Warning
IF THE POSITIVE AIR PRESSURE
FROM THE BLOWER CEASES FOR
ANY REASON, LEAVE THE
CONTAMINATED AREA AS SOON AS
IT IS SAFE TO DO SO. A LACK OF
POSITIVE AIR PRESSURE FROM THE
BLOWER MAY REDUCE THE
PROTECTION PROVIDED BY THE
RESPIRATOR, WHICH COULD
RESULT IN SERIOUS INJURY OR
DEATH.
Warning
IF YOU DETECT ANY CONTAMINANT
ODOR OR TASTE, OR EXPERIENCE
IRRITATION OF THE EYES, NOSE OR
THROAT, THERE MAY BE EXPOSURE
TO THE CONTAMINANT. RETURN TO
FRESH AIR IMMEDIATELY.
DETERMINE THE REASON FOR THE
EXPOSURE AND TAKE APPROPRIATE
CORRECTIVE ACTION BEFORE
CONTINUING USE OF THE
RESPIRATOR. FAILURE TO TAKE THE
PROPER CORRECTIVE ACTION MAY
RESULT IN EXPOSURE TO THE
CONTAMINANT, WHICH COULD
CAUSE SERIOUS INJURY OR DEATH.
Warning
IF THE BATTERY COMPARTMENT
BECOMES HOT, IMMEDIATELY
LEAVE THE AREA REQUIRING
RESPIRATORY PROTECTION. TURN
OFF THE EQUIPMENT AND ALLOW
IT TO COOL AT LEAST 60 MINUTES
BEFORE REMOVING THE BATTERY
PACK. DO NOT HANDLE BATTERIES
DIRECTLY IF YOU SMELL AN ACRID
ODOR.
The MIRA Safety MB-90 PAPR is designed to be used with a wide variety of CBRN gas
masks/full-face respirators and compatible NATO standard 40
mm filter cartridges. The
essential operation of this PAPR remains the same, provided you adhere to all
guidelines and instructions for your mask and filter cartridge.
To use your MIRA Safety MB-90 PAPR
USING YOUR MB90- PAPR
Ensure the power switch is in the OFF position and that the batteries are fully
charged. Turn the power switch ON briefly to ensure the unit is functioning.
Turn the power switch OFF again.
1
The blower assembly and breathing tube must be arranged so that
There is enough slack in the
breathing tube for the user
to turn their head through
the full range of motion
without the breathing tube
pulling on the facepiece, the
breathing tube being
pinched closed, or the
breathing tube interfering
with other protective
clothing or equipment.
7
Inspect the PAPR and breathing tube as outlined in the PAPR MAINTENANCE
AND INSPECTION section of this manual.
2
Attach two (2
) filter elements to the PAPR housing by threading them onto the
inlet ports until hand tight. DO NOT OVER TIGHTEN FILTER ELEMENTS.
3
Insert eight (8) fully charged AA batteries into the battery holder, ensuring
correct polarity. Then insert the battery holder into the battery compartment,
inspecting the battery compartment for any signs of corrosion before
installing.
4
Don the waist belt with blower assembly so the breathing tube outlet is at the
top of the unit. Fasten the buckle and adjust the waist belt.
5
Position the blower assembly at the back of either the right or left hip. When
properly donned, the power switch should be accessible.
6
a
The PAPR blower assembly
and breathing tube must be
positioned so that excessive
slack in the breathing tube
is not likely to catch on
objects.
b
If additional protective
clothing is used, it must be
arranged so that it does not
interfere with the fit of the
gas mask or restrict airflow
to the filter elements.
c
Page 4