MIR 911003 User Manual Download Page 2

MiniSpir Light

 

User manual

 

 

 

 

MINISPIR LIGHT User manual 

Rev 1.7   

page 2 di 13 

 

 

Thank you for choosing a

 

product from

 MIR

 

MEDICAL INTERNATIONAL RESEARCH 

 

WARNING

 

 

The paper mouthpiece, the nose clip and the disposable turbine with mouthpiece in the equipment should be considered 
disposable products. 

 

Before using your MiniSpir Light 

… 

 

Read this manual carefully, plus all labels and other product information supplied. 

 

Set  the  device  configuration  (date,  time,  predicted  values,  language  etc.)  as  described  in  the  Software  WinspiroLIGHT 
Manual. 

 

Check  PC  system  requirements  for  compatibility  with  the  device  (RAM:  512  Mb  minimum,  1024  Mb  preferred;  Operating 
system: Windows 2000 

– XP Windows Vista (32bit/64bit)- Windows 7 (32bit/64bit); Windows 10 (32bit/64bit); Minimum disk 

space: 500 Mb; CPU Pentium IV-class PC 1 GHz; display resolution 1024x768 or higher. 

 

MiniSpir Light

 should only be connected to a computer manufactured in compliance with EN 60950.

 

 

WARNING

 

 

The  winspiroLIGHT  PC  software  supplied  with  the  device  MUST  be  installed  correctly  to  the  PC  before  connecting 
MiniSpir Light to the PC. At the end of the installation, connect the device to the PC and the hardware will be "recognised" 
by the PC. The device can then be used with the winspiroLIGHT software. 

 

Keep the original packaging! 

In  the  event  that  your  device  requires  attention  then  always  use  the  original  packaging  to  return  it  to  the  distributor  or  the 
manufacturer. 
 
In such an event then please follow these guidelines: 
 

  Return the complete device in the original packaging, and 

  The transport (plus any customs or taxes) costs must be prepaid. 

 
Manufacturer’s address 
 

MIR SRL:  

Via del Maggiolino, 125 
00155 ROME (ITALY) 
Tel + 39 0622754777  

 

  

Fax + 39 0622754785 

Web site: www.spirometry.com 

 

Email: [email protected] 

 

MIR USA, Inc. 

5462 S. Westridge Drive 
New Berlin, WI 53151 - USA 
Tel + 1 (262) 565 

– 6797   

 

Fax + 1 (262) 364 

– 2030 

Web site: www.spirometry.com 

 

Email: [email protected] 

 
 

MIR  has  a  policy  of  continuous  product  development  and  improvement,  and  the  manufacturer therefore  reserves  the 
right  to  modify  and  to  update  the  information  contained  in  this  User’s  Manual  as  required  Any  suggestions  and  or 
comments regarding this product should be sent via email to[email protected]
Thank you. 
MIR accepts no responsibility for any loss or damage caused by the User of the device due to the use of this Manual 
and/or due to an incorrect use of the product. 
Copying this manual in whole or in part is strictly forbidden. 

 

FEDERAL LAW RESTRICTS THIS DEVICE TO SALE BY OR ON THE ORDER OF A PHYSICIAN 

 

Summary of Contents for 911003

Page 1: ...MiniSpir Light User manual MINISPIR LIGHT User manual Rev 1 7 page 1 di 13 User Manual Rev 1 7 Issued on 09 10 2020 Approved on 09 10 2020...

Page 2: ...recognised by the PC The device can then be used with the winspiroLIGHT software Keep the original packaging In the event that your device requires attention then always use the original packaging to...

Page 3: ...1 2 4 Device 6 1 2 5 Warnings for use in electromagnetic environments 6 1 3 Unforeseen errors 6 1 4 Labels and symbols 7 1 4 1 Identification label 7 Warning symbol for the WEEE 7 1 4 2 ESD Electrosta...

Page 4: ...quires installation by qualified personnel 1 1 5 Subject effect on the use of the device A spirometry test should only be carried out when the subject is at rest and in good health and thus in a suita...

Page 5: ...liquids Do not allow dust or foreign bodies to enter the turbine sensor in order to avoid incorrect functioning and possible damage The presence of any impurities such as hair sputum threads etc withi...

Page 6: ...ngs for use in electromagnetic environments Due to the increasing number of electronic devices computers cordless phones cell phones etc medical devices may be subject to electromagnetic interference...

Page 7: ...to return the device without charge to the dealer or distributor when a new equivalent device is purchased Due to the materials used in the manufacturing of the device disposing it as a normal waste...

Page 8: ...from a conductive material of equivalent size Some well known insulators are common plastics and glass An insulator will hold the charge and cannot be grounded and conduct the charge away Both conduct...

Page 9: ...online manual of the WinspiroLIGHT Software MiniSpir Light is able to make FVC VC IVC tests calculates an index of test acceptability quality control plus reproducibility of the spirometry tests carri...

Page 10: ...Radio Frequency Immunity 3V m 80 2700 MHz MIR will make available on request circuit diagrams component part lists descriptions calibration instructions or other information that will assist service...

Page 11: ...rately severe severe very severe Through an analysis applied to some of the indices and parameters calculated in the FVC test MiniSpir Light produces a variety of quality control comments useful to un...

Page 12: ...nnected to a PC via USB Upgrades can be downloaded by registering on www spirometry com For further information on upgrading software see the winspiroLIGHT software manual 4 MAINTENANCE WARNING No par...

Page 13: ...alteration adjustment modification or repair has been carried out by personnel not authorised by MIR If the fault is caused by lack of or incorrect routine maintenance of the machine If the machine ha...

Reviews: