background image

17

CoMMIssIonInG

Maximum Temperature setting

Before using the shower, the maximum temperature must be checked to make sure 

that it is at a safe level. It has been preset to a safe showering temperature under 

ideal conditions at the factory, appropriate for most systems. However, site conditions 

and personal preference may make it necessary to reset this temperature.

note!

 Make sure that the hot water temperature is at least 55°C and that there is 

sufficient supply. 

Caution!

 Before testing the mixer, make sure that the hot and cold water is flowing 

correctly by exercising the temperature selector knob between the cold and hot 

stops.

1.

  Turn the temperature selector knob to position 7 and test that the temperature 

of the water from the shower outlet is hot enough.

2.

  If not, depress the override button and 

carefully 

rotate towards position 9. If the 

water temperature is still not hot enough complete the following procedure.

3.

  rotate the temperature selector knob back to position 7.

4.

  Using a suitable screwdriver carefully pry off the concealing cap and unscrew 

the fixing screw.

5.

  Pull off the temperature selector knob without disturbing the stop assembly.

6.

  replace the temperature selector knob so that the 6 mark is in line with the 

stop assembly.

7.

  rotate  the  temperature  selector  knob  to  position  7,  wait  for  the  water  to 

stabilise and test that the temperature of the water from the shower outlet is 

hot enough.

 

If the water temperature is still not hot enough repeat the procedure until a 

maximum safe temperature is achieved at position 9.

8.

  Refit and tighten the fixing screw, refit the concealing cap.

Fixing screw

Concealing Cap

stop assembly

Temperature 

selector Knob

Summary of Contents for Coda Plus

Page 1: ...1 These instructions must be left with the user Installation User Guide Mira Coda Plus C o d a P l u s THERMOSTATIC BAR VALVE...

Page 2: ...nsions 7 Installation 8 Suitable Plumbing Systems 8 General 8 Installation 10 Installation with Fixed Pipework 15 Commissioning 17 Maximum Temperature Setting 17 Operation 18 Adjusting the Temperature...

Page 3: ...temperature stop is provided which limits the temperature to a safe level Inlet filters are fitted to protect the thermostatic cartridge The Mira Coda Plus is supplied complete with a patent applied f...

Page 4: ...ttings for one year For non domestic installations Mira Showers guarantee the Mira Coda Plus against any defect in materials or workmanship for a period of one year from the date of purchase For terms...

Page 5: ...tained in accordance with the manufacturer s recommendations 2 Periodic attention is given when necessary to maintain the product in good functional order Caution 1 Read all of these instructions 2 Re...

Page 6: ...ar Valve Fixing Kit Installation Template Pack Contents Tick the appropriate boxes to familiarise yourself with the part names and to confirm that the parts are included Documentation q 1 x Guarantee...

Page 7: ...atures up to 85 C for short periods without damage However for safety reasons it is recommended that the maximum hot water temperature is limited to 65 C Minimum Recommended Differential between Hot S...

Page 8: ...iler Unvented Mains Pressure System The thermostatic mixer can be installed with an unvented stored hot water system Mains Pressurised Instantaneous Hot Water System The thermostatic mixer can be inst...

Page 9: ...alves must be installed close to the mixer for ease of maintenance 4 Pipework must be rigidly supported and avoid any strain on the connections 5 Pipework dead legs should be kept to a minimum 6 Decid...

Page 10: ...ry important as the Mira Coda Plus does not allow for reversed inlets 1 5 If pipework is chased into a solid wall in accordance with UK Water Regulations it must be accessible 1 6 Pipes must be straig...

Page 11: ...Pipework when instructed this will avoid cracking tiles 6 Mark the pipe distance 25 5 mm from the finished wall and cut to length Important If using plastic pipes then they should be cut to suit the i...

Page 12: ...the screws supplied 10 Tighten the nuts 11 Carefully push the offset connectors onto the wall brackets Using the finger grips rotate them clockwise until the lug hits the stop Important If at step 4 t...

Page 13: ...inger grips rotate the connectors anti clockwise to adjust the centres 15 Loosely screw the concealing plates onto the offset connectors Important Do not fully tighten at this stage 16 Make sure that...

Page 14: ...to turn until the valve is level Note The nuts can be rotated anti clockwise without disengaging from the offset connector until the stop point on the wall bracket is reached at this point the nut wil...

Page 15: ...ition 1 Fit the locking washers over the offset connectors 2 Loosely fit the screws to hold the offset connectors in place 5 Caution It is essential at this point that the supply pipework is thoroughl...

Page 16: ...tted in the correct orientation offer the bar valve up to the offset connectors and tighten the nuts Caution Do not overtighten Caution Take care not to damage the chrome plated surfaces 9 Before usin...

Page 17: ...ower outlet is hot enough 2 If not depress the override button and carefully rotate towards position 9 If the water temperature is still not hot enough complete the following procedure 3 Rotate the te...

Page 18: ...ing the Temperature The temperature is controlled by rotating the temperature selector knob For safety reasons the temperature is limited by an override stop To obtain a higher temperature press the o...

Page 19: ...ockage Make sure that the maintained inlet pressures are nominally balanced and sufficient refer to section Specifications Make sure that the inlet temperature differentials are sufficient refer to se...

Page 20: ...ntain abrasive and chemical substances and should not be used for cleaning plated or plastic fittings Do not use descalents on this product Bar Valve Removal 1 Isolate the hot and cold water supplies...

Page 21: ...tatic bar valve removed remove the sealing washer filter 2 Unscrew the non return valve housing using a 12 mm hexagonal wrench Note The non return valve housing has a Left Hand Thread turn clockwise t...

Page 22: ...Cartridge 1663 311 Inlet Connector 1630 054 Temperature Stop Assembly 1663 114 Thermostatic Cartridge 1630 048 Outlet Connector 1712 040 Fixing Kit Component Pack 1712 038 Fixing Kit Assembly 1712 03...

Page 23: ...ot in use Maximum User Weight 127 kg 20 stone note Must be installed onto a solid wall Premium shower seat White Chrome 2 1731 001 Grey Chrome 2 1731 002 stylish slim line and robust shower seat for u...

Page 24: ...l If the performance of your product declines check in this manual to see if simple home maintenance is required If you require further assistance call our Customer services Team extended Guarantees a...

Reviews: