background image

6

13

The electronic controller can detect and signal several alarm conditions: high/low freezer temperatures, 

door open and open or short-circuited temperature probes. If the alarm conditions last longer than pre-

programmed time delays, the controller will turn ON an audio signal (buzzer). Also a LED light located 

in the upper left corner of the controller, next to the caution symbol, will glow in case an alarm is active. 

 

Once the alarm conditions have been fixed, the controller will turn off the alarms on its own. Alarms can 

be disabled by pressing any controller button, during alarm conditions

CONTROLLER ALARMS AND SIGNALS     

Message

Cause

Action

Prl diSC

Cabinet temperature probe open

• Check connections 

• Replace probe

Prl Short CC

Cabinet temperature probe short-circuited

 

Pr2 diSC

Defrost probe open

• Check connection 

• Replace probe

Pr2 Short CC

Defrost probe short-circuited

 

Int Error

Internal memory error

• Replace controller

Locate the electronic control on the right of the front bottom grill. The electronic control displays ac-

tual temperature inside the freezer.  In addition, the electronic control turns the refrigeration system OFF 

when freezer reaches the set temperature, and turns the refrigeration system ON after the freezer       

temperature rises by 8°F or after 7 minutes, whichever lasts longer.

TEMPERATURE ADJUSTMENT AND SWITCH FUNCTIONS     

ELECTRONIC CONTROLLER

LIGHT

POWER

ELECTRONIC CONTROL

To adjust the set temperature, follow these steps: 

1. Press  and release P    button; the set temperature and SP1 are displayed alternatively on the controller 

2. Press the UP or DOWN buttons to adjust the set temperature. 

3. Press P to store the adjusted value; The electronic control will return to cabinet temperature 

    display. The U Button on the electronic controller is used for displaying cabinet and defrost 

    temperatures (PR1 and PR2 parameters) 

1. POWER switch turns the refrigeration system (including all electrical parts) ON or OFF. 

    (use a pen or pencil to press the power switch to the ON or OFF position). 

2. LIGHT switch turns the internal and external lights ON or OFF. 

There are two switches located on the right hand side of the controller. 

Their functions are to manually switch electronic components of the freezer. 

Remove  the  plastic  screw 

covers  from  the  right  hand 

side of the display.  

With  a  screwdriver  remove 

the two screws from the right 

hand side of the display.

Slide the right hand display end 

cap from the display frame.

ISD TRANS-LIGHT LED STRIP REPLACEMENT (IF EQUIPPED)

    

Disconnect  LED  strip  wires 

from connectors and peel LED 

strips off freezer.

Install replacement LED strips 

at the same place and connect 

wires. Observe color coding.

WARNING

 

Make sure the freezer is disconnected from the power supply before any service. Press the        

freezer switch to the “Off” position then unplug the power cord from electrical receptacle.  

All service work must be conducted by a certified technician only.

Slide  the  diffuser  panel  and 

graphic panel (if used) out of 

the frame channel.

Replace the diffuser panel and 

graphic panel (if used).

Replace the display end cap.

Replace  the  two  screws  on 

the display end cap.

Summary of Contents for 20X-UDGF

Page 1: ... the left hand inside wall of the cabinet We advise you to keep this Owners Manual and sales slip in your possession Owners Manual 24 Deep Glass Door Freezers Double Door Models 20X UDGF 43X UDGF tel 800 800 5706 905 702 1441 fax 905 702 1442 MINUSFORTY com 30 Armstrong Ave Georgetown Ontario Canada L7G 4R9 30 Armstrong Avenue Georgetown Ontario Canada L7G 4R9 tel 800 800 5706 or 905 702 1441 fax ...

Page 2: ......

Page 3: ...tion circuit Even though this is a small amount it still presents a fire explosion hazard if it leaks out of refrig erant containing parts When mixed with air a flammable propane air mixture can be created and easily ignited by sparks open flames or hot surfaces This is particularly true in confined zones Propane is heavier than air and tends to settle at lower points To mitigate the risk please f...

