Attach breathing tube and valve covers to the gas mask, ensuring the mask is effectively sealed and functioning 

before attaching the breathing tube to the PAPR unit.

8

If, during use, the airflow from the blower assembly should noticeably decrease or stop completely, or if inhalation 

should become difficult, immediately leave the contaminated area. Decontaminate and, if necessary, check the 

PAPR.

14

After four (4) hours of continuous use, the user must leave the contaminated area, decontaminate if required, and 

inspect for damage. 

13

If the airborne contaminant is detected by odor, taste, eye irritation, or if any discomfort is felt during use, 

immediately leave the contaminated area. Decontaminate and, if necessary, check the PAPR.

15

If the battery compartment should become hot to touch, immediately turn the Power Switch to OFF. Do not 

remove the facepiece, but continue to breathe through the respirator and immediately leave the contaminated 

area. Decontaminate and, if necessary, check the PAPR.

16

Manually inspect the seals and junctions of your gas mask, breathing tube, and PAPR filter connectors to ensure 

none are drawing air. This could indicate a faulty seal somewhere in the system.

Do not permit the batteries to completely discharge during use. Always monitor battery performance and change the batteries immediately after 
use or if they expire.

10

Turn the power switch to the ON position. You should immediately notice improved airflow within your gas mask. 

9

Use of the PAPR must be in strict accordance with the guidelines and warnings contained herein. The maximum 

safe duration of use primarily depends on

12

Note

Perform a NEGATIVE LEAK PRESSURE TEST before using in the field.

11

The amount and 
type(s) of 
contaminant(s) in 
the air and the 
capacity of the 

filter elements to 

absorb and 
neutralize the 
contaminant(s).

a

The amount of 
airborne particles 
(dust) in the 
atmosphere.

b

The charge in the 
batteries.

c

The physiological 
limits of the user.

d

Page 5

Summary of Contents for MB-90

Page 1: ...MB 90 PoweredAir Purifying Respirator PAPR RD011721...

Page 2: ......

Page 3: ...EMENT NOT REPLACE EXISTING TRAINING AND PROTOCOL REGARDING THE USE OF PPE AND GAS MASKS FULL FACE RESPIRATORS PLEASE CONSULT LEADERSHIP OR RELEVANT AUTHORITIES REGARDING THE DEPLOYMENT OF THIS EQUIPME...

Page 4: ...F power switch is on the top front of the blower assembly On the front there are two 2 threaded inlets to attach 40 mm filters The MIRA Safety MB 90 PAPR can use up to two 2 filters New filters must b...

Page 5: ...respirator instruction manual for details 3 The individual using the respirator must ensure it is properly inspected before use properly decontaminated after use if necessary properly cleaned and mai...

Page 6: ...on and that the batteries are fully charged Turn the power switch ON briefly to ensure the unit is functioning Turn the power switch OFF again 1 The blower assembly and breathing tube must be arranged...

Page 7: ...rough the respirator and immediately leave the contaminated area Decontaminate and if necessary check the PAPR 16 Manually inspect the seals and junctions of your gas mask breathing tube and PAPR filt...

Page 8: ...acepiece from the breathing tube or remove the facepiece THIS WILL TERMINATE RESPIRATORY PROTECTION AND THE USER WILL BE BREATHING THE ATMOSPHERE THE RESPIRATOR WAS INTENDED TO PROTECT AGAINST PERFORM...

Page 9: ...R DEATH Termination of use occurs when the user leaves the contaminated area and does not intend to reenter Removal must be done in a fresh air environment after thorough decontamination To doff the f...

Page 10: ...tridges please contact MIRA Safety Customer Service Your MIRA Safety MB 90 PAPR comes with an enclosed breathing tube If the tube is damaged or dysfunctional in any way contact MIRA Safety for a repla...

Page 11: ...ecting sanitizing preparations used Used filter elements must be removed and disposed of as directed in the DISPOSAL OF USED FILTER ELEMENTS section of this manual CLEANINGANDSTORAGE Warning INSPECT T...

Page 12: ...Rinse thoroughly with clean water 3 DO NOT STORE BATTERIES IN THE BLOWER UNIT Store AA batteries separately according to the manufacturer s guidance 1 Store the MIRA Safety MB 90 PAPR blower belt and...

Page 13: ...purchase may be required 2 Return the product to the retailer where the product was purchased for an exchange provided that the store is a participating retailer Returns to a retailer should be made w...

Page 14: ...1 N FM 620 RD STE 259 155 Austin TX 78726 2021 MIRA Safety LLC MIRA Safety the MIRA Safety logo and MB 90 are registered and or unregistered marks of MIRA Safety LLC or its affiliates 888 316 1462 sup...

Reviews: