1.  The water purifier is intended for indoor use only. The water purifier is designed to mount horizontally. The water purifier 

should be protected from the elements and from temperatures below freezing. The ambient temperature, in the area 
surrounding the water purifier, should be between 35

o

 F and 100

o

 F.

2.  Electrical power supplied to the water purifier 

MUST

 match power requirements listed on the water purifier. Use of a voltage 

surge protector is recommended.

3. 

 

 

Install water purifier within 48” of a known good ground. Water Purifier will need to be installed 

into approved ground fault circuit interrupt (GFCI) receptacle.  Where a 2-prong or unprotected 3-prong receptacle is 
encountered, it must be replaced by a properly grounded Ground Fault Circuit Interrupt (GFCI) receptacle. Installation must 
be in accordance with the National Electrical Code and any local codes and ordinances by a qualified electrician.

4.  The water purifier should be located in a dry, well-lit area, which provides enough room to perform routine maintenance.  

This includes a minimum distance of one chamber length from the chamber end, to allow for cleaning and/or the  
changing of the lamp and quartz sleeve as well as a minimum of 6” on the opposite end of the water purifier. Minimum 
clearance to floor 18’’.

5.  The water purifier should always be located closest to the point of use. This reduces the chance of the purified water being 

re-contaminated by bacteria in the water distribution system after the water purifier.

6. 

  As with any water handling device, the water purifier should be located in an area where any possible 

condensation or leakage from the water purifier, any purifier accessory and/or plumbing will not result in damage to the area 
surrounding the water purifier.

 For added protection, it is recommended that a suitable drain pan be installed under 

the purifier. The drain pan must be plumbed to an adequate, free flowing drain to prevent water damage in event of 
a leak. There are numerous leak detection/flood stop devices, available on the market today, designed to stop flow 
of water, reducing the chance of water damage due to leakage. For more details regarding leak prevention and/or 
limiting damages due to leaks please contact factory.

7.  The water purifier should be located after all other water devices, such as De-ionizers, Water Softeners, Carbon Filters, 

Pre-Filters, Reverse Osmosis, Pressure Tanks, and Pumps. This elimates the possibility of the purified water being re-
contaminated by bacteria in any of these units.

r

eCommended

 i

nstallation

Figure 1 - Recommended Installation

Incoming

Water

Supply

COMMON

PRE-TREATMENT or

PUMPING DEVICES

1. Deionizer

2. Water Softener

3. Carbon Filters (GAC)

4. Pressure Tank

5. Pump

6. Reverse Osmosis

7. Prefilters

Cold Water Line

Ultraviolet Water Purifiers 

should be installed closest 

to the point of use. (POU)

5 Micron

   Filter

Valve

Union

Elbow

Elbow

OPTIONAL EQUIPMENT

Flow Control Valve

POINT OF USE (POU)

Ultraviolet Water Purifiers 

should be installed closest 

to the point of use. 

Ultraviolet 

Water Purifier

Outlet Line to point of use 

to be as short as possible

Recommended Minimum

Clearance for Lamp or 

Quartz Sleeve Removal

Union

Valve

OPTIONAL EQUIPMENT

 Mounting Kit

 

Model 

DIM. "X" 

  MIN 1 

10 

3

/

8

  MIN 1.5  14 

15

/

16

"

  MIN 3 

12 

7

/

8

"

  MIN 6 

22"

  MIN 9 

29"

Use of Metal Pipe is

recommended for 12"

past elbow to the inlet 

or from the outlet.

(avoids ultraviolet degradation 

of exposed plastic pipe)

22"

120v 50/60Hz using ballast no. 10-0508B has a 
ground wire attached.
230v 50/60Hz using ballast no. 10-0504B has a 
ground wire attached.
      

Note: Drain Pan 
Recommended. Water 
purifier should be installed at 
minimum of 18” above floor

Note: Use of metal pipe is recommended for 
connection to both the purifier inlet and outlet 12” 
past the first elbow. (avoids ultraviolet degradation 
of exposed plastic pipe)

Summary of Contents for MIN-6

Page 1: ...2017 Atlantic Ultraviolet Corporation ASSEMBLED IN THE USA Installation Operation Maintenance Read and Follow All Safety Instructions Save These Instructions Models Ballast 120v 50 60 Hz Ballast 230v 50 60Hz MIN 6 10 0508B 10 0504B MIN 9 10 0508B 10 0504B Owner s Manual Owner s Manual ULTRAVIOLET WATER PURIFIERS ...

Page 2: ...lieved to be correct However no guarantee or warranty of any kind expressed or implied is made with respect to the information contained herein Specifications and information are subject to change without notice SAFETY WARNINGS 3 SAFETY INSTRUCTIONS 3 SAFETY LABELING 3 CAUTION 3 PRODUCT APPLICATION 4 Construction 4 Principle of Operation 4 Limitation of Use 4 Water Quality 4 INSTALLATION 5 Locatio...

Page 3: ...ot avoided COULD result in death or serious injury This symbol pictorial is used to identify the need to wear approved ultraviolet blocking eyewear This symbol pictorial is used to identify the need to wear approved ultraviolet blocking face shield This symbol pictorial is used to identify components which must not be disposed of in trash Danger indicates an IMMINENTLY hazardous situation which if...

Page 4: ...z sleeve and the chamber wall Suspended microorganisms are exposed to the ultraviolet rays emitted by the germicidal lamp The LED indicator light located on the ballast provides visual indication of germicidal lamp operation Water leaving the purifier is instantly ready for use no further contact time is required Limitation of Use The water purifier is intended for the use with visually clear wate...

Page 5: ...will not result in damage to the area surrounding the water purifier For added protection it is recommended that a suitable drain pan be installed under the purifier The drain pan must be plumbed to an adequate free flowing drain to prevent water damage in event of a leak There are numerous leak detection flood stop devices available on the market today designed to stop flow of water reducing the ...

Page 6: ...ble 2 MIN 6 and MIN 9 Dimensional Data Model A B C D E F Inlet Outlet MIN 6 14 3 4 22 17 32 5 3 4 4 1 4 22 5 3 8 3 4 m NPT MIN 9 21 7 8 29 17 32 5 3 4 4 1 4 29 5 3 8 3 4 m NPT All specifications dimensional data etc are approximate and subject to change without notice ...

Page 7: ... entering the water purifier Particulates may cause damage to the quartz sleeve as well as interfere with the purifier s ability to disinfect the water The sediment filter may also help to reduce the amount of routine cleanings of the quartz sleeve 6 Shut off valves should be installed on both the inlet and outlet sides of the water purifier The use of bypass valves is not recommended The shut off...

Page 8: ... Safety Sensor alerts the user to any malfunction detected 3 PromateTM Time Delay Mechanism Provides a 2 minute warm up period during which the ultraviolet lamp achieves its full germicidal output before the water is allowed to flow through the water purifier The time delay mechanism is used in conjunction with and is electrically connected to the Solenoid Valve 4 PromateTM Solenoid Valve Operated...

Page 9: ...rovides visual indication of germicidal lamp operation This provides an indication of lamp operation and does not indicate the level of ultraviolet intensity or transmission through the water Ballasts have a built in audio alarm which will indicate lamp failure On purifiers so equipped the SENTRYTM Safety Sensor provides visual indication of ballast and ultraviolet lamp operation 2 To ensure prope...

Page 10: ...hamber Be sure to withdraw lamp straight out without angling until completely clear of quartz sleeve Lamp and quartz sleeve are easily damaged Exercise care when handling 5 Reinstall lamp in reverse order Germicidal ultraviolet rays are harmful to eyes and skin Do not restore power to water purifier until lamp and both EASY OFFTM End Caps have been properly reinstalled Step 1 Disconnect Power to W...

Page 11: ...e quartz sleeve from chamber NOTE It is advisable to support the quartz sleeve on the opposite end with your finger so that it does not drop to the bottom of the chamber as it slides into the chamber 7 Once the quartz sleeve is removed clean with alcohol or a mild non abrasive detergent Stubborn stains usually can be removed with a dilute hydrochloric acid NOTE Follow all manufacturer s instructio...

Page 12: ... quartz sleeve parallel to the chamber angling the quartz sleeve in any direction could result in the breakage of the quartz sleeve 11 As the quartz sleeve nears the far end of the chamber support the quartz sleeve by inserting your finger through the far end gland fitting and into the quartz sleeve This will minimize the possibility of breaking the quartz sleeve as it passes through the gland fit...

Page 13: ...amp as it nears its end of life EOL See Lamp Installation or Replacement in the Maintenance section Germicidal lamp not functioning Replace lamp See Lamp Installation or Replacement in the Maintenance section Low input voltage Verify input voltage to purifier Change in water quality Have water tested to confirm that it does not exceed maximum recommended concentration levels for use with this puri...

Page 14: ...tional WARNINGS 12volt and 24volt Direct Current DC ballasts and units Many Individuals regard ballasts and units powered by 12volt and 24volt Direct Current DC to be relatively benign from a safety standpoint However a DC ballast in order to operate an ultraviolet discharge lamp must produce an output as high as 600volts This voltage is high enough to produce a very serious or even lethal electri...

Page 15: ... 1 10 0508B 10 0508B 1B SteadfastTM Lamp Socket SureliteTM Ballast 230v 50 60Hz 1 10 0504B 10 0504B 2 Rubber O Ring Static Gland 2 00 1108B 00 1108B 3 STER L RAY Lamp 1 05 1370 R 05 0097A 4 Static Gland Nut 2 25 1492D 25 1492D 5 Teflon Washer 2 25 1235A 25 1235A 6 Rubber O Ring Quartz Sleeve 2 00 1238A 00 1238A 7 CRYSTAL CLEARTM Quartz Sleeve 1 15 1112A 15 1006A3 8 EASY OFFTM End Cap no hole 1 25 ...

Page 16: ... will be free from defects in material and workmanship for a period of one year from the date of shipment thereof or the product s total rated life whichever first occurs Within the warranty period we shall repair or replace such products which are returned to us with shipping charges prepaid and which are determined by us to be defective This warranty will not apply to any product which has been ...

Reviews: