20
Connect the hot and cold inlet supply pipework to the digital mixing valve.
Note: The inlet pipework must be flexible enough to allow 25 mm movement to
enable filters to be removed for cleaning and for maintenance of the internal
components. Failure to achieve this may result in service and repair not being
able to be carried out.
Isolating valves must be installed to both inlets (supplied) and it is recommended to
fit isolators on the outlet, close to the digital mixing valve for ease of maintenance.
Note: The direction of arrow on isolation valve to indicates direction of flow.
Run the pipes from the mixed water outlets on the digital mixing valve to the proposed
siting for the shower hose outlet, and overhead fixed arm, depending on the system
chosen.
4
Push-fit Isolators
fitted to both Inlets
Push-fit connector to the
shower outlets
Hot Inlet
Cold Inlet
Outlet 1 - Handset
Outlet 2 - Overhead