASSAGE BATHS

Total Massage units are a combination of whirlpool and air
massages. The top three controls on the “Therapy Control Center”
operate the whirlpool and the bottom three controls operate the air
system. The whirlpool and air massage systems may be used at
the same time if desired. The air bath control center is explained in
the section above.
The whirlpool is controlled by a three button control.
1. The first button switches the pump on or off. The other features 
will not operate unless the pump is turned on.
2. The second button sets the power level of the pump. Holding 

the button depressed will cycle the pump power from low to 
high in a continuous cycle. When the desired level is reached, 
remove your finger quickly from the button to maintain that 
power setting.

3. The third button is a three step wave action button:

a. Position #1 operates the pump at a steady flow.
b. Position #2 operates the pump at a quick wave action.
c. Position #3 operates the pump with a slower wave action.

10

Illustration K

Illustration N

Illustration M

Illustration L

JET OPERATION AND ADJUSTMENT

The jets can be easily adjusted by pointing the jet-nozzle in the desired direction. The 
strength of the water flow and air induction can be regulated through twisting the jet- nozzle. 
Twisting the nozzle clockwise will decrease the water flow and finally completely turn off the 
water flow of that particular jet. If the nozzle is twisted counter clockwise then the water flow 
will increase up to its maximum flow. Only a 1/4 turn or 90

o

turn is required from the OFF 

position to the fully OPEN position.

WHIRLPOOL CONTROL CENTER FEATURES

The whirlpool is controlled by a three button control.
1. The first button switches the water-pump on or off. The 

other features will not operate unless the pump is turned on.

2. The second button sets the power level of the pump. Holding 

the button depressed will cycle the pump power from low to 
high in a continuous cycle. When the desired level is reached, 
remove your finger quickly from the button to maintain that 
power setting.

3. The third button is a three step wave action button. Once 

activated, the jets expel water in a slow pulsating flow called 
wave action. There are 3 steps or positions for wave strength.
a. Position #1 operates the pump at a steady flow.
b. Position #2 operates the pump at a quick wave action.
c. Position #3 operates the pump at a slower wave action.

AIR BATH CONTROL CENTER FEATURES

The air bath is controlled by a three button control.
1. The first button switches the blower on or off. The other 

features will not operate unless the blower is turned on.

2. The second button sets the power level of the blower. Holding 

the button depressed will cycle the blower power from low to 
high in a continuous cycle. When the desired level is reached, 
remove your finger quickly from the button to maintain that 
power setting.

3. The third button is a three step wave action button. Once 

activated, the air holes expel air in a slow pulsating flow called 
wave action. There are 3 steps or positions for wave strength.

a. Position #1 operates the blower at a steady flow.
b. Position #2 operates the blower at a quick wave action.
c. Position #3 operates the blower at a slower wave action.

TOTAL MASSAGE BATHS

Total Massage units are a combination of whirlpool and air
massages. The top three controls on the “Therapy Control Center”
operate the whirlpool and the bottom three controls operate the air
system. The whirlpool and air massage systems may be used at
the same time if desired. The air bath control center is explained in
the section above.
The whirlpool is controlled by a three button control.
1. The first button switches the pump on or off. The other features 
will not operate unless the pump is turned on.
2. The second button sets the power level of the pump. Holding 

the button depressed will cycle the pump power from low to 
high in a continuous cycle. When the desired level is reached, 
remove your finger quickly from the button to maintain that 
power setting.

3. The third button is a three step wave action button:

a. Position #1 operates the pump at a steady flow.
b. Position #2 operates the pump at a quick wave action.
c. Position #3 operates the pump with a slower wave action.

10

Illustration K

Illustration N

Illustration M

Illustration L

JET OPERATION AND ADJUSTMENT

The jets can be easily adjusted by pointing the jet-nozzle in the desired direction. The 
strength of the water flow and air induction can be regulated through twisting the jet- nozzle. 
Twisting the nozzle clockwise will decrease the water flow and finally completely turn off the 
water flow of that particular jet. If the nozzle is twisted counter clockwise then the water flow 
will increase up to its maximum flow. Only a 1/4 turn or 90

o

turn is required from the OFF 

position to the fully OPEN position.

Summary of Contents for Boca Raton MIRBRA6640V

Page 1: ... not to subsequent owners transferees or users other than the first purchaser This warranty does not extend to products previously utilized as display models This Warranty shall apply to products installed and used only for personal family or household purposes and which are installed and maintained in accordance with Mirabelle Whirlpool and Bathing Systems recommended installation and maintenance...

Page 2: ...an before using the bathtub Never drop or insert any object into any opening Use this unit only for its intended use as described in this manual Do not use any attachments not recommended by Mirabelle The unit must be connected only to a supply circuit that is properly protected by a ground fault circuit interrupter GFCI Such a GFCI should be provided by the installer and should be tested on a rou...

Page 3: ... should contact the stringer or pier but supports no weight Provisions must be made in all installations for an access opening for servicing the bath pump Unless an access opening of at least 12 x 24 305mm x 610mm is provided warranty service will not be performed It is strongly recommended that an additional opening be provided for access to drain components Each bath has a nominal length L width...

