background image

INSTRUCTION MANUAL WARRANTY CERTIFICATE

SUPRA 32

BY

U.S. Patent: D450,830

Summary of Contents for SUPRA 32

Page 1: ...INSTRUCTION MANUAL WARRANTY CERTIFICATE SUPRA 32 BY U S Patent D450 830...

Page 2: ...nited States Federal and or State Law including Patent Trademark and or Copyright laws Manual design and all elements of manual design are protected by U S Federal and or State Law including Patent Tr...

Page 3: ...arranty service the owner should return the fan along with proof of purchase to a Minka Aire authorized dealer The Minka Aire authorized dealer shall then at its sole discretion repair the fan replace...

Page 4: ...costs This limited warranty is in lieu of all other express warranties This limited warranty excludes all incidental and consequential damages and Minka Aire shall not under any circumstances be liab...

Page 5: ...NS FINISHING THE INSTALLATION ATTACHING THE FAN BLADES ATTACHING THE SWITCH CUP OPERATING YOUR FAN CARE OF YOUR FAN TROUBLESHOOTING SPECIFICATIONS 1 2 3 4 5 6 7 8 9 10 11 12 UL LISTED E75795 R 1151 W...

Page 6: ...l 5 If you are mounting the fan to a ceiling fan outlet box use a U L Listed metal octagonal outlet box marked Acceptable for Fan Support Secure the box directly to the building structure The outlet b...

Page 7: ...OF FIRE ELECTRIC SHOCK OR OTHER PERSONAL INJURY MOUNT FAN ONLY TO A U L LISTED OUTLET BOX OR SUPPORTING SYSTEM MARKED ACCEPTABLE FOR FAN SUPPORT AND USE MOUNTING SCREWS PROVIDED WITH THE OUTLET BOX I...

Page 8: ...hardware 10 X 1 5 Wood screws 2 PCs 10 X 3 4 Machine screws 2PCs Lock washers 2 PCs 4mm star washers 2 PCs Wire nuts 3 PCs Washers 2 PCs B Blade attachment hardware 3 16 x 7 5mm screws 19 PCs Fiber wa...

Page 9: ...astic outlet box Figure 1 2 and 3 are examples of different ways to mount the outlet box Note You may need a longer downrod to maintain proper blade clearance when installing on a steep sloped ceiling...

Page 10: ...tor Assembly Fig 6 Step 3 Remove the Hanger Ball from the Downrod Assembly by loosening the Set Screw and removing the Cross Pin Fig 7 Step 4 Carefully feed fan wires up through the downrod Fig 8 Thre...

Page 11: ...Y WIRES Fig 5 Fig 7 Fig 8 Fig 6 Fig 10 REGISTRATION SLOT CROSS PIN HANGER BALL DOWNROD HITCH PIN LOCK PIN SET SCREWS SET SCREW Fig 9 DOWNROD CANOPY SET SCREWS HITCH PIN LOCK PIN COUPLING OMIT COUPLING...

Page 12: ...und wire Green or Bare Copper connect the fan ground wires from hanger ball and hanger bracket to it otherwise con nect the fan ground wire wires from the hanger ball and hanger bracket to gether Fig...

Page 13: ...NTROL LIGHT KIT CONTROLLED BY LIGHT SWITCH WIRING OPTION 2 BLACK HOT WALL WHITE NEUTRAL GREEN GROUND CEILING HOUSE WIRE SUPPLY BLUE OPTIONAL LIGHT BLACK MOTOR WHITE NEUTRAL LIGHT SWITCH FAN WALL CONTR...

Page 14: ...e the canopy up to the ceiling and over the two screws on hanger bracket Rotate canopy clockwise until it stops tighten screws Fig 14 Fig 14 OUTLET BOX HANGER BRACKET HANGER BALL CANOPY FINISHING THE...

Page 15: ...curely Fig 15 Step 2 Remove rubber stops from motor Rotate motor so that the screw holes are revealed through the opening on switch cap plate Align motor holes to blade holders and secure with screws...

Page 16: ...against plate and rotate it until the screw holes are aligned Secure switch cup to plate using the screws removed earlier Fig 17 NOTE DO NOT PINCH WIRES BETWEEN THE SWITCH HOUSING AND THE SWITCH CUP P...

Page 17: ...fan to stop before changing thesettingoftheslideswitch Warmweather Forward A downward airflow creates a cooling effect as shown in Fig 18 This allows you to set your air conditioner on a warmer settin...

Page 18: ...Fig 18 Fig 19 SUMMER OPERATION WINTER OPERATION...

Page 19: ...or wood blades or possibly cause an electrical shock 3 If your fan is provided with wood veneer blades you can apply a light coat of furniture polish for additional protection and enhanced beauty Cove...

Page 20: ...time Make sure all motor housing screws are snug Make sure the screws that attach the fan blade bracket to the motor hub are tight Some fan motors are sensitive to signa ls from solid state variable...

Page 21: ...ings Your actual fan may vary They do not include amps and wattage used by the light s 0 22 0 39 0 53 95 181 262 1191 3114 5061 9 30 65 6 9 kgs 7 67 kgs 1 05 RPM CFM N W G W C F 32 120 120 120 Fan Siz...

Reviews: