8

7

Operating your Minivator Simplicity

+

950

Operating the swivel

Figure 10

A swivel seat is provided to enable you to
mount/dismount the seat more easily at
the top of the stairs by swivelling you on to
the landing.

To operate the seat swivel, wait until
the stairlift has stopped.

To swivel the seat hold either (there is one
both sides of the seat) swivel lever down
or pull it up. This will release the seat lock
and allow you to move the seat round by
pushing away from the footplate. When
the seat reaches 90 degrees it will lock in
position.

You should not attempt to leave the seat
until it has firmly ‘clicked’ into its locked
position.

To swivel in the opposite direction follow
the same procedure, but push away from
the landing.

Power operated swivel (optional)

If your stairlift is fitted with an optional
power operated swivel there will be no
swivel levers fitted. In order to swivel the
seat hold the operating toggle in the up
direction. When the stairlift reaches the
top of the stairs continue to hold the
operating toggle in the up direction.
The stairlift will beep three times and then
the seat will swivel. When the seat
is fully swivelled to 90 degrees the seat will
stop.

You should not attempt to leave the seat
until it is fully rotated.

To swivel in the opposite direction follow
the same procedure in reverse. Push the
operating lever in the down direction. The
seat will beep three times and then after a
short pause it will rotate to the driving
position. Continue to hold the operating
lever in the down direction. The stairlift
will then again beep three times before
beginning its descent.

SAFETY PRECAUTIONS

NEVER

Swivel the seat without the lap belt
fastened.

NEVER

Mount or dismount the swivel seat unless it
is locked in position.

NEVER

Try to operate the swivel seat whilst the
stairlift is in motion. (As a safety precaution,
should you try to use it whilst the lift is in
motion, it will cause the lift to stop).

NEVER

Attempt to travel up or down the staircase
unless the seat is in the correct position (i.e.
facing directly across the staircase).

Operating your Minivator Simplicity

+

950

In the unlikely event that the lift has a
total power failure or runs on to the final
track stops there is an emergency hand
winding procedure. Please follow these
steps:

1. Switch off the stairlift with the key.

2. Insert the emergency hand winding

knob (Figure 11).

3. Turn the knob in the direction indicated

for the required movement.

4. When the desired position is reached

remove the hand winder and switch the
lift on.

If in any doubt contact your local
Minivator approved dealer or ring
Minivator direct on 08700 118282.

Your stairlift is fitted with safety edges
on the bottom of the footrest and on the
lift itself that will stop the stairlift should
any article become trapped by the footrest
(Figure 12).

To remove the article reverse the stairlift
away from the object then have the object
removed from the staircase. Proceed on
your stairlift as normal.

Emergency hand

winding instructions

Trapped articles

Figure 11

Figure 12

E

N

G

L

IS

H

Summary of Contents for Simplicity 950 Series

Page 1: ...nue Pensnett Estate Kingswinford West Midlands DY6 7FJ England User support 0870 118282 International Desk 44 0 1384 275736 Email sales minivator co uk www minivator co uk North America Sterling Stair...

Page 2: ...BS5776 1996 as well as ISO 9386 2 They also carry the CE mark Minivator are audited regularly to ensure we continue to conform to ISO 9001 and this provides you with the assurance of using a high qua...

Page 3: ...m home for a long period and decide to switch off the mains supply it is important that you also switch off the lift from this on off switch This will ensure that the lift batteries will remain charge...

Page 4: ...he seat squab it will automatically fold away the footplate when the front seat squab is lifted It will also lower the footplate when the front seat squab is lowered Power footplate link arm operated...

Page 5: ...short pause it will rotate to the driving position Continue to hold the operating lever in the down direction The stairlift will then again beep three times before beginning its descent SAFETY PRECAUT...

Page 6: ...Your stairlift track is fitted with charging points normally at the top and bottom of the staircase Your stairlift should be left on one of these charging points when not in use to ensure that the bat...

Page 7: ...ivator Code 8 Meaning Shows when toggle switch is activated in up down direction Self help action N A 8 A Code b Meaning A switch is active at power on i e Toggle Up Toggle Down IR Up IR Down or Learn...

Page 8: ...INGE ENABLE FAST RAMP UNUSED ON 1 2 3 4 1 1 1 2 3 4 5 6 1 2 3 4 5 6 COMMON CHASSIS BOTTOM EDGE CHASSIS UNDERPAN FOOTPLATE TO CHASSIS CONNECTOR CHASSIS TOP EDGE SEAT TO CHASSIS CONNECTOR TO SEAT CONNEC...

Page 9: ...EED DOWN PING DISABLE PLATFORM DISABLE HINGE DISBLE LEFT HAND LIFT SLOW RAMP UNUSED FULL SPEED UP FULL SPEED DOWN PING ENABLE PLATFORM ENABLE HINGE ENABLE RIGHT HAND LIFT FAST RAMP UNUSED xAppendix 3...

