TROUBLESHOOTING 

Symptom  

Meaning 

What to do  

Status LED flashing 20 times 

Device is on/ awake 

Device is working as it should, leave 
device to collect data 

Cellular LED solid 

Device connected to 
LTE network 

Device is working as it should, leave 
device to collect data 

Status LED won’t turn on after 
using the magnet 

The device battery may be 
depleted, or a device fault may 
have occurred  

Use a different device and contact 
the supplier 

Status LED flashing in 
sequence: 2 long 1 short 

No cellular registration 
(connection to the network) is 
being achieved. 

Check with the Telstra coverage map 
to ensure the site is covered by the 
LTE-M or NBIoT cellular network.  

If the area is covered, and the device 
cannot connect, contact the supplier.

 

Status LED flashing in 
sequence: 2 long 8 short 

Captis device cellular module 
failed to boot 

Return the device to the supplier if 
the issue persists.  

Sensor connection not working 
(not flashing the LED after LED 
flash turned on in Captis 
Configuration Toolset) 

Connection wired incorrectly  

Confirm that the sensor is properly 
attached.  

Contact support if issue persists 

Sensor readings not uploading 
to/ appearing in Cumulocity 

Sensor not triggering  

Ensure the sensor can be triggered 
by checking that the sensor is 
securely installed. 

Contact support if issue persists 

No cellular signal  

Check Status and Cellular LED.  

If flashing, complete troubleshooting 
for a flashing Cellular LED. 

Contact support if issue persists 

 

 

Summary of Contents for Captis Metrum

Page 1: ...mIoT Captis Installation Guide March 2020 1 Rev 5 Installation Guide Captis Metrum Itron TD8...

Page 2: ...nsion 3 Captis Metrum 3 Installation 4 Before you begin 4 What is in the Captis Box 4 Installing the Captis 5 Terminating the device 5 Mounting the Captis 6 Checking Sensor Cellular Connections 8 Trou...

Page 3: ...r via a pulse pick up unit It is battery operated and does not require an external power supply It operates on LTE M or NB IoT cellular networks The enclosure is IP68 rated CAPTIS TECHNICAL INFORMATIO...

Page 4: ...e water meter that will be connected to the Captis A 3mm Allen key and small flat blade screwdriver An internet connected device such as a phone or tablet WHAT IS IN THE CAPTIS BOX In the Captis box y...

Page 5: ...unt the Captis Metrum to the Itron TD8 water meter 2 Test the wiring sensor and cellular connection 3 Complete the physical installation after testing TERMINATING THE DEVICE The Itron TD8 Cyble Sensor...

Page 6: ...8 water meter and can be installed following these steps 1 Pass the supplied mounting band around the TD8 and secure with the supplied screw and a 3mm Allen Key 2 Carefully install the Cyble Sensor at...

Page 7: ...4 Place the supplied Cable cover over the pickup and Metrum cable entry and clip into the attachment band to secure 5 Screw the Cyble Sensor to the Itron TD8 water meter using the white plastic screw...

Page 8: ...CHECKING THE CELLULAR CONNECTION OF AN ENCLOSED DEVICE If you are installing your Captis device in an enclosed space i e a pit or cabinet then you must check the connectivity of the device in the env...

Page 9: ...he site is covered by the LTE M or NBIoT cellular network If the area is covered and the device cannot connect contact the supplier Status LED flashing in sequence 2 long 8 short Captis device cellula...

Page 10: ...the device or antenna while device is transmitting Device is transmitting when the Cellular LED is lit BATTERY HANDLING DISPOSAL This Captis devices uses a Lithium ION Battery The Captis device shoul...

Reviews: