Machine Operation
To Charge Batteries:
When the battery / fault gauge reaches the red zone the batteries need to be recharged. Take the machine to a well ventilated area, unwind
the battery charger power cord from the electrical box cover and plug into an appropriate power source. After approximately 10 seconds the
battery charge status indicator will turn on.
For Wet batteries only:
Check the battery water levels before each use, refi ll as needed with distilled water.
Caution: DO NOT OVERFILL. Fill water 1/4 “ - 1/2” above the separators. Failure to maintain the batteries may result in battery
failures.
WARNING: Charging batteries generates explosive gasses. Do not charge batteries when open fl ames or sparks are present. Do not
smoke. Charge the batteries in a well-ventilated area .
Solution Solenoid
Solution solenoid will operate when the brush motor is turned on. The solution lever must be moved to the desired operating position, but
does not need to be moved to the closed position when stopping for brief periods.
Hour Meter (Optional):
Hour meter will automatically record operating time of the brush motor.