background image

11

12

ITEM(S) NEEDED

#12 x 1

ad.  Once the Splicers are secure on both wires, take the 

Shrink Tubes and slide them over the Splicers. The 
Shrink Tubes should be centered over the Splicer 
and completely cover the wire connections.

Minn Kota Consumer & Technical Service 
Johnson Outdoors Marine Electronics, Inc. 
PO Box 8129 
Mankato, MN  56001

121 Power Drive 
Mankato, MN 56001 
Phone (800) 227-6433 
Fax (800) 527-4464

minnkotamotors.com

©2019 Johnson Outdoors Marine Electronics, Inc.  

All rights reserved.  

Part #2377118

Rev C 

12/19

ECN 40131

For warranty information, please visit 

minnkotamotors.com

.

11ad

11ae

Plug Assembly

Plug Assembly

Splice Cover

Shrink Tube

Positive Power 

Lead (+)

Negative Power 

Lead (-)

Negative (-)

Power Lead 

Splicer

Splicer

Splicer

Shrink Tube

Shrink 

Tube

Shrink 

Tube

11ac

#6 x 1

ab.  The Splicer and Shrink Tube should be added to the 

Plug Receptacle so it can be attached to the Boat 
Wires. Take the Plug Receptacle (Item #B) and place 
one Shrink Tube (Item #6), followed by one Splicer 
(Item #12) on the end of the black Negative (-) 
Wire of the Plug Receptacle. Secure the Splicer by 
tightening the Set Screw with a 3/32" Allen Wrench 
to 20 in-lbs. 

ac.  Take the Plug Assembly and identify the red Positive 

(+) Power Lead on the Plug Assembly and align 
it with the Positive (+) Power Lead on the Trolling 
Motor Wires. Insert it into the Splicer at the end of 
the Positive (+) Lead Wire from the Plug Assembly. 
Take the black Negative (-) Power Lead from the Plug 
Assembly and align it with the Negative (-) Power 
Lead from the Trolling Motor Wire. Insert it in the 
Splicer at the end of the black Negative (-) Power 
Lead of from the Trolling Motor Wires. Secure the Set 
Screw of both Splicers with the Allen Wrench.

NOTICE: 

The Shrink Tubes are meant to water 

proof the connection between the Plug Receptacle 
and the Boat Wires. Make sure there are no gaps 
around the wires that would allow water to reach the 
connection. 

NOTICE: 

When disconnecting the plug assembly 

from the receptacle, be sure to install and tighten the 
Dust Cap.  This will prevent water or debris intrusion.

Plug 

Assembly

Plug 

Assembly

11ab

Positive (+)

Power Lead

Positive (+) 

Power Lead

Negative (-) 

Power Lead

Trolling 

Motor Wires

ae.  When satisfied with the position, secure the Shrink 

Tubes in place with a Heat Gun. Then slide the 
Splice Cover over the Shrink Tubes to complete the 
installation. 

NOTICE: 

When connecting the plug assembly from 

the receptacle, be sure to tighten the Threaded Collar to 
ensure a proper water tight seal is achieved to protect 
electrical contacts.  Failure to tighten the Threaded Collar 
could result in water intrusion.

Threaded 

Collar

Summary of Contents for 1865128

Page 1: ...CK 4X6 4ML Clear 1 12 SPLICER 6 10 AWG TIN PLTD 4 14 2372950 FERRULE 6 AWG 47 TIN PLTD 2 16 2372951 FERRULE 8 AWG 47 TIN PLTD 8 18 2372952 FERRULE 10 AWG 47 TIN PLTD 2 20 2377117 INSTRUCTIONS TRLL MTR...

Page 2: ...ng Location 1 2 1b 1c 2d NOTICE The ends of the Boat Wires may have any sort of electrical connector that should be removed NOTICE For ease of installation it is recommended to stagger the ends of the...

Page 3: ...Negative Wire black Plug Receptacle Plug Receptacle NOTICE The 6 AWG Ferrule are the largest in the provided hardware The four 8 AWG Ferrules may only be needed if the Plug Receptacle or Plug Assembly...

Page 4: ...ntil the Plug Receptacle sits against the mounting surface 5k Shrink Tubes Plug Receptacle NOTICE The Shrink Tubes are meant to water proof the connection between the Plug Receptacle and the Boat Wire...

Page 5: ...mbly is in an acceptable location Check for clearance of other items on the mounting surface and if the cord will interfere with the operation of anything in the area r Once in an acceptable location...

Page 6: ...c shock 9x 9y Trolling Motor Wires Positive Power Lead Positive Power Lead Positive Power Lead Positive Power Lead Negative Power Lead Negative Power Lead Negative Power Lead Negative Power Lead Troll...

Page 7: ...ower Lead on the Plug Assembly and align it with the Positive Power Lead on the Trolling Motor Wires Insert it into the Splicer at the end of the Positive Lead Wire from the Plug Assembly Take the bla...

Page 8: ...il du temps et cr er une mauvaise connexion Des mauvaises connexions pourraient causer un court circuit ou un risque extr me d incendie Suivez les instructions d installation fournies pour viter une d...

Page 9: ...le 1 2 1b 1c 2d AVIS Les extr mit s des fils du bateau peuvent pr senter tout type de connecteur lectrique qui doit tre retir AVIS Pour faciliter l installation nous vous recommandons de d caler les e...

Page 10: ...il n gatif noir Fil n gatif noir Prise de fiche Prise de fiche AVIS La virole de calibre 6 AWG est la plus grande de la quincaillerie fournie Les quatre viroles de calibre 8 AWG peuvent tre requises s...

Page 11: ...ns le trou perc de mani re ce que la prise de fiche repose contre la surface de montage 5k Gaines thermor tr cissables Prise de fiche AVIS Les gaines thermor tr cissables visent rendre tanche la conne...

Page 12: ...un bon emplacement V rifiez le d gagement des autres articles sur la surface de montage et si le cordon risque de nuire au fonctionnement de tout l ment dans la zone r Lorsque vous tes dans un emplace...

Page 13: ...mentation positif C ble d alimentation positif C ble d alimentation positif C ble d alimentation n gatif C ble d alimentation n gatif C ble d alimentation n gatif C ble d alimentation n gatif Fils du...

Page 14: ...d alimentation positif rouge dessus puis alignez le sur le c ble d alimentation positif des fils du moteur de p che la tra ne Ins rez le dans l pisseur l extr mit du fil conducteur positif de l ensem...

Reviews: