37. Daily or once per 4 hours of operation, let the compressed air out of the receiver.
Pour down the condensate from the receiver’s bottom on a regular basis.
38. Do not stop the compressor through pulling the plug out of the socket. Firstly you
should push down the pressure control relay lever (turn to “OFF” — “switched off”, and
then take the plug out of the socket).
39. The applied tools, parts and components of the pipeline shall be intended for the
working pressure of the compressor. Otherwise there might be a threat of explosion.
5. ACTIONS TO BE TAKEN PRIOR TO START-UP
Prior to each start of the compressor, one should make sure that all the parts may
duly and properly function, the moving parts can easily be moved, the protective ele
ments serve for the safe operation. Any damaged part shall be subject to immediate
replacement by the specialized repair shop or the service centre, excluding the cases as
stipulated herein. Repair on your own is prohibited.
1. Unpack the compressor (install the wheels, using the fasteners enclosed)
(Fig. 5,
6, 7)
.
2. Make sure that the electric network is compatible with the requirements as men
tioned herein.
3. Make sure that the switch relay is in the off condition. Connect the electric cord to
the socket.
4. Open the liquid escape valve from the receiver (it is essential to make the initial
start of the compressor easier and to speed up the lubrication process on the cylinders’
block).
5. Switch on the compressor (the electric motor will start working). Make sure the
motor’s impeller is rotating (there is a blowoff) and the air comes out from the valve
nipple.
ATTENTION!
Do not place your hand under the air flow. It may cause an injury.
6. Approximately in 5 minutes please close the valve and check the functioning of
the switch relay and manometers.
7. To the quickdetachable connection attach the good external line and pneumatic
tool. Check the functioning of the output reducer.
8. Switch off the compressor and bleed the air through the protective valve. Should
all the checks have gone alright, you may start working. Otherwise contact the trading
organization or the service centre for consultancies.
6. ІНСТРУКЦІЇ З ЕКСПЛУАТАЦІЇ
1. The compressor installation place shall be clean, dry and ventilated.
2. When the compressor is on the power shall be supported at ±5% from the rated
one.
3. Sustain the oil level in the compressor within the sector.
4. Open the output valve, put the membrane switch button in the position “ON”
(Fig. 4)
and start the compressor idling for 10 minutes, to make sure that all the moving
parts are lubricated enough before the next operation.
ENGLIS
H
3–4
Summary of Contents for 81-190
Page 2: ...2 0 40 4 1 2 3 4 5 6 7 8 9 10 11 12 13 5 2 14 15 16 17 18 19 FF 1 2 220 2 1 5 16 2...
Page 3: ...20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 1 3...
Page 4: ...35 36 37 4 38 OFF 39 5 1 5 6 7 2 3 4 5 6 5 7 8 6 1 2 5 1 4...
Page 5: ...3 4 4 10 4 1 2 3 4 5 6 4 7 7 1 20 2 20 30 5546 86 25284079 001 98 15W40 5W30 SAE 3 60 1 5...
Page 6: ...4 500 8 9 4 81 190 5 1 1 3 6 50 6 5 1 2 1 4 6 6 6 1 1 6...
Page 10: ...5 6 1 10...
Page 11: ...11 MIOL 8 61020 057 783 30 55 057 783 33 54 050 4 010 797 e mail servis miol gmail com 1 11...
Page 12: ......
Page 14: ...2 0 40 4 1 2 3 4 5 6 7 8 9 10 11 12 13 5 2 14 15 16 17 18 19 OFF 220 2 1 5 16 2 2 2...
Page 15: ...20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 2 3...
Page 16: ...35 36 37 4 38 OFF 39 5 1 5 6 7 2 3 4 5 6 5 7 8 6 1 2 5 3 2 4...
Page 17: ...4 4 10 4 1 2 3 4 5 6 4 7 7 1 20 2 20 30 5546 86 25284079 001 98 15W40 5W30 SAE 3 60 2 5...
Page 18: ...4 500 8 9 4 81 190 5 1 1 3 6 50 6 5 1 2 1 4 6 6 6 1 2 6...
Page 22: ...5 6 2 10...
Page 23: ...11 MIOL 8 61020 057 783 30 55 057 783 33 54 050 4 010 797 e mail servis miol gmail com 2 11...
Page 24: ......
Page 35: ...APPENDIX 5 81 190 5 81 190 Fig 5 Layout of compressor 81 190...
Page 36: ...6 81 191 6 81 191 Fig 6 Layout of compressor 81 191...
Page 37: ...7 81 195 7 81 195 Fig 7 Layout of compressor 81 195...