SYMPTOM
Frequency Interference
SOLUTION
1.Turn the power off to your ceiling fan.
2.Please use a small size tool to change the frequency settings on the control system.
3.Returm power to the unit.
Note: After the AC power is on, do not press any other button on the transmitter before pressing the “Stop” button, doing so will cause the procedure to fail.
4.Within 60 seconds of turning the fan’s AC power ON. Press the transmitter’s “Stop” button and hold the “Stop” button for 10 seconds.
5.Once the receiver has detected the set frequency, the down light of your fan if applicable will blink twice.(there is no indication if your fan is not equipped
with a light).
6.The receiver has now learn the frequency which has been selected on the transmitter. After completing the steps above, you should be able to operate the
ceiling fan and light. If the fan is not responding to the transmitter. please turn the power off to the receiver, and repeat the process.
Summary of Contents for Minka Aire Sabot
Page 1: ...CERTIFICATE S a b o t ...
Page 16: ...8 OPERATING THE REMOTE CONTROL WALL CONTROL cool ...
Page 19: ...9 CARE OF YOUR FAN ...
Page 24: ...1635 2566 3396 4221 4918 5779 2 7 4 6 7 6 12 7 20 0 33 0 606 558 447 332 246 175 ...
Page 25: ...S a b o t MANUAL DE INSTRUCCIONES CERTIFICADO DE GARANTIA ...
Page 33: ...3 18 ...
Page 35: ...5 ...
Page 36: ...CUBIERTA DE DOSEL Fig 9 Fig 10 Fig 11 Fig 12 ...
Page 40: ...8 ...
Page 43: ...9 ...
Page 44: ...10 ...
Page 45: ......
Page 46: ......