The SmartSine UPS has a removable receptacle panel.  The receptacle panel
can be configured with one locking receptacle and two duplex receptacles.
This will allow the user to customize the output receptacles for their specific
applications.  MINUTEMAN will only use UL or CE approved receptacles.  Here
is one example that could be used: one L5-20R, two 5-15/20R duplexes.  To
customize your MINUTEMAN UPS for your specific application, contact your
local distributor or contact MINUTEMAN at 1-972-446-7363, 1-800-238-7272 or
fax 1-972-446-9011to find out which output receptacle options are available.
Come visit our web site at www.minutemanups.com to find out about all the
Power Protection products available from MINUTEMAN.

MINUTEMAN reserves the right to make changes without notice.

Customized Output Receptacle Panels

Summary of Contents for SMARTSINE

Page 1: ...User s Manual ...

Page 2: ... Controls and Indicators 4 3 Installation 6 4 Operation 9 5 Troubleshooting 11 6 Replacing the Battery 12 7 Obtaining Service 15 8 Specifications 16 9 Configurable Parameters Settings 17 10 Limited Product Warranty 19 11 Declaration of Conformity 21 English SmartSine ...

Page 3: ...r television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Thank you for purchasing a MINUTEMAN power protection product It has been designed and manufactured to provide many years of trouble free service Please read the manual before installing your SmartSine UPS It provides ...

Page 4: ...r outlet before installing a computer interface cable Reconnect the power cord only after all signaling connections are made CAUTION Connect the UPS to a two pole three wire grounding AC power outlet The receptacle must be connected to appropriate branch protection circuit breaker or fuse Connection to any other type of receptacle may result in a shock hazard and violate local electrical codes Eng...

Page 5: ...ility of Para Systems Inc is adequately protected under the circumstances Examples of devices considered to be life support devices are neonatal oxygen analyzers nerve stimulators whether used for anesthesia pain relief or other purposes auto transfusion devices blood pumps defibrillators arrhythmia detectors and alarms pacemakers hemodialysis systems peritoneal dialysis systems neonatal ventilato...

Page 6: ...ying battery power to the load The LED blinks and no audible alarm when the UPS is in either the boost or the buck mode The Fault red LED illuminates when the UPS has detected an internal fault see section 5 The Overload yellow LED illuminates when the loads connected to the UPS exceeds the UPS power rating see section 5 The Weak Bad Battery red LED illuminates when the UPS has detected that the b...

Page 7: ...ting Serial number label 5 The Smart Slot is for MINUTEMAN option cards 6 The output circuit breakers will trip in the event the individual banks of the output receptacles exceed the rating of the circuit breaker Not on all models 7 The input power cord has a NEMA 5 15P or 5 20P S 2000 connector 8 The input circuit breaker will trip in the event the load exceeds the UPS s power rating 9 The DIP Sw...

Page 8: ...evation 0 to 3 000m 0 to 10 000 ft Operating and Storage Relative Humidity 95 non condensing Storage Temperature 15 to 45 degrees C 5 to 113 degrees F Storage Elevation 0 to 15 000m 0 to 50 000 ft CONNECTING YOUR EQUIPMENT CAUTION DO NOT connect a laser printer to the output receptacles on the UPS unless the UPS is rated 2000VA or greater A laser printer draws significantly more power when printin...

Page 9: ...rface cables kits can be used with the SmartSine UPS Use only MINUTEMAN or MINUTEMAN approved interface cables with these UPSs Connect the interface cable to the 9 pin communications port on the rear panel of the UPS Secure the connector to the UPS via the screws on the connector housing Connect the other end of the cable to the device that will be monitoring controlling the UPS TELEPHONE NETWORK ...

Page 10: ... test that is automatically performed every two weeks is longer than the start up or user invoked test This test will run for approximately fifteen seconds to measure the battery s capability to provide an acceptable amount of runtime If the UPS fails a self test one of the LEDs will remain illuminated indicating the type of problem see section 5 Troubleshooting Note The UPS will automatically per...

Page 11: ... seconds The alarm will stop once the UPS returns to the On Line operation UPS FAULT When the UPS detects a hardware fault the Fault LED will illuminate and the UPS will emit a sustained tone The fault condition in some instances may be reset by turning the UPS OFF and then ON see section 5 Troubleshooting OVERLOAD When the amount of load attached to the UPS exceeds its power rating the Overload L...

Page 12: ...t Site Wiring Fault LED is illuminated Have a Qualified Electrician correct the service wiring The batteries may be weak or at the end of useful service life Charge the batteries for 8 hours and retest If the runtime is still less than expected the batteries may need to be replaced even though the Weak Bad Battery LED is not illuminated UPS does not provide expected runtime Weak Bad Battery LED is...

Page 13: ...ies properly The batteries contain lead and pose a hazard to the environment and human health if not disposed of properly Refer to local codes for proper disposal requirements or return the battery to MINUTEMAN Although battery system voltages are only 24VDC the battery system can still present a risk of electrical shock The current capability of a battery is sufficent to burn wire or tools very r...

Page 14: ...panel to turn the UPS OFF 3 Unplug the UPS s AC power cord from the AC outlet 4 Unplug the equipment from the output receptacles of the UPS 5 Remove the front panel of the UPS 6 Lay the front panel on top of the UPS 7 Remove the two retaining screws and the battery retaining bracket English S 700 S 1000 S 1400 Battery Model 2 12V7Ah 2 12V12Ah 2 12V17Ah S 2000 2 12V17Ah SmartSine Model Replace batt...

Page 15: ...e new batteries 14 Slide the new batteries into the battery compartment far enough to connect the battery negative wire 15 Verify proper polarity Reconnect the battery negative black wire to the battery negative terminal 16 Slide the batteries the rest of the way into the battery compartment 17 Verify proper polarity Reconnect the battery positive red wire to the battery positive terminal Some spa...

Page 16: ...ssible F A technician will ask you for the above information and if possible help solve your problem over the phone In the event that the unit requires factory service the technician will issue you a Return Material Authorization Number RMA G If the UPS is under warranty the repairs will be done at no charge If not there will be a charge for repair 4 Pack the UPS in its original packaging If the o...

Page 17: ...scharge Noise filter Surge voltage let through as a percentage of an applied ANSI C62 41 Cat A 6 kV Surge response time 2 12V17Ah Surge current capability one time 8 20 uS waveform 6500 Amps total Surge energy rating one time 10 1000 uS waveform Protection On battery waveshape Over current short circuit protected and latching shutdown True Sine Wave On battery frequency 50 60 Hz 5 Hz unless synchr...

Page 18: ...r environment or leave factory default Enter the current date when replacing batteries Use this function to uniquely identify the UPS in your network configuration Changes output voltage during battery mode operations UPS Output When the UPS is told to shut down it turns off the UPS output only UPS Turns off the UPS which requires the UPS to be turned on manually Enabled the UPS will emit a short ...

Page 19: ... one example that could be used one L5 20R two 5 15 20R duplexes To customize your MINUTEMAN UPS for your specific application contact your local distributor or contact MINUTEMAN at 1 972 446 7363 1 800 238 7272 or fax 1 972 446 9011to find out which output receptacle options are available Come visit our web site at www minutemanups com to find out about all the Power Protection products available...

Page 20: ...roperly registered the product within 10 days of purchase The warranty shall be void if a the equipment is damaged by the customer is improperly used is subjected to an adverse operating environment or is operated outside the limits of its electrical specifications b the equipment is repaired or modified by anyone other than Para Systems or Para Systems approved personnel or c has been used in a m...

Page 21: ...s or otherwise The sole and exclusive remedy for breach of any warranty expressed or implied concerning Para Systems s products and the only obligation of Para Systems hereunder shall be the repair or replacement of defective equipment components or parts or at Para Systems s option refund of the purchase price or substitution with an equivalent replacement product This warranty gives you specific...

Page 22: ... Manufacturer s Address 1455 LeMay Drive Carrollton Texas 75007 USA Type of Equipment Uninterruptible Power Supplies UPS Model No S 700 Y S 1000 Y S 1400 Y S 2000 Y I the undersigned hereby declare that the equipment specified above conforms to the above Directive s Place Carrollton Texas USA Robert Calhoun Signature Date June 3 2002 Robert Calhoun Name Manager Engineering Position Year of Manufac...

Page 23: ...24 English Notes 22 ...

Page 24: ...Para Systems Inc 1455 Lemay Dr Carrollton TX 75007 Phone 1 972 446 7363 Fax 1 972 446 9011 Internet minutemanups com UPS Sizing sizemyups com PN 34000196 Rev 0 ...