22
Inner Temperature
Control Knob
Disabling the Temperature Override Button
The temperature override button allows the user to override the preset maximum
temperature. The temperature override button should be disabled if the power shower
is to be used by the young, the elderly, the infirm, or anyone inexperienced in the
correct operation of the controls.
Follow the instructions below to disable the temperature override button:
1.
Turn the outer flow control knob
clockwise
to the off position and
the inner temperature control knob
clockwise
to full cold.
2.
Slide the end of the push-fit release
tool under the outer flow control knob
and lever the control knob assembly
off the shower unit.
3.
Unclip the concealed end of the
override button from the temperature
indicator trim and carefully remove the
override button.
4.
Rotate the override button through
half a turn (180°) and refit. Make sure
the override button is flush with the
temperature indicator trim.
5.
Insert the outer flow control knob in
the off position.
6.
Insert the temperature indicator trim
and the inner temperature control
knob. Make sure the inner temperature
control knob is pushed fully onto the
temperature hub.
7.
The temperature override button is
now disabled.
Temperature Indicator Trim
Override Button
Full Cold Position
Off Position
Flow Control
Knob
Arrow / OFF
Position