Page 10: ...17 Important information about your stairlift which should be completed by the installation engineer Installed by Company Name Serial No Date of installation First service due Dealer Stamp 18 ENGLISH...

Page 11: ...reppenlifte werden gem der Britischen Standards f r Treppenlifte BS5776 1996 und ISO 9386 2 gebaut und getestet Sie tragen auch das CE Pr fsiegel Minivator Produkte werden fortw hrend auf dem ISO 9001...

Page 12: ...ies angezeigt wird Wenn Sie f r l ngere Zeit aus dem Haus gehen und die Hauptstromversorgung abschalten ist es wichtig dass Sie den Lift mit dem Hauptschalter ausschalten Auf diese Art bleiben die Lif...

Page 13: ...zenautomatik an der Sitzlehne ausgestattet ist klappt die Fu st tze automatisch weg wenn die Sitzr ckenlehne angehoben wird Beim Absenken der Sitzr ckenlehne wird auch die Fu st tze ausgeklappt Fu st...

Page 14: ...r kurzen Pause in die Fahrtrichtung Halten Sie den Hebel weiter nach unten Der Treppenlift piepst erneut dreimal bevor er herunterf hrt SICHERHEITSHINWEISE NIEMALS Den Sitz ohne Sitzgurt drehen NIEMAL...

Page 15: ...estattet oben und unten an der Treppe Der Treppenlift muss bei Nichtbenutzung an einer dieser Stellen parkiert werden um aufzuladen Wenn er ein Piepger usch macht und oder eine 2 auf der Pr fanzeige a...

Page 16: ...Anzeige f r Hebel abw rts aufw rts Selbsthilfema nahme N A 8 A Code b Bedeutung Schalter ist aktiv Selbsthilfema nahme Ihren H ndler oder Minivator verst ndigen Code C Bedeutung Die IR Adresse Wippsch...

Page 17: ...AUTOMATISCHE KLAPPSCHIENE EINGESCHALTET RAMPE SCHNELL NICHT BELEGT EIN 1 2 3 4 1 1 1 2 3 4 5 6 1 2 3 4 5 6 H UFIG M F STECKVERBINDUNG SCHL SSEL MULTI PIN ANSCHLUSS ALLE SICHERHEITSSCHALTKREISE SOLLTE...

Page 18: ...GKEIT AUFW RTS HALBE GESCHWINDIGKEIT ABWARTS PING AUSGESCHALTET PLATTFORM AUSGESCHALTET KLAPPSCHIENE AUSGESCHALTET LIFT LINKS RAMPE LANGSAM UNBELEGT VOLLE GESCHWINDIGKEIT AUFW RTS VOLLE GESCHWINDIGKEI...

Page 19: ...35 Wichtige Information ber Ihren Treppenlift die Ihr Monteur ausf llen sollte Montiert von Firma Name Serien Nr Datum der Montage Erster Kundendienst Stempel H ndler 36...

Page 20: ...l ISO9386 2 Ils portent galement la mention CE Minivator est r guli rement audit pour nous assurez que nous continuons tre conforme l ISO 9001 ce qui vous garantit une grande qualit et un produit de...

Page 21: ...riode et que vous d cidiez de couper l alimentation il est important que vous mettiez galement ce bouton sur la position Arr t off Cela assurera le maintien de la charge de la batterie du monte escal...

Page 22: ...ussin du si ge de devant est soulev Il va galement s abaisser lorsque le coussin du si ge de devant est abaiss Liaison du plateau des pieds lectrique actionn e par l accoudoir optionnel Si votre monte...

Page 23: ...trajet Continuez de maintenir le levier vers le bas Le monte escaliers va nouveau mettre trois bip avant de commencer sa descente PRECAUTIONS DE SECURITE NE JAMAIS Faire pivoter le si ge sans avoir at...

Page 24: ...aliers Votre rail de monte escaliers a des points de charge Normalement en haut et en bas de la cage d escaliers Votre monte escaliiers doit tre laiss sur un de ces points de chargement lorsqu il n es...

Page 25: ...cation Affich quand l interrupteur est activ sur direction haut bas Faites vous m me N A 8 A Code b Signification Un interrupteur est actif alimen en marche c d Interrupteur haut bas T l commande haut...

Page 26: ...BAS PING ACTIVEE PLAT ACTIVEE ARTICULATION ACTIVEE RAMPE RAPIDE INUTILSE MARCHE 1 2 3 4 1 1 1 2 3 4 5 6 1 2 3 4 5 6 COMMUN BORD DU BAS DU CHASSIS PAN DE DESSOUS DU CHASSIS CONNECTEUR DU REPOSE PIED AU...

Page 27: ...ESSE VERS LE HAUT VITESSE MOYENNE BAS PING DESACTIVE PLAT DESACTIVE ARTICULATION DESACTIVEE MONTE ESCALIERS COTE GAUCHE RAMPE LENTE INUTILISE PLEINE VITESSE VERS LE HAUT PLEINE VITESSE BAS PLAT ACTIVE...