Page 4: ...t support weight Allow the mortar material to completely harden before applying weight to the rim or bottom of the bath Any finish material such as tile or wall board must be self supporting if it contacts the deck of the bath FIGURE 1 E C 16 406 4 mm 16 406 4 mm G CUTOUT C F CUTOUT AS DESIRED 20 508 mm 20 508 mm W D LEVELING STRINGERS ACCESS PANEL MUST BE LOCATED ON THE SAME SIDE AS THE MOTOR ALL...

Page 5: ...hs and Total Massage units require dedicated 20 amp 120 volt service 3 You must provide a receptacle with a 20 amp configuration 4 See local codes for proper wire size if not specified use 12 Copper only wire 5 Use of an optional heater requires its own dedicated 20 amp service 12 WHIRLPOOL TUB CUT OUTS WHIRPOOL AND TUB CUT OUTS 66 000 RECESS MOUNT LINE CUT ALONG LINE FOR RECESS MOUNT INSTALLATION...

Page 6: ...ce from the floor at the drain opening to the bottom of the straight edge was measured See illustration G The lip height is then subtracted to give a more consistent floor to lip height There may be height dimension variations of 1 4 from the stated dimension in the table which is a stan dard production tolerance THIS PRODUCT IS DESIGNED FOR RESIDENTIAL USE AND USE BY HEALTHY INDIVIDUALS Children ...

Page 7: ... three controls operate the air system The whirlpool and air massage systems may be used at the same time if desired The air bath control center is explained in the section above The whirlpool is controlled by a three button control 1 The first button switches the pump on or off The other features will not operate unless the pump is turned on 2 The second button sets the power level of the pump Ho...

Page 8: ...inished deck surface or support stringers It may be necessary to partially fill the tub with water to aid in properly setting the tub 6 Verify that the product is level by checking the tub deck surface 7 Place the fill spout and supply lines at your desired location If you are installing the spout and supply lines on the deck of the tub mark the location first select a properly sized hole saw and ...

Page 9: ...s concessionnaires subséquent ou tout autre utilisateur que le premier acheteur Cette garantie ne s étend pas aux produits déjà utilisés tel que les modèles de démonstration Cette garantie s applique aux produits installés et utilisés à des fins personnelles familiales ou de maison et qui sont installés et entretenus conformément aux procédures d installation et d entretien des systèmes de baignad...

Page 10: ...la baignoire Ne jamais laisser échapper ou insérer un objet dans n importe quelle ouverture Utilisez cette unité seulement tel que décrit dans ce manuel Ne pas utiliser de raccords qui ne sont pas recommandés par Mirabelle Cette unité doit être connectée à un seul circuit d alimentation protégé correctement par un disjoncteur de fuite à la terre DDFT Ce DDFT devrait être offert par l installateur ...

Page 11: ...ations pour créer une ouverture d accès à la pompe de la baignoire À moins qu une ouverture d accès de 12 x 24 305mm x 610mm soit offerte le service de la garantie ne sera pas effectué Il est fortement recommandé qu une ouverture supplémentaire soit offerte pour accéder aux composants du drain Chaque baignoire possède une taille nominale en longueur L largeur l et hauteur H en plus d une hauteur d...

Page 12: ...IDE AS THE MOTOR ALLOW OPEN FRAMING ON PUMP MOTOR END FOR SERVICE ACCESS PANELS NOT REQUIRED FOR BATH TUBS ACCESS PANEL MUST BE LOCATED ON THE SAME SIDE AS THE MOTOR ALLOW OPEN FRAMING ON PUMP MOTOR END FOR SERVICE TILE BEAD STRIP BATH SEALANT WATERPROOF SEALANT BATH MOUNTING SURFACE AS DESIRED LEVELING STRINGER 1 x 4 not for support TILE WALLBOARD NOTE Tile bead kit not included and must be purch...

Page 13: ...250 WHIRPOOL AND TUB CUT OUTS 60 000 RECESS MOUNT LINE CUT ALONG LINE FOR RECESS MOUNT INSTALLATION FLUSH MOUNT LINE CUT ALONG LINE FOR FLUSH MOUNT INSTALLATION 2 875 52 625 Mirabelle Cut Out Template Use for Edenton 6032 Scale 1 1 0 250 3 50 16 000 13 000 2 75 Drain Drain Drain CIRCUIT TOTAL MASSAGE AVEC RÉCHAUFFEUR FACULTATIF CIRCUIT AIR MASSAGE FACULTATIF CIRCUIT HYDROMASSAGE CIRCUIT BRADENTON ...

Page 14: ...egnant women and those with heart conditions or other conditions that limit normal physical activity should consult a doctor before use REPAIR PROCEDURES Most minor scratches up to 1 64 deep and cigarette burns can be removed by sanding the area with 180 or 240 wet or dry sand paper and progressing down to 600 or 1200 grit Finally apply light buffing compound and buff area with a clean stitched co...

Page 15: ... 3 The third button is a three step wave action button a Position 1 operates the pump at a steady flow b Position 2 operates the pump at a quick wave action c Position 3 operates the pump with a slower wave action 10 Illustration K Illustration N Illustration M Illustration L JET OPERATION AND ADJUSTMENT The jets can be easily adjusted by pointing the jet nozzle in the desired direction The streng...

Page 16: ...r to aid in properly setting the tub 6 Verify that the product is level by checking the tub deck surface 7 Place the fill spout and supply lines at your desired location If you are installing the spout and supply lines on the deck of the tub mark the location first select a properly sized hole saw and drill pilot holes from the acrylic side of the product Drill the spout and supply line holes from...

Reviews: