14
3.
Make sure that the end of the supply
pipework is cut squarely and is
free
from burrs
, which will damage the
inlet manifold seals.
Chamfer the end of the pipe to assist
insertion into the fitting and prevent
the ‘O’ seal tearing.
Warning!
Do not
insert fingers into
the push-fit connectors as this can
result in injury.
Caution!
Thoroughly flush the
incoming hot and cold water supply
pipes to remove debris before
connecting the shower unit.
4.
Run the electrical supply cable in
surface mounted miniature trunking
(not supplied). Allow sufficient cable
to connect to the terminal block
(approximately 275 mm). Strip back
approximately 30 mm of outer cable
insulation.
5.
Loosen the three cover securing
screws and remove the shower unit
cover.
Note!
The cover securing screws
are captive and should
not
be
unscrewed fully from the unit case.
6.
Insert the push-fit release tool
between the flange of the blanking
plug and the inlet manifold collet
and lever the plugs outward. Whilst
holding back on the collet, pull out
the appropriate blanking plug by
hand.
Chamfer
Trim the thinned section of
the case covering the cable
channel.
Push-fit
Release Tool
Blanking Plug
Inlet Manifold
Collet
Securing
Screws
Securing Screw