Page 4: ...NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VA PORS AND LIQUIDS NEAR THIS OR ANY OTHER APPLIANCE DO NOT TOUCH COLD SURFACES WITH DAMP OR WET HANDS SKIN MAY STICK TO EXTREMELY COLD SURFACES DO NOT ALLOW CHILDREN TO CLIMB HANG OR STAND ON FREEZER SHELVES KEEP FINGERS OUT OF PINCH POINT AREAS DISCONNECT POWER TO THE UNIT PRIOR TO CLEANING OR REPAIRING BEFORE DISCARDING THIS OR ANY OTHER APPLIANCE RE...

Page 5: ... Controller Symbols and Functions Manual Defrost How to Remove the Front Bottom Grill Condenser Cleaning Cabinet Cleaning Interior LED Strip Replacement ISD Trans Light LED Panel Replacement ISD Trans Light LED Strip Replacement Graphic Panel Replacement Trans Light Troubleshooting Guide Parts List Illustration 20X UDGF Illustration 43X UDGF Wiring Diagram 1 2 2 2 3 4 5 6 6 7 7 8 8 9 9 10 11 12 13...

Page 6: ...orp s factory or repair facilities if the re pairs in the judgement of Minus Forty Technologies Corp have affected the reli ability or wear of the product and nor does the guarantee apply to any product which has been subject to misuse accident or to any product which has not been maintained pursuant to the instruction of Minus Forty Technologies Corp This warranty does not extend to any consequen...

Page 7: ...The warranty and liability does not cover damage resulting from excessive voltage variations The anti fog glass door has a protective film on the inner side After the unit has been installed peel and remove the protective film covering the inner glass surface WARNING These freezers MUST be installed on a dedicated grounded circuit protected with a 15 Amp circuit breaker or a 15 Amp time delay fuse...

Page 8: ...res disconnected at back of electronic control See actions described in the controller section pages 6 7 Evaporator fan does not run Fan wire disconnected Door switch not working Defrost probe not attached to the evaporator coil Check wiring Check door switch Check the location of defrost probe It should be pressed in between fins in the middle of the evaporator and close to the cabinet top WARNIN...

Page 9: ... receptacle Remove extension cords or other equipment on the same circuit Freezer not getting cold but compressor is operating Freezer located in direct sunlight or ambient room temperature is too hot Condenser clogged with dust Move freezer away from direct sunlight Room temperature is recommended not to exceed 86ºF 30ºC 55 RH See page 9 Cleaning Condensing unit operating for a prolonged period o...

Page 10: ...HT LED STRIP REPLACEMENT CONT D WARNING Make sure the freezer is disconnected from the power supply before any service Press the freezer switch to the Off position then unplug the power cord from electrical receptacle All service work must be conducted by a certified technician only Slide out the old panel and replace with the new panel Plug the freezer in and make sure the light switch on the bot...

Page 11: ... 1 Press and release P button the set temperature and SP1 are displayed alternatively on the controller 2 Press the UP or DOWN buttons to adjust the set temperature 3 Press P to store the adjusted value The electronic control will return to cabinet temperature display The U Button on the electronic controller is used for displaying cabinet and defrost temperatures PR1 and PR2 parameters 1 POWER sw...

Page 12: ...ted by a certified technician only LED PANEL LED PANEL L E D P A N E L EXTRUSION DISPLAY LENS GRAPHIC PANEL DISPLAY LENS GRAPHIC PANEL ALUMINUM TAPE At the left side of the controller display are the following LED indicators CONTROLLER ALARMS AND SIGNALS CONT CONTROLLER SYMBOLS AND FUNCTIONS Message Cause Action StArt dELAy Start up delay in progress Wait for 6 minutes Hi F or Hi C Maximum tempera...

Page 13: ...d ice gradually builds up Excessive ice buildup reduces cooling performance and may cause the failure of refrigeration system and product loss Ice buildup may be noticed through the evaporator fan grill on the coil fins To perform a manual defrost follow these steps 1 Press the UP arrow button and hold it for 6 seconds 2 Wait until the electronic control stops defrost the Def LED dot flashes 3 If ...

Page 14: ...GENERAL The freezer should be cleaned at regular intervals to meet a good standard of hygiene and to keep the freezer attractive as an effective point of purchase display INTERIOR CLEANING Use only mild non abrasive liquid cleaner water and a soft cloth for the entire freezer interior Make sure to wipe off all residue EXTERIOR CLEANING Use only mild non abrasive liquid cleaner water and a soft clo...