background image

4

PRODUCT APPLICATION

C

onstruCtion

• 

The water purifier is designed to mount horizontally. 

• 

The water purifier’s chamber is passivated and electropolished type 304 Stainless Steel.

•  EASY-OFF

TM

 End Caps enable quick and easy lamp change, without disconnecting from the water supply or draining the 

purifier. No tools are required. 

Always disconnect electrical power when changing lamp.

P

rinCiPle

 

of

 o

Peration

The 

MINIPURE

® 

design has been carefully conceived to provide adequate germicidal dosage throughout the disinfection 

chamber. The dosage, as it applies to ultraviolet disinfection, is a function of time and the intensity of ultraviolet radiation to 
which the water is exposed. The exposure time, in seconds, is the total time it takes the water to flow through the disinfection 
chamber exposing it to the germicidal lamp. Exposure time is related to the flow rate; the higher the flow rate, the lower the 
exposure time or the lower the flow rate, the higher the exposure time. The ultraviolet intensity is the amount of energy, per unit 
time, emitted by the germicidal lamp. The dosage is the product of ultraviolet intensity and the exposure time. The operation of 
the 

MINIPURE

®

  is as follows:

• 

Water enters the purifier and flows into the annular space between the quartz sleeve and the chamber wall.

• 

Suspended microorganisms are exposed to the ultraviolet rays emitted by the germicidal lamp.

• 

The LED indicator light, located on the ballast, provides visual indication of germicidal lamp operation.

• 

Water leaving the purifier is instantly ready for use, no further contact time is required.

l

imitation

 

of

 u

se

The water purifier is intended for the use with visually clear water, not colored, cloudy or turbid. See 

“Water Quality”

 section 

below. The water purifier is 

NOT

 intended for the treatment of water that has an obvious contamination or intentional source, 

such as raw sewage; nor is the unit intended to convert wastewater to microbiologically safe drinking water.

W

ater

 Q

uality

Water quality plays a major role in the transmission of germicidal ultraviolet rays. It is recommended that the water does not 
exceed the following maximum concentration levels:

Table 1 - Maximum Concentration Levels

Turbidity

< 1 NTU

Manganese

0.05 mg/1

Total Suspended Solids

10 mg /1

pH:

6.5 - 9.5

Color:

None

Hardness

6 GPG or 102.6 PPM

Iron

0.3 mg/1

Tannins:

< 0.1 ppm (0.1 mg/l)

UV Transmission

>85% per cm*

* Contact Factory for recommendations on applications where UV transmission is < 85%

Effectively treating water with higher concentration levels than listed above can be accomplished, but may require added 
measures to improve water quality to treatable levels. If, for any reason, it is believed the ultraviolet transmission is not 
satisfactory, contact the factory.

Summary of Contents for MIN-6

Page 1: ...2017 Atlantic Ultraviolet Corporation ASSEMBLED IN THE USA Installation Operation Maintenance Read and Follow All Safety Instructions Save These Instructions Models Ballast 120v 50 60 Hz Ballast 230v 50 60Hz MIN 6 10 0508B 10 0504B MIN 9 10 0508B 10 0504B Owner s Manual Owner s Manual ULTRAVIOLET WATER PURIFIERS ...

Page 2: ...lieved to be correct However no guarantee or warranty of any kind expressed or implied is made with respect to the information contained herein Specifications and information are subject to change without notice SAFETY WARNINGS 3 SAFETY INSTRUCTIONS 3 SAFETY LABELING 3 CAUTION 3 PRODUCT APPLICATION 4 Construction 4 Principle of Operation 4 Limitation of Use 4 Water Quality 4 INSTALLATION 5 Locatio...

Page 3: ...ot avoided COULD result in death or serious injury This symbol pictorial is used to identify the need to wear approved ultraviolet blocking eyewear This symbol pictorial is used to identify the need to wear approved ultraviolet blocking face shield This symbol pictorial is used to identify components which must not be disposed of in trash Danger indicates an IMMINENTLY hazardous situation which if...

Page 4: ...z sleeve and the chamber wall Suspended microorganisms are exposed to the ultraviolet rays emitted by the germicidal lamp The LED indicator light located on the ballast provides visual indication of germicidal lamp operation Water leaving the purifier is instantly ready for use no further contact time is required Limitation of Use The water purifier is intended for the use with visually clear wate...

Page 5: ...will not result in damage to the area surrounding the water purifier For added protection it is recommended that a suitable drain pan be installed under the purifier The drain pan must be plumbed to an adequate free flowing drain to prevent water damage in event of a leak There are numerous leak detection flood stop devices available on the market today designed to stop flow of water reducing the ...

Page 6: ...ble 2 MIN 6 and MIN 9 Dimensional Data Model A B C D E F Inlet Outlet MIN 6 14 3 4 22 17 32 5 3 4 4 1 4 22 5 3 8 3 4 m NPT MIN 9 21 7 8 29 17 32 5 3 4 4 1 4 29 5 3 8 3 4 m NPT All specifications dimensional data etc are approximate and subject to change without notice ...

Page 7: ... entering the water purifier Particulates may cause damage to the quartz sleeve as well as interfere with the purifier s ability to disinfect the water The sediment filter may also help to reduce the amount of routine cleanings of the quartz sleeve 6 Shut off valves should be installed on both the inlet and outlet sides of the water purifier The use of bypass valves is not recommended The shut off...

Page 8: ... Safety Sensor alerts the user to any malfunction detected 3 PromateTM Time Delay Mechanism Provides a 2 minute warm up period during which the ultraviolet lamp achieves its full germicidal output before the water is allowed to flow through the water purifier The time delay mechanism is used in conjunction with and is electrically connected to the Solenoid Valve 4 PromateTM Solenoid Valve Operated...

Page 9: ...rovides visual indication of germicidal lamp operation This provides an indication of lamp operation and does not indicate the level of ultraviolet intensity or transmission through the water Ballasts have a built in audio alarm which will indicate lamp failure On purifiers so equipped the SENTRYTM Safety Sensor provides visual indication of ballast and ultraviolet lamp operation 2 To ensure prope...

Page 10: ...hamber Be sure to withdraw lamp straight out without angling until completely clear of quartz sleeve Lamp and quartz sleeve are easily damaged Exercise care when handling 5 Reinstall lamp in reverse order Germicidal ultraviolet rays are harmful to eyes and skin Do not restore power to water purifier until lamp and both EASY OFFTM End Caps have been properly reinstalled Step 1 Disconnect Power to W...

Page 11: ...e quartz sleeve from chamber NOTE It is advisable to support the quartz sleeve on the opposite end with your finger so that it does not drop to the bottom of the chamber as it slides into the chamber 7 Once the quartz sleeve is removed clean with alcohol or a mild non abrasive detergent Stubborn stains usually can be removed with a dilute hydrochloric acid NOTE Follow all manufacturer s instructio...

Page 12: ... quartz sleeve parallel to the chamber angling the quartz sleeve in any direction could result in the breakage of the quartz sleeve 11 As the quartz sleeve nears the far end of the chamber support the quartz sleeve by inserting your finger through the far end gland fitting and into the quartz sleeve This will minimize the possibility of breaking the quartz sleeve as it passes through the gland fit...

Page 13: ...amp as it nears its end of life EOL See Lamp Installation or Replacement in the Maintenance section Germicidal lamp not functioning Replace lamp See Lamp Installation or Replacement in the Maintenance section Low input voltage Verify input voltage to purifier Change in water quality Have water tested to confirm that it does not exceed maximum recommended concentration levels for use with this puri...

Page 14: ...tional WARNINGS 12volt and 24volt Direct Current DC ballasts and units Many Individuals regard ballasts and units powered by 12volt and 24volt Direct Current DC to be relatively benign from a safety standpoint However a DC ballast in order to operate an ultraviolet discharge lamp must produce an output as high as 600volts This voltage is high enough to produce a very serious or even lethal electri...

Page 15: ... 1 10 0508B 10 0508B 1B SteadfastTM Lamp Socket SureliteTM Ballast 230v 50 60Hz 1 10 0504B 10 0504B 2 Rubber O Ring Static Gland 2 00 1108B 00 1108B 3 STER L RAY Lamp 1 05 1370 R 05 0097A 4 Static Gland Nut 2 25 1492D 25 1492D 5 Teflon Washer 2 25 1235A 25 1235A 6 Rubber O Ring Quartz Sleeve 2 00 1238A 00 1238A 7 CRYSTAL CLEARTM Quartz Sleeve 1 15 1112A 15 1006A3 8 EASY OFFTM End Cap no hole 1 25 ...

Page 16: ... will be free from defects in material and workmanship for a period of one year from the date of shipment thereof or the product s total rated life whichever first occurs Within the warranty period we shall repair or replace such products which are returned to us with shipping charges prepaid and which are determined by us to be defective This warranty will not apply to any product which has been ...

Reviews: