4
Section
Important Safety Information
WARNING!
1.1.
Products manufactured by us are safe and without risk provided they are installed,
used and maintained in good working order in accordance with our instructions and
recommendations.
1.2. THIS APPLIANCE MUST BE EARTHED.
In accordance with the current edition of ‘The Plugs and Sockets etc. (Safety)
Regulations' in force at the time of installation. This appliance is intended to be
permanently connected to the fixed electrical wiring of the mains system.
1.3. DO NOT
twist the individual cable cores of the live and neutral conductors, as this
will prevent them from entering the terminal block.
1.4.
The shower unit must not be fitted where it may be exposed to freezing conditions.
Make sure that any pipework that could become frozen is properly insulated.
1.5. DO NOT
operate this appliance if it is frozen. Allow the appliance to thaw before
using again.
1.6. DO NOT
operate this appliance if water leaks from the pressure relief valve,
maintenance will be required before the appliance can be safely used.
1.7. DO NOT
fit any form of outlet flow control as the outlet acts as a vent for the tank
body. Only Mira recommended outlet fittings should be used.
1.8.
There are no user serviceable components beneath the cover of the appliance.
Only a competent tradesperson should remove the cover.
1.9.
If any of the following conditions occur, isolate the electricity and water supplies
and refer to
“To contact us”
, on the back page of this guide.
1.9.1.
If the cover is not correctly fitted and water has entered the appliance
case.
1.9.2.
If the case is damaged.
1.9.3.
If the appliance begins to make an odd noise, smell or smoke.
1.9.4.
If the appliance shows signs of a distinct change in performance, indicating
a need for maintenance.
1.9.5.
If the appliance is frozen.
1.10.
Isolate the electrical and water supply before removing the cover.
1.11.
Mains connections are exposed when the cover is removed.
1.12.
Refer to the wiring diagram before making any electrical connections.
1.13.
Ensure all electrical connections are tight, to prevent overheating.