Page 28: ...importantes au sujet de votre monte escaliers qui doivent tre remplies par le technicien d installation Install par Nom de la soci t N de s rie Date d installation Premier service due Tampon du vende...

Page 29: ...CE Los Minivator reciben regularmente una auditor a para garantizar que siempre cumplimos con ISO 9001 y esto le brinda a usted la seguridad de que usamos un producto de alta calidad y bien fabricado...

Page 30: ...de casa por un largo per odo de tiempo y decide apagar la alimentaci n principal es importante que tambi n apague elevador desde este interruptor de on off Esto asegurar que las bater as del elevador...

Page 31: ...ede operarse desde el coj n del asiento plegar autom ticamente el reposapi s cuando se levante el coj n del asiento delantero Tambi n bajar el reposapi s cuando el coj n del asiento delantero se baje...

Page 32: ...go de una corta pausa empezar a rotar a la direcci n deseado Contin e sosteniendo la palanca de operaci n en direcci n hacia abajo El subescaleras volver a dar tres pitidos antes de descender PRECAUCI...

Page 33: ...os de carga normalmente en la parte superior e inferior de las escaleras Su subescaleras debe permanecer en uno de esos puntos de carga cuando no est en uso para asegurarse que las bater as se carguen...

Page 34: ...r de la palanca est activado en direcci n arriba abajo Acci n de auto ayuda N A 8 A Signif b C digo Interruptor A est activado en por ejemplo Palanca Arriba Palanca Abajo IR Arriba IR Abajo o Aprendiz...

Page 35: ...OMPLETA HACIA ABAJO ALARMA CONECTADA ACTIVAR PLATAFORMA AUTOM TICA ACTIVACI N DE BISAGRA AUTOM TICA RAMPA R PIDA SIN USO ON 1 2 3 4 1 1 1 2 3 4 5 6 1 2 3 4 5 6 15A FUSIBLE ULTRASENSIBLE COM N M F CONE...

Page 36: ...TIVARA EL MODO DE OSCILACI N EL CTRICA CONECTADO 1 2 3 4 VELOCIDAD MEDIA ARRIBA VELOCIDAD MEDIA ENCENDIDA DESCONEXI N DE LA ALARMA DESCONEXI N DE LA PLATAFORMA COLECTOR DESCONECTADO ELEVADOR EN LA MAN...

Page 37: ...ante con respecto a su silla elevadora que debe completarse por el ingeniero de instalaci n Instalado por Nombre de la Compa a No de Serie Fecha de instalaci n Primer mantenimiento vence Sello del Dis...

Page 38: ...marchio CE Minivator viene controllata regolarmente per garantire la continua conformit ISO 9001 ci garantisce ai nostri clienti un alta qualit e un elevatore prodotto con precisione Introduzione 73...

Page 39: ...decidete di spegnere l alimentazone generale importante ricordarsi di spegnere quest interruttore Questo garantir che le batterie rimangano cariche durante la vostra assenza Cose da fare prima dell u...

Page 40: ...to azionato dal cuscio del sedile la pedana si ripiegher automaticamente quando il cuscino del sedile viene sollevato La pedana si abbasser quando il cuscino anteriore del sedile verr abbassato Colleg...

Page 41: ...e produrr nuovamente tre suoni bip prima di iniziare la discesa PRECAUZIONI PER LA SICUREZZA MAI far ruotare il sedile senza la cintura di sicurezza allacciata MAI salire o scendere dal sedile rotante...

Page 42: ...vrebbe essere lasciato in sosta in uno di questi due punti di caricamento quando non in uso in modo che le batterie vengano caricate Se l elevatore produce un suono bip continuo e o lo schermo diagnos...

Page 43: ...leva attivata in direzione su gi Auto aiuto Non disponibile 8 A Codice b Significato Uno degli interruttori attivo per esempio leva su leva gi IR su IR gi Auto aiuto Contattare il vostro rivenditore...

Page 44: ...ABILITAZIONE PING ATTIVA PEDANA AUTOMATICO ATTIVA RIBALTAMENTO AUTOMATICO RAMPA VELOCE NON USATA ON 1 2 3 4 1 1 1 2 3 4 5 6 1 2 3 4 5 6 VIOLA DI TIPO COMUNE LIMITE INFERIORE DELLA STRUTTURA SOTTOCOPPA...

Page 45: ...ING DISABILITAZIONE PLAT DISABILITAZIONE CARDINE MONTASCALE LATO SINISTRO RAMPA LENTA NON USATA ACCELERAZIONE PIENA DISCESA MAX VELOCITA ABILITAZIONE PING ABILITAZIONE PLAT ABILITAZIONE CARDINE MONTAS...

Page 46: ...l montascale che vanno completate a cura del tecnico che effettua l installazione Installato da Ragione Sociale Numero di Serie Data di installazione Primo intervento di manutenzione previsto il Timbr...

Reviews: