18
Chapter 5. Machine installation
EN
5.1. Transport and positioning
Handle with great care during transport and positioning!
Before any movement, make sure that the lifting means is suitable for the load to be lifted!
mod. RP40 – RP55
Cut the strap with scissors make sure you protect your eyes by
wearing glasses and withdraw the cardboard. Remove the screws and
any plate intended to fasten the machine to the pallet.
If you have purchased the legs:
Remove the box containing the legs.
Raise the machine using a fork lift and fit the 4 legs using the screws
provided.
Cut the strap to release the upper hood.
If you have purchased the waste rewinder:
Unpack the waste rewinder and position it as indicated in the instructions
provided.
mod. RP85
Cut the strap with scissors make sure you protect your eyes by
wearing glasses and withdraw the cardboard. Remove the screws and
any plate intended to fasten the machine to the pallet.
Lift the machine by means of a fork lift truck and place it on the floor.
Cut the strap to release the upper hood.
5.2. Environmental conditions
Place the machine level on the floor in a suitable environment free from humidity, gases, explosives, combustible materials. The
machine may only be installed on smooth, flat non-inflammable surfaces.
Leave a minimum space of 0,5m around the machine so that not to obstruct air inlets
Once the correct position is achieved, lock the machine by means of the wheel brakes.
Working environment conditions:
Temperature from + 5°C to + 40°C
Relative humidity from 30% to 90%, without condensation.
The lighting of the operation room shall comply with the laws in force in the country where the machine is installed. However, it shall be
uniform and allow good visibility in order to safeguard the operator’s safety and health.
MACHINE PROTECTION FACTOR = IP20
THE AIRBORNE NOISE MADE BY THE MACHINE IS LOWER THAN 70 dB(A)
5.3. Electrical connections
Voltage (V): see data on plate
Frequency (Hz): see data on plate
Maximum absorbed power (W): see data on plate
Maximum absorbed current (A): see data on plate
Note: when contacting the Manufacturer, always indicate the model and the serial number specified on the
plate on the rear part of the machine.
OBSERVE HEALTH AND SAFETY REGULATIONS!
If the machine is not equipped with the power supply plug, use a plug that is suitable for the voltage and
amperage values described by the rating plate and that can comply with the rules in force in the installation
country.
GROUNDING OF THE UNIT IS OBLIGATORY!
Before making electrical connections, make sure the mains voltage matches the one on the plate on machine
rear and that the ground contact complies with the safety rules in force.
In case of doubts about the mains voltage, contact the local power supply company.
Insert the plug on the cable from machine electrical cabinet in a mains power supply socket that can be
reached easily by the operator.